• 제목/요약/키워드: transient response characteristic

검색결과 104건 처리시간 0.032초

DC서보계에서 2중신경망을 이용한 확대 PID 제어기의 위치제어 (The Position Control Of Expended PID Controller Using Double-Layers Neural Network In DC Servo System)

  • 이정민;하홍곤
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 하계종합학술대회논문집
    • /
    • pp.105-108
    • /
    • 2000
  • Many control techniques have been proposed in order to improve the control performance of discrete-time domain control system. In the position control system using a DC servo motor as a driver, the response-characteristic of system is controlled by the PID controller. In the PID control system, the transient response characteristic is more increased and settling time gets longer if gains of PID controller are unsuitable. In this paper, therefore, a expended PID control system is constructed by inserting a pre-compensator at output terminal of PID controller. It is implemented by using the double layers neural network. Form the results of computer simulation in the proposed control algorithm, its usefulness is verified.

  • PDF

인덕턴스 변화에 강인한 계통연계형 인버터의 복소 벡터 전류제어기 (Complex Vector Current Control of Grid Connected Inverter Robust for Inductance Variation)

  • 이태진;조종민;신창훈;차한주
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1648-1654
    • /
    • 2016
  • This paper analyzes complex vector current control for the enhanced cross-coupling compensation in accordance with parameter variation in grid-connected inverter system, and verifies through simulation and experiment. Complex vector current control is performed in the synchronous reference frame through d-q transformation. It generates cross-coupling components with rotating nominal angular frequency. In general, cross-coupling elements are compensated by decoupling terms added to output of conventional decoupling PI controller. But, it is impossible to compensate them perfectly which transient response is especially deteriorated such as large overshoot and slow tracking, when variation of grid impedance or measurement error occurs. However, complex vector current control can improve stability and response characteristic of current control regardless of the situation as before. Decoupling controller and complex vector controller are represented through complex forms, and these controllers are analyzed by using frequency response in s-domain, respectively. It is verified that complex vector controller has more superior response characteristic than decoupling controller through MATALB, PSIM and experimental in 5kW grid-connected inverter when L filter parameter is varied from 1.1mH to increase double, 2.2mH.

1축 자기 부상 장치의 비선형 슬라이딩 모드 강인 제어 (Nonlinear sliding mode robustness control of Axial Electro-Magnetic suspension system)

  • 고유석;송창섭;이강원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.474-477
    • /
    • 1995
  • In this paper, the nonlinear model of axial electro-magnetic suspension(EMS) system is presented. The characteristic of attracyion force is analyzed by FEM. Some simulation is given to compare the sliding mode control based on the input-output linearization with the classical linear control using Taylor approximation. Real result of regulating control, transient response comparison, and robustness control with disturbance using the sliding mode method is presented.

  • PDF

ATP Draw를 이용한 전력계통 설비의 모의 및 특성분석 (Simulation and Characteristic Analysis Using ATP Draw for Power System Equipments)

  • 하체웅;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1227-1229
    • /
    • 1999
  • The ATP Draw is a graphical mouse-driven preprocessor to ATP on the Windows Platform. User can build a graphical picture of the electric circuit by selecting components from menus. In this paper, ATP Draw is used to analyze power transformer transient characteristics and lightning overvoltage phenomenon in underground transmission cables. The results obtained by simulations will be used to identify the response of the digital protection algorithms in power system equipment

  • PDF

가변주파수 3상 정현파 신호의 최대전압 검출기 (A Peak Detector for Variable Frequency Three-Phase Sinusoidal Signals)

  • 김홍렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.210-215
    • /
    • 1999
  • The proposed detector is consists of three-phase sinusoidal signal generator and peak detector. This peak detector can detect the peak voltage value at the state of variable frequency. In experi-ment three-phase sinusoidal signals are generated from D/A converter using IBM PC and deliv-ered to the peak detector. Each signals are squared by multiplier and summed up Peak value is the square root of summed value extracted by square root circuit.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구 (Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator)

  • 김재문;김양수
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

Transient Response of Optically-Controlled Microwave Pulse through Open-Ended Microstrip Lines

  • Kim, Yong K.;Kim, Jin-Su;Park, Kyoung-Su
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.236-240
    • /
    • 2004
  • In this paper we examine the reflection characteristics of dielectric microstrip lines with open-ended termination containing an optically induced plasma region, which are analyzed by the assumption that the plasma is distributed homogeneously in laser illumination. The characteristics impedances resulting from the presence of plasma are evaluated by the transmission line model. To estimate theoretically the characteristic response of identical systems in the time domain, the Fourier transformation method is evaluated. The reflection characteristics of time and frequency response in microwave systems have been calculated using an equivalent circuit model.

Transient Response of Optically-Controlled Microwave Pulse through an Open-Ended Microstrip Lines

  • Kim, Jin-S.;Kim, Yong-K.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1187-1190
    • /
    • 2004
  • In this paper we analyze the reflection characteristics of a dielectric microstrip line with an open-end termination containing optically induced plasma region, which are analyzed by the assumption that the plasma is distributed homogeneously in the laser illumination. The characteristics impedances resulting from the presence of plasma are evaluated the transmission line model. To estimate theoretically the characteristic response of same systems in the time domain, the Fourier transformation method is evaluated. The reflection characteristics of time response in microwave systems have been calculated.

  • PDF

Photoswitching Characteristics of Biodevice Consisting of Chlorophyll $\alpha$ Langmuir-Blodgett Film

  • Nam, Yun-Suk;Choi, Jeong-Woo;Lee, Won-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권5호
    • /
    • pp.1038-1042
    • /
    • 2004
  • The photoelectric responses of a biodevice consisting of chlorophyll $\alpha$ Langmuir-Blodgett film were investigated. Chlorophyll $\alpha$ Langmuir-Blodgett films were deposited onto ITO and Au coated glass. To confirm film formation, surface analysis of chlorophyll $\alpha$ Langmuir-Blodgett film was carried out by measurement using atomic force microscopy. The metal/insulator/metal structured biodevice was constructed by depositing aluminum onto the chlorophyll $\alpha$ Langmuir-Blodgett film surface. To investigate the photoelectric response, the current-voltage characteristic was measured by the conducting metal tip. The photoswitching function and transient photovoltage characteristics of the proposed device were measured by irradiation with Ar ion laser and $N_2$ pulse laser, respectively. This research suggested that the proposed biodevice consisting of chlorophyll $\alpha$ could be applied to the molecular scale biosensor and/or bioelectronic device.

PWM 방식 벅 컨버터의 빠른 과도응답 기술 (Fast Transient Response Techniques for PWM Buck Converter)

  • 석진민;서정덕;공배선
    • 전기전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.103-106
    • /
    • 2016
  • PWM 벅 컨버터는 3형 오차 보상기를 주로 사용하고 있다. 이 오차 보상기는 낮은 슬루율을 갖게 하는 큰 커패시터로 인해, 부하 전류의 과도응답이 발생하였을 때 부하 전압에 의도하지 않은 큰 오버슈트와 언더슈트를 발생시킨다. 또한 기준전압을 변화시켰을 때의 변화에도 느리게 응답한다. 전원장치의 효율적인 사용을 위해 다양한 부하 전류와 전압이 요구되고 있고, PWM 벅 컨버터 역시 부하 전류 변화와 기준 전압 변화에 따른 부하 전압의 빠른 응답특성을 가져야 한다. 본 논문은 PWM 벅 컨버터의 응답시간을 늘이기 위한 여러 가지 빠른 과도응답 기술들의 동작 방식과 이들 방법이 갖고 있는 장점, 한계점들을 소개한다.