봉형접지전극의 임펄스임피던스 도출 (Impulse Impedance of a Rod type Grounding Electrode)

  • 김왕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.578-580
    • /
    • 1993
  • The impulse impedence of grounding system must be accurately evaluated for a safe grounding design. However, a calculation nettled of the impulse impendence of a horizontal grounding electrode has not been established yet. This paper presents a method to compute the impulse impedance of a rod type grounding electrode and deals with the analysis of the transient characteristics on the electrodes.

  • PDF

주파수 영역에서 봉상전극의 접지임피던스 특성 (Ground ing Impedance Characteristics of Ground Rods in frequency Domain)

  • 이형수;심건보;김경철;최종기;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.248-253
    • /
    • 2005
  • Although DC ground resistance is a good index of grounding performance for grounding electrodes, it does not reflect the grounding performance during transient state. Besides, impulse ground impedance, which is defined by a ratio of the peak value of transient ground potential rise to the peak value of impulse current, cannot be an absolute index due to its dependence on impulse current shape. In this paper, ground impedance of various rod-type ground electrodes has been measured in frequency domain ranging from 1 Hz to hundreds of kHz. Equivalent circuit models of the ground rod have been identified from the measured values of ground impedance in frequency domain.

  • PDF

High Frequency Grounding Impedances of Vertically-Driven Ground Rods

  • Kim, Tae-Ki;Lee, Bok-Hee;Jeon, Duk-Kyu
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.41-48
    • /
    • 2009
  • Grounding impedance depends on the frequency of current flowing into a grounding system lightning in particular has a broad frequency spectrum from some tens of Hz to a few MHz. So the grounding impedance related to transient currents such as lightning should be measured. In this paper, the grounding impedances of vertically-driven ground rods of 10, 30 and 48[m] long are measured and analyzed as functions of the frequency of injected current and the feeding point. As a result, the longer the ground rod is, the lower the steady-state ground resistance is. However the grounding impedance of a vertically-driven ground rod at a high frequency is significantly increased. It is not always true that low grounding impedance follows from a low steady-state ground resistance. It is important to evaluate the high frequency performance of grounding systems for protection against lightning.

심매설 접지전극의 전류인가위치에 따른 과도접지임피던스 특성 (Transient impedance characteristics according to the injection position of deep-driven ground rods)

  • 이복희;이봉;이수봉;이승주;전병욱;엄주홍;조성철;이태형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 2008
  • This paper presents the behaviors of transient and conventional grounding impedances of a deep-driven ground rods associated with the injection point of lightning impulse currents. The transient impedance of deep-driven ground rods under lightning impulse currents were higher than the static ground resistance. The transient grounding impedances strongly depend on the injection point and size of grounding electrodes and the rising time of impulse current. Reduction of ground system inductance is an important factor to lightning surge protection.

  • PDF

임펄스전압에 의한 동심원통형 전극계에서 토양 이온화특성 분석 (Analysis of Soil lonization Characteristics in Concentric Cylindrical Electrode System under Impulse Voltages)

  • 김회구;박건훈;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.32-39
    • /
    • 2008
  • 본 논문은 뇌임펄스전압에 의한 토양의 이온화 현상과 모델접지시스템의 과도적 특성에 관련된 파라미터에 관한 것으로 건조 모래와 습한 모래에 대한 이온화 특성을 치수가 다른 동심원통형 전극계의 실험 용기를 이용하여 연구하였다. 결과로써, 높은 임펄스전압이 인가된 모래의 비선형 전기적 특성은 이온화 과정에 의해 발생하였다. 모래의 과도임피던스는 수분의 함유량과 인가임펄스전압의 크기에 의존하며, 수분의 함유량과 인가전압의 크기의 증가에 따라 접지임피던스는 감소하였다. 본 연구결과는 뇌서지에 대하여 우수한 성능을 가지는 접지시스템의 설계에 유용한 정보가 될 것이다

가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

탄소접지극 접지임피던스의 주파수의존성과 과도응답특성의 해석 (Analysis of Transient Response Behavior and Frequency-Dependent Ground Impedances of the Carbon Ground Electrodes)

  • 이복희;이강수;김유하;엄상현
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • This paper presents transient response behavior and frequency-dependent ground impedance of a single carbon ground electrode. The ground impedance of the carbon ground electrode was measured as a function of frequency of injected currents and simulated by using the distributed parameter circuit model with due regard to the frequency-dependent soil parameters, and the transient response behavior of the carbon ground electrode against impulse currents were investigated. As a consequence, the frequency-dependent ground impedance of the carbon ground electrode showed the capacitive behavior, that is, the ground impedance decreases with increasing the frequency of injected currents and lowers at the fast front time of impulse current. It was found that the carbon ground electrode is effective in grounding system for lightning protection. The ground impedance simulated with due regard to the frequency-dependent soil parameters was in good agreement with the measured data. The adequacy of the simulation technique and the distributed parameter circuit model for the carbon ground electrode was verified. It is expected that the simulation methodology, which analyzes the frequency-dependent ground impedance of the carbon ground electrode proposed in this work, can be used in the design of a grounding system for protection against lightning.

봉상접지극의 임펼스 전류에 대한 과도접지임피던스 특성 (Characteristics of Transient Grounding Impedances of Rod Electrodes)

  • 이복희;박종순;양정재;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1645-1647
    • /
    • 1997
  • Electronic circuits are becoming more vulnerable owing to the development of integrated circuit. Computer and info-communication facilities are very sensitive to surges caused by lightning, and they can suffer a malfunction and damage. Recent concern about damage and upset caused by transient overvoltages has focused on surge protection. The most important parameter in surge protection is the transient grounding impedance. In this paper, the transient grounding impedances of a rod electrode have been measured under impulse current waves. Z-t, Z-i and V-i characteristics of the grounding electrode in according to the length of the grounding lead wire were obtained and analyzed.

  • PDF

Critical Length Estimation of Counterpoise Subjected to Lightning Stroke Currents

  • Lee, Bok-Hee;Yoo, Yang-Woo;Kim, Jong-Ho
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.106-113
    • /
    • 2011
  • The conventional grounding impedance of a counterpoise is calculated as a function of the length of the counterpoise by use of the distributed parameter circuit model with an application of the EMTP(Electromagnetic Transient Program). The adequacy of the distributed parameter circuit model is examined and verified by comparison of the simulated and the measured results. The conventional grounding impedance of the counterpoise is analyzed for the first short stroke and subsequent short stroke currents. As a result, the simulated results show that the minimum conventional grounding impedance gives at a specified length of the counterpoise. The shorter the time taken to reach the peak of injected currents, the shorter the length of the counterpoise having the minimum conventional grounding impedance. We also present the critical lengths of the counterpoise for short stroke currents as a function of soil resistivity. Based on these results, it is necessary to compute the length of the counterpoise in a specified soil resistivity which satisfies both the low conventional grounding impedance requirement whilst also providing a suitable ground resistance in order to obtain an economical design and installation of the counterpoise.

주파수 및 시간영역 특성시험에 의한 봉형 접지전극의 과도 접지임피던스 모델링에 관한 연구 (A Study on the Transient Ground Impedance Modeling for Rod-type Grounding Electrodes by Frequency and Time Domain Characteristic Tests)

  • 김종욱;김경철;신판석;최종기;최선규;김동명
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.133-141
    • /
    • 2010
  • 접지시스템은 전기설비의 기준 전위점을 확보할 뿐만 아니라 대지에 낮은 저항으로 고장전류나 과도전류를 흐르게 한다. 주파수에 대한 함수로 접지임피던스는 고장이나 과도전류가 넓은 범위의 주파수 성분을 포함하기 때문에 접지성능을 평가하는데 중요한 역할을 한다. 동봉과 콘크리트봉은 배전계통에서 가장 많이 쓰이고 있는 접지전극이다. 본 논문에서는, 주파수영역과 시간영역의 특성시험으로 동봉과 콘크리트봉의 접지임피던스를 측정하였다. 접지임피던스의 등가 전달함수 모델은 측정된 데이터를 이용하여 ARMA 기법으로 모델링 되었고, 규약 접지임피던스로 비교하여 평가하였다.