• 제목/요약/키워드: trace elements analysis

검색결과 274건 처리시간 0.029초

A proton induced X-ray emission (PIXE) analysis of concentration of major/trace and toxic elements in broiler gizzard and flesh of Tehsil Gujar Khan area in Pakistan

  • Nadeem, Khawar;Hussain, Javaid;Haq, Noaman Ul;Haq, A. Ul;Akram, Waheed;Ahmad, Ishaq
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.2042-2049
    • /
    • 2019
  • Ten gizzard and three flesh samples of the broiler were collected from different locations in Tehsil Gujar Khan District Rawalpindi, Pakistan. The samples were dried, crushed and ground. Pellets were prepared by pressing the powder of the samples and that of the Bovine liver 1577c reference material obtained from NIST, USA. Proton induced X-ray emission (PIXE) installed at National Center for Physics, Islamabad, Pakistan has been used as a reliable and improved technique to determine concentration of various major/trace and toxic elements e.g. S, Cl, K, Ca, Cl, Fe, Cu, Mn, Co, Zn, Ti, Cd, Ga, Cr, V and Ni, in the Gizzard and Flesh samples of the broiler. The concentrations of all the detected elements in the samples are statistically significant. The certified and measured values of the elements in the reference material were in agreement with each other within a deviation of 7%. S, Cl, K and Ca are within tolerable limits and are good for human consumption. Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn were more than the acceptable limits of World Health Organization, WHO whereas Ga, As, Sn, Sb and Pb are not detected in most of the samples.

암석 용해방법에 따른 미량원소 분석결과 비교

  • 최만식;정창식;박계헌
    • 암석학회지
    • /
    • 제3권1호
    • /
    • pp.41-48
    • /
    • 1994
  • 암석의 용해 방법에 따른 미량원소 분석결과를 비교해 보기 위해 미국 지질조사소의 암석 표준시료 3종류 (G-2, W-2, BHVO-1)를 비이커-가열판법, 마이크로파 오븐법, 알칼리 용융법으로 용해 시켜 유도결합 플라즈마 질량분석기를 사용, 각각의 미량원소 농도를 측정하여 용해 방법에 따른 차이를 살펴보았다. 전체적으로 보아 비이커-가열판법으로 용해시킨 경우와 마이크로파 오븐법으로 용해시킨 경우는 비슷한 분석결과를 보인다. 알칼리 용융법을 사용하여 용해시킨 경우 높은 온도 때문에 Pb, Cu, Rb 등의 휘발성 원소 상당 부분이 손실된다. 산분해법의 경우 Zr, Hf 등의 원소가 저어콘 등의 불용성 광물에 농집되어 있을 때에는 광물들의 불충분한 용해로 인해 측정 농동가 낮게 나타난다. 회토류 원소 분석결과는 시료 용해 방법 사이에 차이가 없었으며 추천치와 대체로 일치하였으나 알칼리 용융법의 경우 큰 희석인자로 인한 측정상의 문제점이 일부 있었다.

  • PDF

A New On-line Coprecipitation Preconcentration Technique for Trace Metal Analysis by ICP-AES

  • 박경희;박용남
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권5호
    • /
    • pp.422-427
    • /
    • 1995
  • In a stream of water sample, trace metal ions are quantitatively coprecipitated with Indium hydroxide and filtered. The filtered precipitate is continuously dissolved in 3 M nitric acid and introduced to ICP directly. The lead, cadmium, and copper are concentrated more than 10-fold and determined with ICP-AES at a sampling frequency of 10/hour. The detection limits are 2.89, 1.43,0.52 ppb for lead, cadmium, and copper respectively. Recoveries of lead, cadmium, and copper are 98.7, 94.3, and 104.5% respectively. The RSD values for three elements are about 3-5% currently.

산지별 녹용(鹿茸)류의 성분분석 연구(I) -미량금속의 정량 및 Gangliosides의 TLC Pattern 분석- (Studies on the Analysis of Constituents of Deer Horn(I) -Assay of Trace Elements and TLC Pattern Analysis of Gangliosides-)

  • 홍남두;원도희;김남재;장승엽;윤황금;김혜수
    • 생약학회지
    • /
    • 제22권3호
    • /
    • pp.171-182
    • /
    • 1991
  • Several experiments were carried for the purpose of establishing the basis for the quality evaluation of deer horn. Deer horn originated from China, New Zealand, Soviet and Alaska were used as objectives and some constituents involved in deer horn were assayed and compared with one another. Five kinds of trace elements including Ca and Fe were determined by atomic absorbance spectroscopy. The more the region came down from the top of the deer horn, the more the ratio of Ca to Fe content (Ca/Fe) was increased. The same increasing tendancy was observed in the case of ash content. Gangliosides were isolated from deer horn by alumina column chromatography and identified by TLC using gangliosides Type II obtained from bovine brain as the standard material. The TLC chromatograms were scanned by dual wavelength TLC scanner, then those TLC profiles were compared. Deer horn from China and New Zealand were analogous but those from Soviet and Alaska were each distinguished in their TLC profiles.

  • PDF

능가사 출토 종이와 섬유의 해부학적 성질 및 미량원소 분석 (Anatomical Characteristics and Trace Elements of Historical Papers and Cloths from Neunggasa Temple in Korea)

  • ;박원규
    • 보존과학회지
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2001
  • 본 연구의 목적은 전남 고흥 능가사 대웅전과 천왕문에서 발굴된 종이와 섬유의 해부학적 특성과 미량 화학성분을 광학현미경, 화상해석, 주사전자현미경(SEM-EDS)으로 분석하는 것이다. 모든 종이는 닥나무로 식별되었다. 인피섬유에서 분리된 투명막의 존재가 특징적이었다. 대웅전 벽에 붙여 있는 종이가 가장 손상이 심하였으며 천왕문에서 발굴된 책의 종이 세포는 비교적 보존 상태가 양호하였다. 천왕문의 동방지국상 아래에서 발굴된 섬유는 매우 좁은 세포폭을 갖는 실크이었다. SEM-EDS 분석에서 높은 실리카 함량이 발견되었다. 종이 내에서 발견된 칼슘, 철, 염소, 그 밖의 미량원소 분석 결과를 연대, 생산지 및 보존처리와 관련하여 고찰하였다.

  • PDF

중성자방사화분석에 의한 인체 6개 조직 내 기능성원소 함량 분포 조사 (Investigation of Dynamic Elemental Distribution in Six Human Tissues by Neutron Activation Analysis)

  • 강상훈;문종화;정용삼;조승연;이한영
    • 분석과학
    • /
    • 제15권4호
    • /
    • pp.365-372
    • /
    • 2002
  • 본 연구에서는 한국 성인의 인체 조직인 늑골, 폐, 간, 근육, 신장 및 갑상선에 함유된 무기원소들의 함량을 조사하였다. 이 조직들은 48시간 이내의 사망자들로부터 IAEA 권고방식에 따라 채취하여 동결건조 시킨 후 분말상태로 만들었다. 중성자 방사화분석법을 이들 시료에 적용하여 5개 다량원소인 Ca, Mg, Na, K, Cl과 12개 미량원소인 Mn, I, Sr, As, Br, Co, Cr, Cs, Fe, Rb, Se, Zn의 함량을 분석하였다. 측정결과의 정확도 확인용으로 3가지 표준물질을 이용하였으며, 대부분의 원소에서 10% 이내의 상대오차를 나타냈고, 분석값의 수용기준인 Z값은 2이내였다. 다량원소들은 인체조직에 일정량 이상 고르게 분포하고 있었으며, 미량원소들은 조직별, 연령별 특정 농도를 나타내었다. 특히, 갑상선에서 I은 1000 ${\mu}g/g$ 이상 집중적으로 분포하였으며, Ca과 Sr은 늑골에서 각각 15.9%와 84.4 ${\mu}g/g$으로 나타났다.

산업 도시의 산업단지 부지와 주거 지역의 대기 중 호흡성 분진과 구성 미량 원소의 특성 (Characteristics of Atmospheric Respirable Particulate Matters and Trace Elements within Industrial Complex and Residential Sites in an Industrial City)

  • 김모근;신승호;조완근
    • Environmental Analysis Health and Toxicology
    • /
    • 제25권1호
    • /
    • pp.27-40
    • /
    • 2010
  • The current study was designed to scientifically evaluate the atmospheric particulate pollution in residences relative to their proximity to a Korean major iron/metal industrial complex (IMIC). This objective was achieved by measuring the concentrations and elemental composition of particulate matter with aerodynamic diameters equal to or less than 10 ${\mu}m$(PM10) in industrial ambient air from IMIC and residential ambient air with relative proximities to IMIC. The trace metals were analyzed using an inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The industrial mean values exceeded the Korean year/70-${\mu}g/m^3$ standard for PM10, whereas the residential mean values did not. However, the maximum residential values did exceed or were close to the Korean PM10 year standard. For individual elements, the ambient concentrations ranged widely from values in the order of a few $ng/m^3$ to thousands of $ng/m^3$. The residential mean mass concentrations in the PM10 measured in the present study were higher than or similar to those reported in earlier studies. This study suggests that residents in neighborhoods near the IMIC are exposedto elevated particulate levels compared to residents living further away from such a source.

Studies on Solvent Extraction and Flotation Technique Using Metal-Dithizone Complexes(II). Determination of Trace Elements in Water Samples by Solvent Sublation

  • 김영상;최윤석;최희선
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권10호
    • /
    • pp.1036-1042
    • /
    • 1998
  • The preconcentration and determination of trace elements in water samples were studied by a solvent sublation utilizing dithizonate complexation. After metal dithizonates were formed, trace amounts of cadmium, cobalt, copper and lead were floated and extracted into small volume of a water-immiscible organic solvent on the surface of sample solution and determined in the solvent directly by GF-AAS. Several experimental conditions as formation condition of metal-dithizonate complexes, pH of solution, amount of dithizone, stirring time, the type and amount of surfactants, N2 bubbling rate and so on were optimized for the complete formation and effective flotation of the complexes. And also four kinds of light solvents were compared each other to extract the floated complexes, effectively. After the pH was adjusted to 4.0 with 5 M HNO3, 8.0 mL of 0.05% acetone solution of dithizone was added to 1.00 L water sample. The dithizonate complexes were flotated and extracted into the upper methyl isobutylketone (MIBK) layer by the addition of 2.0 mL 0.2% ethanolic sodium lauryl sulfate solution and with the aid of small nitrogen gas bubbles. And this solvent sublation method was applied to the analysis of real water samples and good results of more than 85% recoveries were obtained in spiked samples.

도.토기의 화학조성-경주 황남대총 출토 도.토기를 중심으로 (The scientific analysis of potteries excavated from Kyong-ju relics-In terms of potsherds excavated from Wangkyong, Walsung, Hwangnam great tomb)

  • 홍종욱;문환석;황진주;조남철
    • 보존과학연구
    • /
    • 통권20호
    • /
    • pp.91-120
    • /
    • 1999
  • This paper presents the results of investigation on crystal, firing temperature and trace elements analysis of fragments 4~8 centriesexcavated from Kyong ju historical sites such as Wang kyong,Walsung, Hwangnam great tomb by application of optical microscope, neutron activation analysis and X-ray diffraction. Temper analysis of clay for identification of local or foreign production; Trace elements is not presented a unique chemical composition. That’s data have to be treated a statistical process in order to normalize. The results followed ;(1) Firing temperature could be estimated $700^{\circ}C$ on some softness pottery at Walsung and most of hardness others are $1,000^{\circ}C$ to $1,200^{\circ}C$.(2) Crystal structures are divided into three kinds of mineralogical composition(Quartz, Mullite, Feldspar).(3) Considering of the results of statistical data, chemical composition of Walsung is more similarly Wang kyong than Hwangnam great tomb.

  • PDF

중성자방사화분석법에 의한 전자소재용 고분자수지의 불순물 분석법연구 (Trace impurities analysis of the electronic polymer resins by neutron activation analysis)

  • 윤윤열;조수영;이길용;양명권;심상권;정용삼
    • 분석과학
    • /
    • 제17권4호
    • /
    • pp.308-314
    • /
    • 2004
  • 전자소재의 원료물질 혹은 보호물질에 사용되는 고분자수지내에 포함된 U, Th과 이들의 붕괴산물인 딸핵종과 같은 방사성 불순물이 있는 경우 전자소자의 오작동을 일으키는 주 요인으로 알려져 있으며, Na, Cl, Fe 등과 같은 이온성 불순물은 소자의 수명을 단축시키는 것으로 알려져 있어 극미량 무기불순물의 정확한 분석이 필요하다. NAA의 경우, 위와 같은 분석의 문제점인 시료전처리가 필요하지 않은 비파괴 분석이 가능하여 가장 적합한 분석법으로서 고분자수지중의 극미량 불순물 분석을 위한 시료 전처리법과 최적 분석방법을 개발하였다. 이 방법을 사용하여 전자소재의 밀봉보호재로 널리 이용되고 있는 에폭시수지와 페놀수지중의 극미량 무기 불순물을 분석기술을 개발하였으며, 그 결과 U, Th과 이온성 불순물인 Cl, Fe, Na 외에 20가지의 미량 무기불순물을 분석할 수 있었다.