• Title/Summary/Keyword: total water

Search Result 12,328, Processing Time 0.032 seconds

Current Status of Drinking Water Treatment and its Countermeasure (국내외 정수처리 기술의 현황)

  • 류재근
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.67-92
    • /
    • 1997
  • Tap water should be shown the complexity of measures neccessary to secure water quality, especially with respect to drinking and bathing. Designated reservoirs Paldang and Daechung as the Special Environment Protection Areas to regulate new pollution sources and to facilitate construction of wastewater treatment facilities. In this country, 91% of total drinking water resource, consist of 66% stream water, 25% dam water, 7% dune flitrate, 1% each of spring and ground water, are from the surface water. The total volume of annual mean water resources due to precipitation. Over 8% of the total resources are class III as shown in the table., eapecially the water quality of downstream of Nakdong and Yeongsan river are getting worse due to continued economic and social development.

  • PDF

Market Evaluation of Seawater Desalination Plant considering International Water Scarcity and Expense Outlook by Use and Nation (해외 물 기근 현황과 용도별.국가별 자본지출 전망을 고려한 해수담수화 플랜트 시장성 평가)

  • Yang, Jeong-Seok;Sohn, Jinsik;Kang, Dae-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.178-187
    • /
    • 2011
  • National water supply, water resources available, the ratio of water supply to total water resources, and the ratio of water supply to available water resources were investigated to find global seawater desalination plant market for 163 nations. Water resources available per capita from 2007 to 2016, population in water scarcity region from 2011 to 2016, and the ratio of water scarcity population to total population were also analyzed for the countries. Annual percentage increase in total municipal drinking water capital expenditure and Annual percentage increase in total industrial water market were analyzed to predict the amount of water supply by use. 76 countries are suffering from water scarcity and 60 countries among the countries have coastal regions. Forty countries were selected by considering the considerable amount and highly increasing trend of water demand by use. Most countries show increasing trend of industrial water and 82 countries have more than 4% annual increasing rate for domestic water expense from 2008 to 2016 among 163 countries. Among the 76 water scarcity countries 16 countries were finally selected by considering expense prediction by use. Middle-east, east asia, pacific ocean, and west europe regions include most selected countries.

Coliform Regrowth and Injured Coliforms in Public Water Supply (수돗물에서의 대장균군 재생장과 손상 대장균군)

  • 박성주;조재창;김상종
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.50-57
    • /
    • 1994
  • Densities of total and injured coliforms in treated water( TW ) and three tap water salt pies( Taps Kl, K2 and K3) of Ku- eui water treatment plant and one tap water sample( Tap T) of Tuk- do water treatment plant were measured 23 times from 1991 to 1992. Coliform regrowth in the water distribution system occurred three times during the study period. When the regrowth episode occurred, injured coliforms were always but total coliforms were not always detected in treated water. Mean densities of total coliforms in TW, and Taps Kl, K2, K3 and T were 0.8, 2.3, 1.9, 1.4 and 2.1 cfu/100mℓ by membrane filtration method using m- TF agar and those of injured coliforms were 3.4, 2.8, 2.5, 2.7 and 2.9 c1u/100mℓ using mondo- LES agar. The injury rates of TW and Taps Kl, K2, K3 and T were 89.5,77.4,67.9, 82.8 and 75.9%, respectively. The high injury rate of coliform bacteria in Seoul water supply can cause regrowth problems in distribution systems due to the repair of injured cells under an appropriate condition. It is recommended the injured coliforms should be measured in drinking water since they can lead to a significant underestimation of total coliforms and result in an inaccurate evaluation of the potential health risks.

  • PDF

A Study on the Implementation Method of Total Water Quality Load Management in Sapkyo Lake Watershed (삽교호수계의 수질총량관리제 시행방안 연구)

  • Yi, Sang-jin;Oh, Hye-jeong;Lee, Eun-hyoung;Jung, Jong-Gwan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.807-814
    • /
    • 2006
  • Sapkyo Lake Watershed occupies about 19.3% of total area of Chungnam Province, and it is necessary to make a plan of counter-measure for the maintenance of public waterbody sound as well as to ensure water resources due to urbanization and industrialization in this area so densely populated and excessively developed. Conventionally water quality management has been enforced by concentration-based system which is not considered the carrying capacity of receptors, hence there are no proper measures for the prevention of an excessive pollutant load over a waterbody. So even though emission sources abide by the conventional permission regulation, then the quantity of wastewater is increased continuously and encountered water shortage to use finally. Therefore this research focused on the review of introduction of total water quality management system in Sapkyo Lake watershed to maintain public waterbody sound and to ensure water resources. By doing this research in introduction of the system in advance, it can contribute to establish the methodology on systematic water quality management. Also the application of this system in Sapkyo Lake watershed can promote the sustainable development of the area by harmonizing the environment and regional economy ultimately.

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

Quality Assessment of the Nationwide Water Pollution Source Survey Results on the Prioritized Toxic Water Pollutants from Industrial Sources in the Geum-River Basin by Exploratory Data Analysis (금강유역 산업계 특정수질유해물질 배출현황에 대한 탐색적 데이터 분석을 통한 전국오염원조사 결과 적합성 평가)

  • Kim, Eun-Ah;Kim, Yeon-Suk;Kim, Yong Seok;Rhew, Doug Hee;Jung, Je Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.585-595
    • /
    • 2014
  • The temporal trends of the prioritized toxic water pollutants generated and discharged from the industrial facilities in the Geum-River basin, Korea were analyzed with the results of the nationwide Water Pollution Source Survey conducted in 2001 - 2012. The statistical results indicated rapid increase in the volume of raw toxic wastewaters whereas the amount of each toxic pollutant kept fluctuating for 12 years. Serious discrepancies in the survey data of the same type of industries demonstrated a low reliability of the survey result, which stemmed from several error factors. A unit-load for each type of industrial facility was devised to estimate the amount of prioritized toxic water pollutant based on the total volume of industrial wastewater generated from the same type of industrial facilities. The supplementary measures with an effective permit issuance policy and adding survey parameters of terminal wastewater treatment plants to use them as references to the Water Pollution Source Survey were suggested as means to minimize the errors associated with the false reports from the industries.

Water Quality Monitoring and Risk Assessment for Groundwater at Hoengseong, Gangwon-do Province (강원도 횡성지역의 지하수 수질 모니터링 및 인체 위해성 평가)

  • Gang, Seung-Hye;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.356-365
    • /
    • 2021
  • Background: Concerns have been raised regarding the criteria of groundwater, in particular in Gwangwon-do Province where many residents drink groundwater due to the poor supply of tap water and a high nonconformity rate with water quality criteria nationwide. Objectives: Water quality monitoring and risk assessment were conducted for groundwater in Hoengseong, Gangwon-do Province. Methods: A total of 46 items required for meeting drinking water criteria were analyzed from 258 samples collected from March 2017 through August 2018 (152 sites in 2017 and 106 sites in 2018). Risk assessment was conducted for two non-carcinogens (F- and NO3-N), and one carcinogen (i.e., arsenic) based on their high nonconformity to water quality criteria. Results: Water quality analysis revealed that the total proportion of nonconformities was determined to be 27.9%. The nonconformity rate for each content item is as follows: total colony counts (1.6%), total coliform (6.2%), Escherichia coli (1.2%), F- (8.1%), arsenic (4.7%), NO3-N (8.1%), pH (1.2%), manganese (0.4%), and turbidity (5.8%). Risk assessment indicated that fluoride induced a hazard quotient greater than 1 with the 95% UCL (Upper Confidence Limit) concentration of the total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. For NO3-N, there was no human health risk. For arsenic, the excess cancer risk exceeded the acceptable cancer risk of 1×10-6 with the average and 95% UCL concentrations of total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. Conclusions: This study suggests that it is necessary to expand water quality monitoring of groundwater and conduct a more detailed risk assessment in order to establish a health care plan for the residents of Hoengseong, Gangwon-do Province.

ARIMA 모형에 의한 하천수질 예측

  • 류병로;한양수
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.433-440
    • /
    • 1998
  • This study was carried out to develop the stream water quality model for the intaking station of Kongju waterworks in the Keum River system. The monthly water quality(total nitrogen and total phosphorus) with periodicity and trend were forecasted by multiplicative ARIU models and then the applicability of the models was tested based on 7 years of the historical monthly water quality data at Kongju intaking strate. The parameter estimation was made with the monthly observed data. The last one year data was used to compare the forecasted water Quality by ARU model with the observed one. The models are ARIMA(2,0,0)$\times$(0,1,1)l2 for total nitrogen, ARIMA(0,1,1)x(0,1,1)l2 for total phosphorus. The forecasting results showed a good agreement with the observed data. It is implying the applicability of multiplicative ARIMA model for forecasting monthly water quality at the Kongju site.

  • PDF

Inactivation Rate of Enterococci and Total Coliforms in Fresh Water and Sea Water (해수 및 담수에서 장구균과 총대장균군의 불활성화)

  • Kim, Jongmin;Jheong, Weonhwa;Choi, Heejin
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.136-141
    • /
    • 2009
  • Inactivation rates between enterococci and total coliforms were compared in order to find the suitability of enterococci as an indicator microorganism under various experiment conditions - freshwater and/or seawater, indoor and/or outdoor conditions. In case of indoor laboratory experiments, inactivation rates of enterococci ($k_D$: 0.050~0.082) were faster than those of total coliforms ($k_D$: 0.034~0.045) in freshwater matrix. In seawater matrix, however, survival rate of enterococci was longer than that of total coliforms at two out of three experiments in indoor condition. When incubated in outdoor conditions, enterococci were inactivated significantly more rapidly than total coliforms both in freshwater and seawater matrices. With these results, enterococci appear to be less suitable than total coliforms in terms of inactivation rates.

Assessment of Water Quality using Multivariate Statistical Techniques: A Case Study of the Nakdong River Basin, Korea

  • Park, Seongmook;Kazama, Futaba;Lee, Shunhwa
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.197-203
    • /
    • 2014
  • This study estimated spatial and seasonal variation of water quality to understand characteristics of Nakdong river basin, Korea. All together 11 parameters (discharge, water temperature, dissolved oxygen, 5-day biochemical oxygen demand, chemical oxygen demand, pH, suspended solids, electrical conductivity, total nitrogen, total phosphorus, and total organic carbon) at 22 different sites for the period of 2003-2011 were analyzed using multivariate statistical techniques (cluster analysis, principal component analysis and factor analysis). Hierarchical cluster analysis grouped whole river basin into three zones, i.e., relatively less polluted (LP), medium polluted (MP) and highly polluted (HP) based on similarity of water quality characteristics. The results of factor analysis/principal component analysis explained up to 83.0%, 81.7% and 82.7% of total variance in water quality data of LP, MP, and HP zones, respectively. The rotated components of PCA obtained from factor analysis indicate that the parameters responsible for water quality variations were mainly related to discharge and total pollution loads (non-point pollution source) in LP, MP and HP areas; organic and nutrient pollution in LP and HP zones; and temperature, DO and TN in LP zone. This study demonstrates the usefulness of multivariate statistical techniques for analysis and interpretation of multi-parameter, multi-location and multi-year data sets.