• 제목/요약/키워드: tracer gas method

검색결과 67건 처리시간 0.029초

공장에서 퍼지는 냄새에 관한 수치계산적 연구 (Numerical Simulation of the Odor Spreading in a Factory)

  • ;송은화;남현규;신춘식;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2540-2543
    • /
    • 2008
  • Liquid crystal displays (LCD's) are continuously coated with some chemicals in the clean room of a factory. Spreading of these chemicals is causing serious problems both in controlling clean room quality as well as to the workers inside the factory. It is required to alleviate or properly control the offensive odor which is mainly composed of propylene glycol mono ethyl acetate, novolak resin and photo active compound. The control strategy employed is to bleed the offensive odor gas out the clean room. A full scale 3D CFD model was created with anisotropic porous media, chemical species transport with no volumetric reaction, and thermal diffusion with propane gas (tracer gas) to simulate the odor spreading. A segregated implicit solver with standard k-$\varepsilon$ model is employed. The detailed CFD analysis made it possible to develop an effective method of ventilating the coater room and optimizing their capacities.

  • PDF

전산유체역학을 사용한 양돈장 내 작업환경 환기효율성 분석 (Analysis of Working Environment and Ventilation Efficiency in Pig House using Computational Fluid Dynamics)

  • 오병욱;이성원;김효철;서일환
    • 한국농공학회논문집
    • /
    • 제61권2호
    • /
    • pp.85-95
    • /
    • 2019
  • The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.

아 역청탄 촤 산화 반응속도론에 관한 실험적 연구 (A Experimental Study of Oxidation Kinetics for a Sub-Bituminous Coal Char)

  • 강기태;송주헌;이천성;장영준;전충환
    • 에너지공학
    • /
    • 제18권4호
    • /
    • pp.239-246
    • /
    • 2009
  • 본 논문에서는 주위 가스 온도와 체류시간에 따른 아 역청탄 촤 입자의 연소 특성에 관한 기본적인 연구를 진행하였다. 실험용 장비로써 노 내 온도 범위가 $900^{\circ}C$에서 $1400^{\circ}C$까지 조절이 가능한 DTF(drop tube furnace)를 설치하였고, 온도가 보정된 two color pyrometer를 DTF의상부에 장착하여 촤가 산화할 때의 입자 온도를 측정할 수 있게 하였다. 촤 산화 시 반응한 총 질량을 구하기 위해 열중량 분석기를 사용하였으며, 회분 추적법을 통해분석하였다. 이를 통해대기압 조건에서 촤가산화 할때질량 및 면적 반응성, 반응속도 상수들을 결정하였다.

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator

  • Han, Hwa-Taik;Kim, Min-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권2호
    • /
    • pp.83-88
    • /
    • 2005
  • This study investigates the air leakage and heat transfer characteristics of a commercially available rotary-type air-to-air heat exchanger with a fiber polyester matrix. Crossover leakage between the exhaust and supply air is measured using a tracer gas method for various ventilation rates and rotational speeds of the wheel. A correlation equation for the leakage is obtained by summing up pressure leakage and carryover leakage. The pressure leakage is observed to be a function of ventilation rate only, and the carryover leakage is found to be a linear function of wheel speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiency by taking into account the leakage ratio. The heat recovery efficiency decreases, as the ventilation rate increases. As the wheel speed increases, however, the efficiency increases initially but reaches a constant value for the speeds over 10rpm.

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

회전식 폐열회수 환기유닛의 공기누설 및 전열특성에 관한 실험적 연구 (An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator)

  • 한화택;김민규
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1197-1203
    • /
    • 2004
  • This study investigates the air leakage and heat transfer characteristics of a rotary-type air-to-air heat exchanger with a fiber polyester matrix. The leakage airflow rate is measured using a tracer gas method for various ventilation rates and rotational speeds of the matrix wheel. A correlation equation for air leakage is obtained by combining the pressure leakage and the carryover leakage. The pressure leakage is observed to be a function of ventilation airflow rate only, and the carryover leakage is found to be a linear function of rotational speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiencies by taking into account the air leakage ratio. As the ventilation rate increases, the heat recovery efficiency decreases. As the rotational speed of the matrix increases, the efficiency increases initially but reaches a constant value for the rotational speeds over 10 rpm.

환기실험을 일한 추적가스 방법의 응용 (Applications of tracer gas method for ventilation experiments)

  • 한화택
    • 대한설비공학회지:설비저널
    • /
    • 제28권6호
    • /
    • pp.452-462
    • /
    • 1999
  • 환기란 실내에 기류분포를 형성함으로써 발생된 오염물질을 제거하고 재실자에게 신선외기를 공급하기 위한 것이다. 실내의 오염농도는 오염 발생원의 특성과 실내의 환기상태에 의하여 결정되며 환기상태는 실내의 기류분포에 의하여 결정된다. 건축물에서 수행되고 있는 각종 오염물질에 대한 농도측정 실험은 환기의 결과로서 나타나는 실내오염의 정도를 파악하기 위한 것으로 환기의 성능 자체를 측정하기 위한 것이 아니다. 또한 실내의 기류속도 측정실험을 통하여 환기상태를 간접적으로 파악할 수 있으나 정량적인 환기 상태를 측정하지는 못한다. 단순히 기류속도가 크고 작음에 따라서 환기상태의 좋고 나쁨을 표현할 수 없기 때문이다. 그림 1은 이와 같은 환기실험에 관련된 3단계의 실험 종류와 이들 간의 상호 상관관계를 보이고 있다.

  • PDF

벌크의 산소농도가 폐기물(廢棄物)의 질산화(窒酸化) 및 탈질(脫窒)에 미치는 영향 -Tracer 로서의 15N 동위원소(同位元素) 및 FISH법(法)을 이용한 아산화질소발생원(亞酸化窒素發生源)의 규명(糾明)- (Effects of oxygen in the bulk of refuses on nitrification and denitrification -Study on sources of released nitrous oxide using 15N-isotope as a tracer and FISH method-)

  • 황선진;하나키 케이스케
    • 상하수도학회지
    • /
    • 제12권1호
    • /
    • pp.52-61
    • /
    • 1998
  • Nitrification and denitrification are important processes in the landfill site as they are deeply related with degradation and stabilization of refuse. Also nitrous oxide ($N_2O$) which is released from both nitrification and denitrification is known as greenhouse gas (GHG). The purpose of this study was to clarify the process by which $N_2O$ produced using $^{15}N$ isotope. Nitrate which was labeled to 10.08% with $^{15}KNO_3$ was used and $N_2O$ was analyzed with GC mass. Results was that even also when $O_2$ of bulk was 15%, $N_2O$ was released from denitrification. And as concentrations of $O_2$ increase, sum of $N_2O$ was released from denitrification. And as concentrations of $O_2$ increase, sum of $N_2O$ and $N_2$ was decreased and ratios of $N_2O$ in the reduced gases were increased. FISH technics also adaped to confirm whether which of nitrifiers existed in the substrates. When NEU was used of which the target was ammonia oxidizing bacteria, nitrifier was not detected at all. So it was confirmed that during the reaction denitrification was dominant process. Total bacteria distributions which were detected by EUB probe explained that as $O_2$ increase the number of bacteria also increase, but between the 10-15% of $O_2$ there was no any differences.

  • PDF

전주지역 강수의 황동위원소비와 대기오염원의 추적자로서 그 유용성 (Sulfur Isotopic Ratios in Precipitation around Chonju-city, Korea and Its Availability as a Tracer of the Source of Atmospheric Pollutants)

  • 나춘기;김선영;전서령;이무성;정재일
    • 자원환경지질
    • /
    • 제28권3호
    • /
    • pp.243-249
    • /
    • 1995
  • In order to investigate the origin of sulfate in rain waters and to evaluate the feasibility of using sulfur isotope method as a tracer of atmospheric pollutants, the sulfur isotopic ratio of sulfate in rain waters collected in Chonju city from October 1994 to March 1995 was monitored and was compared with those of possible sources proposed by previous works. The pH of rain waters shows an intermediate acidic range from 4.45 to 6.88 and their daily variation appears to be well correlated with to the amount of precipitation. The sulfur isotopic ratios of sulfate in rain waters show a highly restricted range from 0.0 to + 1.8‰. The ${\delta}^{34}S$ values are similar to those of soil and pine tree surrounding Chonju city, but largely deviate from those of China. D-parameter($d={\delta}D-8{\delta}^{18}O$) of rain waters varies from 9.4 to 28.8. The values indicate that the rain waters in Chonju city are originated from the rainy front of China continent. All data obtained from this study suggested that sulfate in the rain waters collected in Chonju city was mainly derived from the sulfur dioxide gas emitted by the petroleum combustion. Therefore, sulfur isotopic study for the precipitation provided an excellent tool for environmental assessment in this region and for tracing the source of atmospheric pollutants.

  • PDF