• Title/Summary/Keyword: trace analysis

Search Result 1,352, Processing Time 0.021 seconds

Power Trace Selection Method in Template Profiling Phase for Improvements of Template Attack (프로파일링 단계에서 파형 선별을 통한 템플릿 공격의 성능 향상)

  • Jin, Sunghyun;Kim, Taewon;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • Template attack is a powerful side-channel analysis technique which can be performed by an attacker who has a test device that is identical to target device. Template attack is consisted of building template in profiling phase and matching the target device using template that were calculated in profiling phase. One methods to improve the success rate of template attack is to better estimate template which is consisted sample mean and sample covariance matrix of gaussian distribution in template profiling. However restriction of power trace in profiling phase led to poor template estimation. In this paper, we propose new method to select noisy power trace in profiling phase. By eliminating noisy power trace in profiling phase, we can construct more advanced mean and covariance matrix which relates to better performance in template attack. We proved that the proposed method is valid through experiments.

A Study on the Characteristics of Heat Treated ERW Weld Seam and the Technology of Seam Annealing (고장력 강재의 전기저항 용접부 열처리 특성 및 기술에 대한 연구)

    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.133-144
    • /
    • 1999
  • To fine seam annealer capacity of through thickness seam annealing in terms of through thickness microstructure change with increased toughness and elongation leaving heat trace on it, high strength steel pipes of ERW with different thickness were tested in different seam annealing temperature measured on the outer surface of pipes. Annealing temperature and microstructure of the weld seam were changed through applied seam annealing condition. Toughness and tensile test with hardness and microstructure analysis were done on the annealed weld seam to fine its characteristics as a primary step and annealing characteristics according to different seam annealing condition. Through a study of annealed ERW weld seam characteristics and seam annealing technology, amount of electric power should apply in decreased manner to arranged inductors of annealer in the order of 1st, 2nd, 3rd, so on for proper seam annealing. For example of 15.4mm thick and 610mm outside diameter pipe, applied power for proper seam annealing is 600 -650kw at 1st inductor, 450 - 500kw at 2nd inductor, 200-250 kw at 3rd inductor of annealer during 10 - 12M/minute moving speed of pipe. Also, the penetration depth of heat trace along the thickness direction of weld during seam annealing can be estimated through the equation 17mm/kv$\times$voltage(kv) with the microstructure and hardness analysis of thick weld seam as well as study of seam annealing and comparison of cooling condition to CCT diagram of low carbon high strength steel. From this result, the difference between the technological applicability of full annealing condition based on phase diagram and full penetration of heat trace based on CCT diagram along the thickness of weld seam is discussed.

  • PDF

Trace Elements and Source Assessment of Street Dust in Daegu, Korea (대구지역 도로먼지에 함유된 미량원소성분과 오염원 평가)

  • Song, Hee-Bong;Lee, Eun-Young;Do, Hwa-Seok;Jung, Cheol-Su;Shin, Dong-Chan;Lee, Myoung-Sook;Paek, Yoon-Kyoung;Jeon, Seong-Suk;Shin, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.793-800
    • /
    • 2007
  • A total of 48 samples of street dust were collected in Daegu area during April and May 2006, were sieved below 100 ${\mu}m$, and analysed by ICP for the analysis of 14 elements after an acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources such as soil and dust, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by urban anthropogenic sources such as fuel combustion and waste incineration. The measured values were remarkably higher in components from natural sources than in components from urban anthropogenic sources. The concentrations of trace elements in Daegu area were generally higher than in other foreign cities. Samples originated from industrial and commercial areas had higher concentrations of trace elements and pollution indices of heavy metals than those from residential and green areas. The correlation analysis among trace elements indicated that the correlations among components from urban anthropogenic sources were much significant, while those among components from natural sources were less correlated. In addition there were significant correlations between traffic density and components from urban anthropogenic sources.

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

Analysis and parameter extraction of motion blurred image (움직임 열화 현상이 발생한 영상의 분석과 파라메터 추출)

  • 최지웅;최병철;강문기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10B
    • /
    • pp.1953-1962
    • /
    • 1999
  • While acquiring the image, the shaking of the image capturing equipment or the object seriously damages the image quality. This phenomenon, which degrades the clarity and the resolution of the image is called motion blur. In this paper, a newly defined function is introduced for finding the degree and the length of the motion blur. The domain of this function defined as Peak-trace domain. In The Peak-trace domain, the noise dominant region for calculating the noise variance and the signal dominant region for extracting the degree and the length of the motion blur are defined and analyzed. Using the information of the Peak-trace in the signal dominant region, we can find the direction of the motion regardless of the noise corruption. Weighted least mean square method helps extracting the Peak-trace more precisely. After getting the direction of the motion blur, we can find the length of the motion blur based on one dimensional Cepstrum. In the experiment, we could efficiently restore the degraded image using the information obtained by the proposed algorithm.

  • PDF

Distribution and Contamination Status of Trace Metals in Surface Sediments of Shellfish Farming Areas in Yeoja and Gangjin Bays, Korea (남해안 패류양식해역(여자만과 강진만)의 퇴적물내 미량금속 분포특성 및 오염도 평가)

  • Choi, Minkyu;Lee, In-Seok;Kim, Hyung-Chul;Hwang, Dong-Woon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.5
    • /
    • pp.789-797
    • /
    • 2015
  • The concentrations of trace metals (As, Cd, Cr, Cu, Fe, Hg, Mn, Pb, and Zn) were determined in 49 surface sediment samples collected in Yeoja and Gangjin Bays on the south coast of Korea, which contain many shellfish farms, in order to assess the contamination level and to understand the spatial distribution of trace metals. The average metal concentrations in the surface sediments of both bays decreased in the order Fe > Mn > Zn > Cr > Pb > Cu > As > Cd > Hg. There were no differences in metal concentrations between shellfish farms and reference sites. The metal concentrations were significantly higher in Gangjin Bay than in Yeoja Bay. Notably, the Cu, Cd, and Hg concentrations were nearly twice as high in Gangjin Bay as in Yeoja Bay. A multivariate analysis showed a strong correlation among Fe, Mn, Zn, Pb, and Cr in the sediments of both bays, implying that the metal concentrations in the sediments in the study area were mainly dependent on natural processes, such as crustal components and diagenesis. Based on the geoaccumulation index and marine sediment quality guidelines (SQGs), the surface sediments in Yeoja and Gangjin Bays are not polluted by trace metals.

The Contents of Heavy Metal in Fruits and Vegetables Collected from Jinju District (진주지방(晋州地方)의 원예작물중(園藝作物中) 중금속함량(重金屬含量))

  • Kim, Myung-Chan;Sung, Nack-Kie;Shim, Ki-Hwan;Lee, Min-Hyo;Lee, Jae-In
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.299-306
    • /
    • 1981
  • Contents of heavy metals in fruits and vegetables collected from Jinju district of Korea during June 1980 to March 1981 were determined. Statistical analysis of the data showed the maximum, minimum, mean and standard deviation for each variable. The ranges of their amounts in fruits and vegetables were lead, $trace{\sim}0.829\;ppm\;;mercury,\:ND{\sim}0.368\;ppm;cadmium,\;ND{\sim}0.264\;ppm;\;arsenic,\;trace{\sim}1.289\;ppm;\;copper,0.200{\sim}3.759\;ppm;\;zinc,\;0.327{\sim}21.663\;ppm;\; manganese,\;0.828{\sim}22.413\;ppm;\;iron,\;0.201{\sim}32.425 ppm,$ respectively and the content of chromium was in trace for 4 samples.

  • PDF

A Study on Dynamic Code Analysis Method using 2nd Generation PT(Processor Trace) (2세대 PT(Processor Trace)를 이용한 동적 코드분석 방법 연구)

  • Kim, Hyuncheol
    • Convergence Security Journal
    • /
    • v.19 no.1
    • /
    • pp.97-101
    • /
    • 2019
  • If the operating system's core file contains an Intel PT, the debugger can not only check the program state at the time of the crash, but can also reconfigure the control flow that caused the crash. We can also extend the execution trace scope to the entire system to debug kernel panics and other system hangs. The second-generation PT, the WinIPT library, includes an Intel PT driver with additional code to run process and core-specific traces through the IOCTL and registry mechanisms provided by Windows 10 (RS5). In other words, the PT trace information, which was limited access only by the first generation PT, can be executed by process and core by the IOCTL and registry mechanism provided by the operating system in the second generation PT. In this paper, we compare and describe methods for collecting, storing, decoding and detecting malicious codes of data packets in a window environment using 1/2 generation PT.

Single Trace Side Channel Analysis on NTRUEncrypt Implementation (NTRUEncrypt에 대한 단일 파형 기반 전력 분석)

  • An, Soojung;Kim, Suhri;Jin, Sunghyun;Kim, HanBit;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.5
    • /
    • pp.1089-1098
    • /
    • 2018
  • As the development of quantum computers becomes visible, the researches on post-quantum cryptography to alternate the present cryptography system have actively pursued. To substitute RSA and Elliptic Curve Cryptosystem, post-quantum cryptography must also consider side channel resistance in implementation. In this paper, we propose a side channel analysis on NTRU, based on the implementation made public in the NIST standardization. Unlike the previous analysis which exploits a thousands of traces, the proposed attack can recover the private key using a single power consumption trace. Our attack not only reduces the complexity of the attack but also gives more possibility to analyze a practical public key cryptosystem. Furthermore, we suggested the countermeasure against our attacks. Our countermeasure is much more efficient than existing implementation.