Effect of Pressure Taping between Tibia and Fibula on Pain, ROM and Strength in Athletes diagnosed with High Ankle Sprain (원위경비인대결합 손상 선수의 경·비간 압박테이핑 적용이 통증, 관절가동범위, 근력에 미치는 영향)

  • Jang, Won-Bong;Oh, Jae-Keun;Yoon, Jin-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.303-310
    • /
    • 2021
  • This study was conducted to identify the effects of pressure taping between tibia and fibula of High Ankle Sprain athletes on pain, Range of Motion(ROM), and strength and to provide basic data for rehabilitation programs. The subjects of the study were conducted with a total of 10 athletes except for four who gave up who were diagnosed with high ankle sprain, or who were diagnosed with ankle sprain but their physical examinations proved positive. The results showed no significant differences in pain(Visual Analog Scale, VAS). The ROM was significantly increased in inversion(IV) and eversion(EV) in both groups. The Isometric strength was significantly improved in IV(0°, 7°, 14°) and EV(0°) in Taping Group(TG). When taping was applied to athletes with injury to the High Ankle Sprain, ROM and muscle strength improved at the same pain level.

The Outcome of Anterior Cruciate Ligament Reconstruction in Patients with Meniscal Injury (반월판 연골 손상이 동반된 환자에서 전방 십자 인대 재건술의 임상적 결과)

  • Lee Kwang Won;Park Jae Guk;Jung Yu Hun;Kim Byung Sung;Kim Ha Yong;Choy Won Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Purpose : To analyze the anterior stability and functional results after the arthroscopic ACL reconstruction and meniscectomy based on meniscus status at the time of surgery. Materials and Methods : From October 1997 to October 2002, 78 patients (male 64 female 14) were treated by arthroscopic ACL reconstruction and meniscectomy and followed more than 12 months (range, $12\~72$ months, average: 32 months). Average age was 32 years old (range, $18\~57$ years old). We divided the patients into 4 groups; Both menisci was intact (BMI, control group), lateral meniscus removed (LMR), medial meniscus removed (MMR) and both menisci removed (BMR). Anterior passive displacement (objective stability) was estimated using KT-2000 arthrometer under the loading of 15lb,20lb and 30lb and evaluated anterior drawer test, Lachman test, range of motion, thigh circumference. Functional evaluation system of IKDC, OAK and Lysholm knee score was used. Results : Average anterior displacement under the loading of 30lb were 2.47 mm, 2.96 mm, 2.96 mm and 3.57 mm in each group(BMI, LMR, MMR, BMR) and it was statistically significant difference (p<0.05). There is no statistically significant difference in average anterior displacement under the loading of 15lb and 20lb in each group but it has showed decreasing tendency in meniscal removed groups. The mean anterior displacement was within 3 mm in 21 cases, 15 cases, 24 cases and 12 cases (total 72 cases, $94\%$) under the loading of 15lb and 20 cases, 15 cases, 24 cases and 11 cases (total 70 cases, $91\%$) under the loading 20lb of in each group and postoperative knee joint stability has showed increasing tendency (p>0.05). The mean score was 94.5, 93.2, 92.2 and 90.4 points in each group and 71 cases $(91\%)$ were more than excellent or good with a OAK score and fair results were noted 4 cases in both meniscal removed group. There were 65 cases $(83\%)$ with a Lysholm knee score more than excellent or good, and IKDC grading were more than normal or nearly normal in 74 cases $(95\%)$ except 4 cases (2 cases in MMR group and 2 cases in BMR group). Conclusion : Long-term anterior stability and functional results of a successful ACL reconstruction affected by tile status of the menisci at the time of surgery and KT-2000 arthrometer was good for estimation of objective follow up.

  • PDF

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.

Suggestion of Additional Criteria for Site Categorization in Korea by Quantifying Regional Specific Characteristics on Seismic Response (지역고유 지진응답 특성 정량화를 통한 국내 부지 분류 기준의 추가 반영 제안)

  • Sun, Chang-Guk
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.203-218
    • /
    • 2010
  • The site categorization and corresponding site amplification factors in the current Korean seismic design guideline are based on provisions for the western United States (US), although the site effects resulting in the amplification of earthquake ground motions are directly dependent on the regional and local site characteristic conditions. In these seismic codes, two amplification factors called site coefficients, $F_a$ and $F_v$, for the short-period band and midperiod band, respectively, are listed according to a criterion, mean shear wave velocity ($V_S$) to a depth of 30 m, into five classes composed of A to E. To suggest a site classification system reflecting Korean site conditions, in this study, systematic site characterization was carried out at four regional areas, Gyeongju, Hongsung, Haemi and Sacheon, to obtain the $V_S$ profiles from surface to bedrock in field and the non-linear soil properties in laboratory. The soil deposits in Korea, which were shallower and stiffer than those in the western US, were examined, and thus the site period in Korea was distributed in the low and narrow band comparing with those in western US. Based on the geotechnical characteristic properties obtained in the field and laboratory, various site-specific seismic response analyses were conducted for total 75 sites by adopting both equivalent-linear and non-linear methods. The analysis results showed that the site coefficients specified in the current Korean provision underestimate the ground motion in the short-period range and overestimate in the mid-period range. These differences can be explained by the differences in the local site characteristics including the depth to bedrock between Korea and western US. Based on the analysis results in this study and the prior research results for the Korean peninsula, new site classification system was developed by introducing the site period as representative criterion and the mean $V_S$ to a depth of shallower than 30 m as additional criterion, to reliably determine the ground motions and the corresponding design spectra taking into account the regional site characteristics in Korea.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

The Effect of Meniscectomy on Clinical Result After ACL Reconstruction (전방십자인대 재건술에서 반월상 연골 절제술의 영향)

  • Cho, Hyung-Jun;Lee, Jung-Hwan;Bae, Dae-Kyung;Song, Sang-Jun;Yoon, Kyoung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • Purpose: To evaluate the effects of total or subtotal meniscectomy on anterior cruciate ligament reconstruction. Materials and Methods: We reviewed the 455 cases of arthroscopic ACLR (anterior cruciate ligament reconstruction) from February, 2003 to February, 2007 and followed-up more than 1 year. The 93 cases were enrolled. The 45 cases who underwent only ACLR were included and the 48 cases who underwent ACLR with total or subtotal meniscectomy were included in this study except grade 3 or 4 chondral lesion, partial meniscetomy or meniscal repair. We divided the patient into 4 groups which were isolated ACLR group (group I, 45cases), ACLR with lateral meniscectomy group (group II, 10cases), ACLR with medial meniscectomy group (group III, 28cases) and ACLR with both medial and lateral meniscectomy group (group IV, 10cases). The clinical evaluation was done by range of motion (ROM), IKDC subjective score, Lysholm score, anterior drawer test, Lachman test, Pivot shift test and KT-1000 arthrometer. Results: At final follow up, group IV was inferior than group I in IKDC subjective score and Lysholm score, and inferior than group II in IKDC subjective score. In KT-1000 arhtometric test, group I had better results than group III and group IV. Also in anterior drawer test and Lachman test, group 1 had better result than group III and group IV. In pivot shift test, there was no significant difference among four groups. Conclusion: Medial or both medial and lateral meniscectomy had greater laxity in anterior drawer test, Lachman test and KT-1000 arthrometric test and both medial and lateral meniscectomy had a lower subjective score than both meniscus intact group.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Accuracy and Clinical Outcomes of Ultrasound-guided Glenohumeral joint Injection: Acromioclavicular Approach in Patients with Adhesive Capsulitis (초음파를 이용한 견관절 관절강내 주사의 정확성과 임상적 결과: 유착성 관절낭염 환자의 견봉 쇄골 접근법)

  • Lhee, Sang-Hoon;Hwang, Seok-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • Purpose: The purpose of the study was to evaluate the accuracy and clinical outcome of ultrasound-guided glenohumeral joint steroid injection on adhesive capsulitis. Materials and Methods: Patients who were diagnosed as adhesive capsulitis by MRI and physical examination and did not improve their symptom with physical therapy and NSAIDS treatment more than 6 months were included in the study. Patients who showed any other shoulder pathology or history if trauma were excluded from the study. 33 patients including 15 males and 18 females were enrolled in the study, the average age being 55.1 (age 42~72). Cocktail of steroid, lidocaine, saline and contrast medium injected inside shoulder glenohumeral joint using novel approach (which we called acromioclavicular approach) under ultrasound guidance. Clinical outcome was measured through passive range of motion and VAS scoring system. Results: Based on radiographic findings, cases were classified according to the leakage of contrast medium; perfect confinement of contrast-medium inside the capsule, partial leakage of the medium and contrast-medium found at outside the joint. Total 25 cases (76%) out of 33 cases showed perfect confinement of contrast-medium inside the glenohumeral joint. Partial leakage was observed in 6 cases (18%), and contrast medium was observed outside of the glenohumeral joint in 2 cases (6%). Perfect-confinement group showed $111^{\circ}$($80{\sim}140^{\circ}$) of forward flexion and $48^{\circ}$($0{\sim}90^{\circ}$) of external rotation before injection, and improved to $134^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($30{\sim}90^{\circ}$) of external rotation after injection (p<0.01). Partial leakage showed $120^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($10{\sim}90^{\circ}$) of external rotation before injection, and improved to $139^{\circ}$($135{\sim}140^{\circ}$) of forward flexion and $78^{\circ}$($50{\sim}90^{\circ}$) of external rotation after injection (p<0.01). VAS score improved from 7.1 (score 3~9) to 2.6 (score 0~5) (p<0.01) in perfect confinement group, from 7.5 (score 7~9) to 3.3 (score 2~4) (p<0.01) in partial leakage group. Two group showed no significant difference. Conclusion: Accuracy of Acromioclavicular approach was 94% which is better than any other methods published so far. Partial leakage of the injection material did not show inferior result compared to perfect injection.

  • PDF