• 제목/요약/키워드: tower column

검색결과 64건 처리시간 0.027초

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

초고층 구조물 건전성 모니터링을 위한 축응력 계측 및 해석에 관한 연구 (A Study on Axial Stress Measurement and analysis of High-rise Building Structure Health Monitoring)

  • 이종호;김선규;전영준;이승민;임종순
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2015
  • This study was performed for application of Structural Health Monitoring system of Jamsil Lotte World Tower. Axial stresses of mega column and core wall are measured in the past 29 months for axial stress monitoring and evaluating predicted self weight. We use the midas gen program(FEM analysis program) with construction stage analysis mode to predict axial stress. 8 mega column axial stressmeters are installed at 21st floor and 4 core wall stressmeters are installed at 38th floor. Measurement data was obtained without creep and shrinkage effect.

  • PDF

무다짐 콘크리트를 이용한 높은 40m CFT 기둥의 시공 (Practical Use of Self Compacting Concrete to be filled inside the Steel Tube Columns)

  • 김규동;김한준;손유신;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1023-1028
    • /
    • 2003
  • The structure of Tower Palace III Sports Center building was designed as concrete Filled Steel Tube(CFT) Column and the filled-in concrete was designed as high compressive strength of 500kgf/$m_2$. The self compacting concrete(SCC, non-vibrating concrete) with 65$\pm$5cm flow must be applied to this case for filling the CFT by injecting the concrete from the column bottom. Laboratory tests and pilot productions of batcher plant were performed for optimum mix design and the full scale Mock-Up test was performed to check the appicability of the construction method. As a result, we observed that good quality SCC and the pressure change of concrete pump normally used domestically. Based on these results, we have constructed 20-40m height CFT columns successfully.

  • PDF

Structural System Selection and Highlights of Changsha IFC T1 Tower

  • Jianlong, Zhou;Daoyuan, Lu;Liang, Huang;Jun, Ji;Jun, Zhu;Jingyu, Wang
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.99-106
    • /
    • 2014
  • This paper presents the determination of the structural system of the Changsha IFC T1 tower with 452 m in architectural height and 440.45 m in structural height. Sensitivity analyses are carried out by varying the location of belt trusses and outriggers. The enhancement of seismic capacity of the outer frame by reasonably adjusting the column size is confirmed based on parametric studies. The results from construction simulation including the non-load effect of structures demonstrate that the deformation of vertical members has little effect on the load-bearing capacity of belt trusses and outriggers. The elastoplastic time-history analysis shows that the overall structure under rare earthquake load remains in an elastic state. The influence of the frame shear ratio and frame overturning moment ratio on the proposed model and equivalent mega column model is investigated. It is found that the frame overturning moment ratio is more applicable for judging the resistance of the outer frame against lateral loads. Comparison is made on the variation of these two effects between a classical frame-core tube-outrigger structure and a structure with diagonal braces between super columns under rare earthquakes. The results indicate that plasticity development of the top core cube of the braced structure may be significantly improved.

Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance

  • Kumano, Takehito;Yoshida, Satoshi;Saburi, Kazuhiro
    • 국제초고층학회논문집
    • /
    • 제6권3호
    • /
    • pp.217-226
    • /
    • 2017
  • This paper summarizes the structural concept and design of the "Nakanoshima Festival Tower West" in Osaka, Japan, which is 200m high and has a super-high damping system. Its superstructure is mainly composed of a central core and outer tube frames. It has a bottom truss structure at the boundary between the low-rise and mid-rise sections of the building, where the column arrangement is changed. Besides, the high-rise section of the building has a neck truss structure. These truss structures smoothly transfer the axial forces of the columns and reduce the flexural deformations induced by horizontal loads. Oil dampers with extremely high damping capacity are installed in the rigid walls named the "Big Wall Frames" of the low-rise section. Moreover, many braces and damping devices are well arranged in the center core of each story. The damping effects of these devices ensure that all structural members are remain within the elastic range and that story drifts are within 1/150 in large earthquakes. This super-high damping structure in the low-rise section is named the "Damping Layer". The whole structural system is named the "Super Damping Structure". The whole structural systems enhance the building's safety, comfort and Business Continuity Planning (BCP) under large earthquakes.

잠실제2롯데월드용 고강도 콘크리트 크리프 및 건조수축 실험결과 및 예측결과 비교분석 (Creep and Shrinkage Strain and Comparative Analysis Between Concrete Test and Experimental Results of Lotte Super Tower)

  • 차한일;문형재;석원균;박순잔;이주호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.309-310
    • /
    • 2009
  • 본 연구는 잠실제2롯데월드 초고층 건축 프로젝트의 기둥축소량에 필요한 첫 번째 단계인 재료연구(일명 콘크리트 테스트 프로그램)의 일환으로 진행되고 있다. 현재까지 18개월간의 크리프 및 건조수축 측정결과가 확보되어 있으며 이에 대한 강도와 하중재령별로 분석을 실시하였고 추가적으로 회기분석을 실시하여 예측모델식에 따른 유도식을 제안하였다. 비교분석 시 사용된 예측 모델식은 ACI209R Model, Bazant-Baweja B3 Model, CEB MC99 Model, 및 GL2000 Model 등과 같이 네 가지 의 모델식을 활용하였다. 결과분석항목은 실무에서 활용되고 있는 전체 건조수축 변형과 단위 응력당 전체 크리프 변형(Compliance)에 대해서 실시하였다.

  • PDF

Study on wind-induced vibration response of Jiayuguan wooden building

  • Teng Y. Xue;Hong B. Liu;Ting Zhou;Xin C. Chen;Xiang Zhang;Zhi P. Zou
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.245-254
    • /
    • 2023
  • In this paper, the wind-induced response of Jiayuguan wooden building (world cultural heritage) in Northwest China was studied. ANSYS finite element software was used to establish four kinds of building models under different working conditions and carry out modal analysis. The simulation results were compared with the field dynamic test results, obtaining the model which reflects the real vibration characteristics of the wooden tower. Time history data of fluctuating wind speed was obtained by MATLAB programming. Time domain method and ANSYS were used to analyze the wind-induced vibration response time history of Jiayuguan wooden building, obtaining the displacement time history curve of the structure. It was suggested that the wind-induced vibration coefficient of Jiayuguan wooden building is 1.76. Through analysis of the performance of the building under equivalent static wind load, the maximum displacement occurs in the three-story wall, gold column and the whole roof area, and the maximum displacement of the building is 5.39 cm. The ratio of the maximum stress value to the allowable value of wood tensile strength is 45 %. The research results can provide reference for the wind resistant design and protection of ancient buildings with similar structure to Jiayuguan wooden tower.

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구 (A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower)

  • 강성진;임동하
    • 청정기술
    • /
    • 제26권2호
    • /
    • pp.102-108
    • /
    • 2020
  • 오늘날 석유화학, 정밀화학, 대기오염 방지산업 등에서 증류, 흡수, 추출, 탈거 등 물질분리 단위공정으로 주로 충전탑을 사용해 왔다. 충전탑은 가스-액체, 가스-가스 시스템에서의 물질들과의 접촉에 의해 운전되어 진다. 이러한 충전탑은 낮은 압력손실, 경제적 효율, 고온성 액체물질 적용, 유지보수 용이, 유해가스 처리 등의 운영에서 장점들을 가진다. 충전탑의 성능은 충진물을 통해 가스와 액체를 고르게 분산함으로써 우수한 성능을 보이며, 이는 충전탑 설계에 있어 중요한 인자로 고려되어진다. 본 실험에서는 충진물에 대한 액체부하 및 가스용량인자에 따른 건조압력손실, 수력학적 압력손실, 액체함량 변화에 대한 기하학적 특성에 대하여 연구하였다. 결과로부터 설계인자와 운전조건 등의 유해가스 처리에 필요한 인자를 도출하였다. 임의 충진물인 raschig super-ring에 대한 건조압력손실을 측정한 결과, 가스용량인자가 증가할수록 일정하게 선형적으로 증가하였고, 가스용량인자가 0.630 ~ 3.448 kg-1/2 m-1/2 S-1에서 건조압력손실은 1.892 ~ 47.312 mmH2O m-1로 기존 산업현장에서 보편적으로 사용되는 35 mm pall-ring보다도 낮은 압력손실을 보였다. 그리고 raschig super-ring에 대한 수력학적 압력손실을 측정한 결과, 고유 액체부하에 대하여 가스용량인자가 증가할수록 압력손실도 함께 증가함을 확인하였고, 액체부하 변화에 따른 가스용량인자가 1.855 ~ 2.323 kg-1/2 m-1/2 S-1으로 20% 증가할 때, 압력손실은 약 17% 증가하는 것으로 나타났다. 마지막으로, 충진물 체적에 관한 액체함량은 가스용량인자에 의존된 액체부하 매개변수로서 액체부하 변화에 따른 가스용량인자 약 3.84 kg-1/2 m-1/2 S-1까지는 거의 일정한 액체함량을 보였으나, 그 이상에서는 급격하게 증가하였다.

고효율 역류흐름 충전탑에서 물질전달에 관한 연구 (High Performance Count-current Flow in Packed Tower Design)

  • 강성진;박치균;길성재;이경학;이만식
    • 응용화학
    • /
    • 제17권1호
    • /
    • pp.21-24
    • /
    • 2013
  • High performance count-current flow in packedtower design. Column that packed with Montz packing regular and dumped packing with Pall Ring, Hiflow Ring and Hackette have been represented high performance in vaccum rectification and absorption. The new correlating of these relationship based on the numerous results has been developed for process calculation and design. The results of laboratory or experimental pilot plant can be adopted directly for scale-up.