• Title/Summary/Keyword: transient conditions

Search Result 1,113, Processing Time 0.025 seconds

Investigation on the Allowable Transient Power Levels to Maintain the Mechanical Integrity of the 17$\times$17 KOFA Fuel Rod During the ANS Conditions I and II (ANS과도조건 I 및 II에서 17x17 KOFA 핵연료봉의 기계적 건전성이 유지되는 과도상태 허용 출력준위에 관한 연구)

  • Lee, Chan-Bock;Kim, Ki-Hang;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.119-125
    • /
    • 1994
  • Transient power level of the fuel rod is one of the key parameters for the transient fuel behavior. Through the analysis of the fuel performance data bases and sensitivity analyses of such parameters as rod power history, fast neutron flux, fuel enrichment and cycle length, which can affect the transient fuel behavior, a methodology generally applicable to find the allowable transient power level during the ANS Conditions I and II below which the mechanical integrity of the fuel rod is maintained was derived, and allowable transient power levels for the 17$\times$17 KOFA fuel rod have been determined as a function of the burnup. With the introduction of this methodology, design analysis of the transient fuel behavior currently being calculated every cycle can be replaced by the simple check of the peak transient power level achievable during the cycle, and an operational flexibility of the reactor can be obtained by allowing higher transient power level up to 689.5 w/cm at low burnup range than current maximum allowable transient power level, 591 w/cm for the 17$\times$17 KOFA fuel.

  • PDF

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF

Influence of Droplet Drag Models on Diesel Spray Characteristics under Ultra-High Injection Pressure Conditions (극초고압 조건에서 디젤 분무 특성에 미치는 액적 항력 모델의 영향)

  • Ko, Gwon-Hyun;Lee, Seong-Hyuk;Lee, Jong-Tai;Ryou, Hong-Sun
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.42-49
    • /
    • 2004
  • The present article investigates the influence of droplet drag models on predictions of diesel spray behaviors under ultra-high injection pressure conditions. To consider drop deformation and shock disturbance, this study introduces a new hybrid model in predicting drag coefficient from the literature findings. Numerical simulations are first conducted on transient behaviors of single droplet to compare the hybrid model with earlier conventional model. Moreover, using two different models, extensive numerical calculations are made for diesel sprays under ultra-high pressure sprays. It is found that the droplet drag models play an important role in determining the transient behaviors of sprays such as spray tip velocity and penetration lengths. Numerical results indicate that this new hybrid model yields the much better conformity with measurements especially under the ultra-high injection pressure conditions.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

Probabilistic Assessment of Total Transfer Capability Using SQP and Weather Effects

  • Kim, Kyu-Ho;Park, Jin-Wook;Rhee, Sang-Bong;Bae, Sungwoo;Song, Kyung-Bin;Cha, Junmin;Lee, Kwang Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1520-1526
    • /
    • 2014
  • This paper presents a probabilistic method to evaluate the total transfer capability (TTC) by considering the sequential quadratic programming and the uncertainty of weather conditions. After the initial TTC is calculated by sequential quadratic programming (SQP), the transient stability is checked by time simulation. Also because power systems are exposed to a variety of weather conditions the outage probability is increased due to the weather condition. The probabilistic approach is necessary to evaluate the TTC, and the Monte Carlo Simulation (MCS) is used to accomplish the probabilistic calculation of TTC by considering the various weather conditions.

Docosahexaenoic acid reduces adenosine triphosphate-induced calcium influx via inhibition of store-operated calcium channels and enhances baseline endothelial nitric oxide synthase phosphorylation in human endothelial cells

  • Vu, Thom Thi;Dieterich, Peter;Vu, Thu Thi;Deussen, Andreas
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.5
    • /
    • pp.345-356
    • /
    • 2019
  • Docosahexaenoic acid (DHA), an omega-3-fatty acid, modulates multiple cellular functions. In this study, we addressed the effects of DHA on human umbilical vein endothelial cell calcium transient and endothelial nitric oxide synthase (eNOS) phosphorylation under control and adenosine triphosphate (ATP, $100{\mu}M$) stimulated conditions. Cells were treated for 48 h with DHA concentrations from 3 to $50{\mu}M$. Calcium transient was measured using the fluorescent dye Fura-2-AM and eNOS phosphorylation was addressed by western blot. DHA dose-dependently reduced the ATP stimulated $Ca^{2+}$-transient. This effect was preserved in the presence of BAPTA (10 and $20{\mu}M$) which chelated the intracellular calcium, but eliminated after withdrawal of extracellular calcium, application of 2-aminoethoxy-diphenylborane ($75{\mu}M$) to inhibit store-operated calcium channel or thapsigargin ($2{\mu}M$) to delete calcium store. In addition, DHA ($12{\mu}M$) increased ser1177/thr495 phosphorylation of eNOS under baseline conditions but had no significant effect on this ratio under conditions of ATP stimulation. In conclusion, DHA dose-dependently inhibited the ATP-induced calcium transient, probably via store-operated calcium channels. Furthermore, DHA changed eNOS phosphorylation suggesting activation of the enzyme. Hence, DHA may shift the regulation of eNOS away from a $Ca^{2+}$ activated mode to a preferentially controlled phosphorylation mode.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.

An Experimental Study on Transient Characteristics of PEM Fuel Cell Stack (PEM 연료전지 스택의 과도상태 출력특성에 관한 실험적 연구)

  • Kim, Hyun-il;Hwang, Jae-Soon;Chung, Tae-Yong;Shin, Dong-Hoon;Nam, Jin-Hyun;Kim, Young-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2003-2008
    • /
    • 2007
  • The transient power characteristics of a PEM fuel cell stack was experimentally studied using a commercial 1.2kW PEM fuel cell ($Nexa^{TM}$ Power Module, Ballard Power System Inc.). The conditions in PEM fuel cell stack such as temperature and water content change rather slowly because of their large heat capacity and long channel length, which results in long transient time to converge to a steady state. The steady characteristics of the PEM fuel cell module was determined first, followed by the measurement of its transient characteristics upon stepwise and continuous load current changes. During the stepwise current change from 5A to 25A, the output voltage initially decreased below the steady voltage and then increased gradually. Similar behavior was also observed for the stepwise current change from 25A to 5A. This transient behavior is explained with reference to the evolution of the temperature and water content of the PEM fuel cell stack.

  • PDF

Improvement of the Transient Response by Partially Compensating Initial Values of Digital Controllers (디지털 제어기의 부분적 초기값 보상을 통한 천이 응답 특성 향상)

  • Doh, Tae-Yong;Ryoo, Jung Rae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.285-289
    • /
    • 2013
  • In switching from the track-seeking or track-jumping control mode to track-following control mode in hard disk drives or optical disk drives, initial values of the feedback controller are tuned to improve the transient response. In general, all the initial values of the controller have been compensated for this purpose. In this paper, by partially compensating initial values of digital controllers, we achieve a good performance of the transient response. In the proposed method for IVC (Intial Value Compensation), LMIs (Linear Matrix Inequalities) are used, which includes conditions for improving the performance of the transient response such as reducing a tracking error and control efforts. We obtain optimal initial values of the controller by solving an optimization problem with constraints represented by only one LMI. Although initial values of the controller are partially compensated, we can show that not only a sufficient performance of the transient response is obtained but also control efforts are diminished. The feasibility of the method is verified by simulation studies.

Rotordynamic Transient Analysis of Vertical Sea Water Lift Pump for FPSO Deep Well (FPSO 심정용 수직 해수펌프의 로터다이나믹 과도해석)

  • Kim, Byung-Ok;Yang, Sung-Jin;Lee, Myung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.69-74
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for the vertical rotor system as development of vertical sea water lift pump for FPSO deep well. In a vertical rotor system, since linearized stiffness and damping coefficients of fluid film bearing are no longer be valid, hence the transient response analysis considering a fluid film force for every journal position in the bearing needs to be required. In this study, the transient response analysis of the proposed vertical pump rotor system was carried out in dry-run and wet-run conditions, respectively. The results show that orbital vibration responses of the rotor system remain stable at rated speed and thereby operating reliability of the vertical rotor system is confirmed. To overcome complexity of calculation pr ocedure and time consuming calculation of transient analysis, the calculating technique of steady-state response analysis is also proposed. The results of steady-state response obtained by applying the proposed technique to the rotor system are good agreement with the reference results, that is, transient responses.