• Title/Summary/Keyword: transformation method

Search Result 3,360, Processing Time 0.067 seconds

The Construction of Kinematic Survey System for the Efficiency of GPS Cadastral Survey (지적측량 효율성 향상을 위한 GPS 이동측량 시스템 구축)

  • 김경택;장지원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.389-398
    • /
    • 2002
  • As the necessity of land information has increased according to development of computer and Information-communication, people have been interested in the satellite measurement system that can update Cadastral and Geographical information rapidly and exactly. Most Cadastral base points which had limitation of measurement technology in the 1910s were less accurate and were destroyed through the Korean War. They also many problems in the process of reinstallation. So, they require the quick and correct method of measurement in re-equipment of a base point and a parcel based survey and so on. This study intends to present the GPS survey direction by understanding and analysing all sorts of problems rising in case of applying the GPS to cadastral area in order to increase the efficiency of the GPS measurement, and also develop the GPS kinematic survey program to apply to the efficiency of a kinematic survey. As a result of research, I could confirm the accuracy of Cadastral base points in Kwangju area by using Korea GPS array and a base point, and could get the result similar to existent cadastral survey result with the coordinate conversion program of Cadastral technology research institute. We however have to pay our attention to the transformation of the plane coordinates because the difference between tens of cm and the existing result can outbreak according to the Gauss conformal double projection method. And, I could figure out the practicality of the developed GPS kinematic survey program, compared with common use program. I expect that it can be applied to the digital cadastral survey and the cadastral map renewal as well.

Investigation of the La1-x(Ca or Sr)xCrO3x=0 and 0.25) Interconnect Materials for High Temperature Electrolysis of Steam (고온수증기전기분해용 La1-x(Ca or Sr)xCrO3(x=0 and 0.25) 연결재 재료 연구)

  • Jeong, So-Ra;Kang, Kyoung-Soo;Park, Chu-Sik;Lee, Yong-Taek;Bae, Ki-Kwang;Kim, Chang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1135-1141
    • /
    • 2008
  • The $La_{1-x}(Ca\;or\;Sr)xCrO_3$(x=0 and 0.25) interconnect materials for high temperature electrolysis of steam were investigated in views of sinterability and electrical conductivity. $LaCrO_3$, $La_{0.75}Ca_{0.25}CrO_3$ (LCC), and $La_{0.75}Sr_{0.25}CrO_3$ (LSC) powders were synthesized by coprecipitation method. Crystal structure was confirmed by X-ray diffraction (XRD). The sintering characteristics were analyzed by relative density and scanning electron microscopy. The electrical conductivity was measured by a DC four probe method. From the analyses of relative densities, it was found that the doped $LaCrO_3$ showed better sinterability than $LaCrO_3$ and the those sinterability increased with decrease of those particle sizes. The XRD results at different sintering temperatures for LCC and LSC revealed that the sinterability is closely related to the second phase transformation, that is, the second phase melting above $1,300^{\circ}C$ for LCC and $1,400^{\circ}C$ for LSC significantly promotes the sinterability. In case of electrical conductivities of LCC and LSC, which had a similar relative density, LCC showed better electrical conductivity than LSC.

Feature-based Non-rigid Registration between Pre- and Post-Contrast Lung CT Images (조영 전후의 폐 CT 영상 정합을 위한 특징 기반의 비강체 정합 기법)

  • Lee, Hyun-Joon;Hong, Young-Taek;Shim, Hack-Joon;Kwon, Dong-Jin;Yun, Il-Dong;Lee, Sang-Uk;Kim, Nam-Kug;Seo, Joon-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.237-244
    • /
    • 2011
  • In this paper, a feature-based registration technique is proposed for pre-contrast and post-contrast lung CT images. It utilizes three dimensional(3-D) features with their descriptors and estimates feature correspondences by nearest neighborhood matching in the feature space. We design a transformation model between the input image pairs using a free form deformation(FFD) which is based on B-splines. Registration is achieved by minimizing an energy function incorporating the smoothness of FFD and the correspondence information through a non-linear gradient conjugate method. To deal with outliers in feature matching, our energy model integrates a robust estimator which discards outliers effectively by iteratively reducing a radius of confidence in the minimization process. Performance evaluation was carried out in terms of accuracy and efficiency using seven pairs of lung CT images of clinical practice. For a quantitative assessment, a radiologist specialized in thorax manually placed landmarks on each CT image pair. In comparative evaluation to a conventional feature-based registration method, our algorithm showed improved performances in both accuracy and efficiency.

A Study on Trade Area Analysis with the Use of Modified Probability Model (변형확률모델을 활용한 소매업의 상권분석 방안에 관한 연구)

  • Jin, Chang-Beom;Youn, Myoung-Kil
    • Journal of Distribution Science
    • /
    • v.15 no.6
    • /
    • pp.77-96
    • /
    • 2017
  • Purpose - This study aims to develop correspondence strategies to the environment change in domestic retail store types. Recently, new types of retails have emerged in retail industries. Therefore, trade area platform has developed focusing on the speed of data, no longer trade area from district border. Besides, 'trade area smart' brings about change in retail types with the development of giga internet. Thus, context shopping is changing the way of consumers' purchase pattern through data capture, technology capability, and algorithm development. For these reasons, the sales estimation model has been shown to be flawed using the notion of former scale and time, and it is necessary to construct a new model. Research design, data, and methodology - This study focuses on measuring retail change in large multi-shopping mall for the outlook for retail industry and competition for trade area with the theoretical background understanding of retail store types and overall domestic retail conditions. The competition among retail store types are strong, whereas the borders among them are fading. There is a greater need to analyze on a new model because sales expectation can be hard to get with business area competition. For comprehensive research, therefore, the research method based on the statistical analysis was excluded, and field survey and literature investigation method were used to identify problems and propose an alternative. In research material, research fidelity has improved with complementing research data related with retail specialists' as well as department stores. Results - This study analyzed trade area survival and its pattern through sales estimation and empirical studies on trade areas. The sales estimation, based on Huff model system, counts the number of households shopping absorption expectation from trade areas. Based on the results, this paper estimated sales scale, and then deducted modified probability model. Conclusions - In times of retail store chain destruction and off-line store reorganization, modified Huff model has problems in estimating sales. Transformation probability model, supplemented by the existing problems, was analyzed to be more effective in competitiveness business condition. This study offers a viable alternative to figure out related trade areas' sale estimation by reconstructing new-modified probability model. As a result, the future task is to enlarge the borders from IT infrastructure with data and evidence based business into DT infrastructure.

Induction of the High Order Calibration Equation of Metal Oxide Semiconductor Gas Sensors (산화물 반도체식 가스센서의 입출력 고차 캘리브레이션 방정식 도출)

  • Park, Gyoutae;Kim, Kangmin;Lee, Hyeonggi;Yoon, Myeongsub
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.44-49
    • /
    • 2020
  • In this paper, a measuring circuit is designed through analyzing manufacture specification of the sensor based on MOS. And the best input-output polynomial are induced that really gas sensors are used in gas safety management industrial fields. Response characteristics of a MOS gas sensor is analysed by through sensor's output voltages are measured after standard gases with six kinds of concentrations are manufactured and are injected to the sensor. A lookup table is created by relations of sensor's output voltages by injecting gases with other concentrations. Because data of the formed lookup table are equal interval, a polynomial can be induced of method of approximation function. So the 5th polynomial of input-output for a sensor is defined, coefficients are calculated by using least squares method, and the 5th polynomial is completed for representing characteristics of the sensor. If the proposed polynomial is applied to gas leak detectors, an inverse transformation of polynomial and programing of array codes are recreated. In this research, polynomial is implemented with array types that intervals of values of a lookup table are one-fifth sampled and interpolated. The performance of proposed 5th calibration equation is verified that errors are reduced than a linear expression when tests are performed by measurement of concentrations against injection of standard gases.

Fabrication of Zirconium Titanate Thin film from Layer-by-Layer Structure of Primitive Oxides prepared by PRTMOCVD (PRTMOCVD 법을 통한 단성분계 산화막의 적층형 구조로부터 Zirconium Titanate 박막의 제조)

  • Song, Byung-yun;Kwon, Yong Jung;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.378-383
    • /
    • 2007
  • A novel fabrication method for the multi-component metal oxides such as zirconium titanate($Zr_xTi_{1-x}O_2$) has been suggested, which would yield the uniform film characteristics and control the film composition at relatively low process temperature. The method has the basic concept that firstly layer-by-layer structure is constructed with the primitive oxide layers, which are components of the desired multi-component oxides, and secondly the film is annealed at appropriate thermal conditions for the transformation to a single-phase multi-component oxides. In this study, PRTMOCVD(pulsed rapid thermal metalorganic chemical vapor deposition) possessing the superior thickness controllability was introduced to prepare $ZrO_2$ and $TiO_2$ thin film for zirconium titanate. Single-phase zirconium titanate thin films have been prepared successfully by the interdiffusion of oxide multilayers having several alternating layers of $ZrO_2$ and $TiO_2$. The Zr/Ti ratio of zirconium titanate could be controlled easily by altering the thickness of $ZrO_2$ and $TiO_2$ thin film.

A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works - (모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 -)

  • Yoon, Jongsik;Shin, Dongwoo;Cha, Heesung;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.33-41
    • /
    • 2017
  • A modular specification is a contract document that specifies the requirements of production, transformation and installation in a modular construction. A problem of the currently used specification is that it does not guarantee the level of performance required by the modular construction and fails to accommodate unique characteristics of each construction because it widely uses the standard specification as it is. This study proposes a specification that reflects the unique feature of modular construction in order to improve the quality of modular construction. Research focuses on the leakage in waterproof and mechanical equipment because it is the area with the highest rate of defects. This study suggests ways to improve the modular specification as follows: 1)Descriptive specifying (following MasterFormat) 2)Propose leakage verification method and test clause 3) Reflect characteristic of modular construction. Proposed modifications to modular specification are reviewed by experts for validation and their opinion verifies suggested improvements as a way to secure the quality of modular construction and to promise characteristics of the modular specification. This improvement will be used for reference when writing construction project specification, which can be an important contract document, so that it could lower occurrence rate of the modular defects.

Characteristics of TiO2 and Ag/TiO2 optical thin film by Co-sputtering method (동시 스퍼터링법에 이용하여 제작한 TiO2와 Ag/TiO2 광학 박막의 특성)

  • Kim, Sang-Cheol;Hahn, Sung-Hong;Kim, Eui-Jung;Lee, Chung-Woo;Joo, Jong-Hyun;Kim, Goo-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.2
    • /
    • pp.168-173
    • /
    • 2005
  • Ag-doped $TiO_2$ thin films were prepared by RF magnetron co-sputtering method, and their physical and chemical properties were examined as a function of calcination temperature. XRD results showed that the crystallite size of Ag-doped films was smaller than that of the $TiO_2$ thin films. SEM results showed that the particle size of $Ag/TiO_2$ film was smaller and more uniform than pure $TiO_2$ film. The films had high transparency in the visible range. The films calcined at $600^{\circ}C$ were the anatase phase, and the films calcined at $900^{\circ}C$ were a mixture of anatase and rutile phases. The absorption edge of films calcined at $900^{\circ}C$ was red-shifted. This is due to the augmented absorption resulting from the phase transformation from anatase to rutile phase. And the transmittance of films decreased by the light scattering and absorption in the films. Photocatalytic activity of $Ag/TiO_2$ thin films was higher than that of the pure $TiO_2$ thin films.

A Study on Geoid Model Development Method in Philipphines (필리핀 지오이드모델의 개발방안 연구)

  • Lee, Suk-Bae;Pena, Bonifasio Dela
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.699-710
    • /
    • 2009
  • If a country has her geoid model, it could be determine accurate orthometric height because the geoid model could provide continuous equi-gravity potential surface. And it is possible to improve the coordinates accuracy of national control points through geodetic network adjustment considering geoidal heights. This study aims to find the best way to develop geoid model in Philippines which have similar topographic conditions as like Malaysia and Indonesia in Eastsouth asia. So, in this study, it is surveyed the general theories of geoid determination and development cases of geoid model in Asia and it is computed that the geoidal heights and gravity anomalies by spherical harmonic analysis using EGM2008, the latest earth geopotential model. The results show that first, the development of gravimetric geoid model based on airborne gravimetry is needed and second, about 200 GPS surveying data at national benchmark is needed. It is concluded that it is the most reasonable way to develop the hybrid geoid model through fitting geometric geoid by GPS/leveling data to gravimetric geoid. Also, it is proposed that four band spherical Fast fourier transformation(FFT) method for evaluation of Stokes integration and remove and restore technique using EGM2008 and SRTM for calculation of gravimetric geoid model and least square collocation algorithm for calculation of hybrid geoid model.

Bioequivalence of Alpit Tablet to Algiron Tablet (Cimetropium Bromide 50 mg) (알기론 정(브롬화 시메트로피움 50 mg)에 대한 알피트 정의 생물학적 동등성)

  • Cho, Hea-Young;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.1
    • /
    • pp.47-54
    • /
    • 2002
  • Cimetropium bromide, a quaternary ammonium compound which is chemically related to scopolamine, exhibits its antispasmodic activity by competing with acetylcholine for the muscarinic receptors of the smooth muscle of gastrointestinal tract. The drug has been used for the treatment of various disorders involving spasms of the musculature of the gastrointestinal, biliary and genitourinary tracts. The purpose of the present study was to evaluate the bioequivalence of two cimetropium bromide tablets, $Algiron^{TM}$ (Boehringer Ingelheim Korea Ltd.) and $Alpit^{TM}$ (Hana Pharmaceutical Co., Ltd.), according to the prior and revised guidelines of Korea Food and Drug Administration (KFDA). The cimetropium bromide release from the two cimetropium bromide tablets in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty normal male volunteers, $25.25{\pm}2.10$ years in age and $65.76{\pm}6.39$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After three tablets containing 50 mg of cimetropium bromide per tablet were orally administered, blood was taken at predetermined time intervals and the concentrations of cimetropium bromide in serum were determined using HPLC method with UV detector. The dissolution profiles of two cimetropium bromide tablets were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using non-transformed and logarithmically transformed $AUC_t\;and\;C_{max}$. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the $Algiron^{TM}$ were 2.19%, -5.97% and 3.49%, respectively. Minimum detectable differences $({\Delta})\;at \;{\alpha}=0.05\;and\;1-{\beta}=0.8$ were less than 20% (e.g., 13.71 %, 19.05% and 15.11% for $AUC_t,\;C_{max}\;and\;T_{max}$, respectively). The powers $(1-{\beta})\;at\;{\alpha}=0.05,\;{\Delta}=0.2\;for\;AUC_t$, $C_{max}\;and\;T_{max}$ were 97.79%, 83.22% and 95.60%, respectively. The 90% confidence intervals were within ${\pm}20%$ (e.g., $-5.84{\sim}10.21,\;-17.11{\sim}5.18\;and\;-5.35{\sim}12.33\;for\;AUC_t,\;C_{max}\;and\;T_{max}$, respectively). There were no sequence effect between two tablets in logarithmically transformed $AUC_t\;and\;C_{max}$. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) (e.g., $0.94{\sim}1.10\;and\;0.85{\sim}1.05\;for\;AUC_t\;and\;C_{max}$, respectively). Two parameters met the criteria of prior and revised KFDA guideline for bioequivalence, indicating that $Alpit^{TM}$ tablet is bioequivalent to $Algiron^{TM}$ tablet.