선로정수에 대한 선택적인 고유치감도 기법의 개발 (Development of Selective Eigen-Sensitivity Techniques for Line Parameter)

  • 심관식;남해곤;김용구;송성근;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1299-1301
    • /
    • 1999
  • This paper describes a initial screening methods for weak line selection using sensitivity matrix. The elements of sensitivity matrix for line suceptance have 1 or -1, 0. From this property of sensitivity matrix, the eigen-sensitivity for line suceptance can be computed very simply and selected weak line for small signal stability or transient stability. The proposed algorithm is applied to small signal stability of New England 39-bus system and also applied to voltage stability of New England 30-bus system too.

  • PDF

대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg법 (Hessenberg Method for Small Signal Stability Analysis of Large Power Systems)

  • 남해곤;송성근;심관식;문채주;김동준;문영환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.168-176
    • /
    • 2000
  • This paper presents the Hessenberg method, a new sparsity-based small signal stability analysis program for large interconnected power systems. The Hessenberg method as well as the Arnoldi method computes the partial eigen-solution of large systems. However, the Hessenberg method with pivoting is numerically very stable comparable to the Householder method and thus re-orthogonalization of the krylov vectors is not required. The fractional transformation with a complex shift is used to compute the modes around the shift point. If only the dominant electromechanical oscillation modes are of concern, the modes can be computed fast with the shift point determined by Fourier transforming the time simulation results for transient stability analysis, if available. The program has been successfully tested on the New England 10-machine 39-bus system and Korea Electric Power Co. (KEPCO) system in the year of 2000, which is comprised of 791-bus, 1575-branch, and 215-machines. The method is so efficient that CPU time for computing five eigenvalues of the KEPCO system is 3.4 sec by a PC with 400 MHz Pentium IIprocessor.

  • PDF

온라인 전력계통 안정도 진단을 위한 선로 선정 방안 (Identification of Correlative Transmission Lines for On-Line Stability Diagnosis)

  • 조윤성;장길수;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.3-6
    • /
    • 2001
  • Power system stability is correlated with system structure, disturbances and operating conditions. and power flows in transmission lines are closely related with those conditions. This paper discusses a methodology to identify crucial transmission lines for stability diagnosis with respect to transient stability and small-signal stability. On-line monitoring of the selected lines enables to predict system stability in real-time. Also, a Procedure to make a priority list of monitored transmission lines using contingency analysis. The procedure is applied to the PSS/E test system. and it shows capabilities of the proposed method.

  • PDF

Korean Power System Security Analysis Using Benchmark Systems

  • Cho Yoon-Sung;Jang Gilsoo
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.207-213
    • /
    • 2005
  • This paper deals with the development of benchmark systems based on the Korea Electric Power Corporation (KEPCO) system. A novel procedure for constructing a dynamic equivalent system of the KEPCO system is proposed. By using such a system, various scenarios can be simulated and compared with the original system. The results of the simulation show the benefits of the proposed equivalent system and its validity is confirmed by applying it to the KEPCO system.

서인천 복합화력 발전소의 PSS 파라메터 Tuning (Field test Results for PSS Parameter Tuning in Seo-Incheon Power Plant)

  • 신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1143-1146
    • /
    • 1998
  • Static excitation systems with high gain and fast response times greatly aid transient stability. but at the same time tend to reduce small signal stability. The objective of the power system stabilizer(PSS) control is to provide a positive contribution to damping of the generator rotor angle swings, which are in a broad range of frequencies in the power system. Therefore, this paper shows the field test results for the GE's EX2000 PSS tuning on units at Seo-Incheon power plant. The test is to verify that the PSS response meets GE's design, criteria. The responses of generator terminal voltage, active power, field voltage and current were analyzed and PSS gain was tuned by 10 finally.

  • PDF

PMU 데이터를 이용한 저주파 진동분석 연구 (A Study on the Low Frequency Oscillation Using PMU Measurement Data)

  • 김용학;남수철;고백경;강성범;심관식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권3호
    • /
    • pp.245-252
    • /
    • 2020
  • It is very important to evaluate on/off-line stability to operate the power system stably and economically. Until now, we have continuously secured the operation reliability of the power system through the evaluation of transient, voltage and small signal stability. This paper proposes that it is possible to operate in KWAMS by applying the multi-section analysis and subspace methods and verifying the reliability of the algorithms to directly estimate the dominant oscillation mode of the power system from the signal waveform acquired from the phasor measurement units. In addition, this paper shows that the dominant oscillation mode can be detected from real-time measurement data in power systems. Therefore, if we can monitor the state of the power system in real time, it is possible to avoid a large-scale power outage by knowing the possibility of the power system accident in advance.

HVDC 연계 시스템의 전력계통 안정화 장치와 전력변환기 적정 파라미터 선정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer and Power Converters for HVDC Linked System)

  • 조의상;김경철;최홍규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.65-72
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. Control of HVDC converter and inverter are used a constant current loop. Proper parameters of PI controllers are obtain based on the Root-locus technique in other to have sufficient speed and stability margin to cope with charging reference values and disturbance. The small signal stability arid transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the studycase system is adequately damped. Also the simulation results using the HVDC converter and inverter parameters obtained from this proposed method show proper current control characteristics. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

HVDC 연계 시스템의 전력계통 안정화 장치의 적정 파라메터 선정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer for HVDC Linked System)

  • 김경철;최홍규;최병숙;강태은;고영곤
    • 조명전기설비학회논문지
    • /
    • 제15권5호
    • /
    • pp.81-89
    • /
    • 2001
  • 전력 계통 안정화 장치는 전력시스템에 외란이 발생했을 때 저주파수 동요현상을 효과적으로 저감하는 역할을 한다. 본 논문은 제주-해난 HVDC로 연계된 전력시스템에 설치된 PSS의 적정 파라메커 선정이론을 다루었다. 사용한 알고리즘은 위상지연을 적절한 극좌표 이동법으로 보상하고 설정된 댐핑계수가 되도록 이득계수를 구하는 방법이다. PSS 효과를 검증하기 위해 동태 및 과도안정도를 PSS 설치 전과 후로 비교하였다. MATLAB을 근거로 한 PST 프로그램을 사용하여 사례연구 시스템에 적용한 시뮬레이션 결과는 PSS를 설치하므로써 전력시스템이 안정화되어 만족할 만큼의 댐핑효과를 보았다.

  • PDF

독립운전 모드에서 가상 인덕터를 활용한 대용량 인버터 병렬운전을 위한 드룹제어 (Droop Method for High-Capacity Parallel Inverters in Islanded Mode Using Virtual Inductor)

  • 정교선;임경배;김동환;최재호
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.81-90
    • /
    • 2015
  • This paper investigates the droop control-based real and reactive power load sharing with a virtual inductor when the line impedance between inverter and Point of Common Coupling (PCC) is partly and unequally resistive in high-capacity systems. In this paper, the virtual inductor method is applied to parallel inverter systems with resistive and inductive line impedance. Reactive power sharing error has been improved by applying droop control after considering each line impedance voltage drop. However, in high capacity parallel systems with large output current, the reference output voltage, which is the output of droop controller, becomes lower than the rated value because of the high voltage drop from virtual inductance. Hence, line impedance voltage drop has been added to the droop equation so that parallel inverters operate within the range of rated output voltage. Additionally, the virtual inductor value has been selected via small signal modeling to analyze stability in transient conditions. Finally, the proposed droop method has been verified by MATLAB and PSIM simulation.

통신위성 배터리 충,방전기 설계 및 해석 (Design and Analysis of a Battery Charge and Discharge Regulator of Communication Satellite)

  • 최재동
    • 한국항공우주학회지
    • /
    • 제31권7호
    • /
    • pp.118-126
    • /
    • 2003
  • 본 연구에서는 모듈형태의 배터리 충-방전기가 정상상태뿐만 아니라 과도상태에서 예기치 못한 결함이 발생할지라도 실패 없이 전원을 공급하는 것이 가능한 병렬형 양방향 컨버터로 설계되어졌다. 컨버터 모듈은 안정성, 성능 및 고신뢰성을 얻기 위해 독립적인 제어가 가능하도록 설계되었으며, 제어기를 위해 사용된 평균전류모드방식은 노이즈 면역, 빠른 응답 및 평균전류 신호 획득과 같은 장점을 갖는다. 병렬 연결된 배터리 충-방전기에 대한 등가모델이 제시되었으며, 충전연속모드, 방전연속/불연속 모드에 대한 전달함수가 분석되었다. 병렬 양방향 컨버터는 스텝 부하변화와 하나의 컨버터 모듈 실패에 대해 각각 수행되었다. 그리고 병렬 양방향 컨버터의 성능이 실험결과들을 통해 검증되었다.