• Title/Summary/Keyword: total pressure

Search Result 3,980, Processing Time 0.033 seconds

Determination of Aroma Components in Pinus densiflora (Pine Needles) Studied by Using Different Extraction Methods (추출방법에 따른 솔잎의 휘발성 성분 조성 비교)

  • Lee Jae-Gon;Lee Chang-Gook;Baek Shin;Kwon Young-Ju;Jang Hee-Jin;Kwag Jae-Jin;Rhee Moon-Soo;Lee Gae-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.2
    • /
    • pp.161-168
    • /
    • 2006
  • The efficiency of six different extraction methods for the analysis of aroma components from pine needle(P. densiflora) was compared by gas chromatography-mass selective detector(GC-MSD). The six methods were dynamic headspace(DHS), reduced pressure headspace(RPHS), solid-phase microextraction(SPME), simultaneous distillation-extraction(SDE), supercritical fluid extraction(SFE) and pyrolysis distillation extraction(PDE). A total of 65 compounds were identified by using the six different extraction methods. These compounds are classified into six categories in terms of chemical functionality: 25 hydrocarbons, 16 alcohols, 9 carbonyls, 6 esters, 7 acids, and 2 ethers. The aroma compounds having low boiling point were more abundant in DHS, RPHS, and SPME extracts. On the other hand, the aroma compounds having high boiling point were more abundants in SDE, SFE and PDE extracts. The acid compounds were extracted by heat-based extraction methods such as SDE, SFE, PDE, but not by DHS, RPHS and SPME, which used neither solvent nor heat. The oxygenated terpens, hexanal, hexanol, and hexadienal were more abundant in DHS and RPHS extracts, compared with the other methods.

Predicting Mortality in Patients with Tuberculous Destroyed Lung Receiving Mechanical Ventilation

  • Kim, Won-Young;Kim, Mi-Hyun;Jo, Eun-Jung;Eom, Jung Seop;Mok, Jeongha;Kim, Ki Uk;Park, Hye-Kyung;Lee, Min Ki;Lee, Kwangha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.3
    • /
    • pp.247-255
    • /
    • 2018
  • Background: Patients with acute respiratory failure secondary to tuberculous destroyed lung (TDL) have a poor prognosis. The aim of the present retrospective study was to develop a mortality prediction model for TDL patients who require mechanical ventilation. Methods: Data from consecutive TDL patients who had received mechanical ventilation at a single university-affiliated tertiary care hospital in Korea were reviewed. Binary logistic regression was used to identify factors predicting intensive care unit (ICU) mortality. A TDL on mechanical Ventilation (TDL-Vent) score was calculated by assigning points to variables according to ${\beta}$ coefficient values. Results: Data from 125 patients were reviewed. A total of 36 patients (29%) died during ICU admission. On the basis of multivariate analysis, the following factors were included in the TDL-Vent score: age ${\geq}65$ years, vasopressor use, and arterial partial pressure of oxygen/fraction of inspired oxygen ratio <180. In a second regression model, a modified score was then calculated by adding brain natriuretic peptide. For TDL-Vent scores 0 to 3, the 60-day mortality rates were 11%, 27%, 30%, and 77%, respectively (p<0.001). For modified TDL-Vent scores 0 to ${\geq}3$, the 60-day mortality rates were 0%, 21%, 33%, and 57%, respectively (p=0.001). For both the TDL-Vent score and the modified TDL-Vent score, the areas under the receiver operating characteristic curve were larger than that of other illness severity scores. Conclusion: The TDL-Vent model identifies TDL patients on mechanical ventilation with a high risk of mortality. Prospective validation studies in larger cohorts are now warranted.

A Fully Coupled Hydrogeomechanical Numerical Analysis of Rainfall Impacts on Groundwater Flow in Slopes and Slope Stability (사면 내의 지하수 유동과 사면의 안정성에 대한 강수 영향의 완전 연동된 수리지질역학적 수치 해석)

  • 김준모
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.5-16
    • /
    • 2002
  • A hydrogeomechanical numerical model is presented to evaluate rainfall impacts on groundwater flow in slopes and slope stability. This numerical model is developed based on the fully coupled poroelastic governing equations for groundwater flow in deforming variably saturated geologic media and the Galerkin finite element method. A series of numerical experiments using the model developed are then applied to an unsaturated slope under various rainfall rates. The numerical simulation results show that the overall hydromechanical slope stability deteriorates, and the potential failure nay initiate from the slope toe and propagate toward the slope crest as the rainfall rate increases. From the viewpoint of hydrogeology, the pressure head and hence the total hydraulic head increase as the rainfall rate increases. As a result, the groundwater table rises, the unsaturated zone reduces, the seepage face expands from the slope toe toward the slope crest, and the groundwater flow velocity increases along the seepage face. From the viewpoint of geomechanics, the horizontal displacement increases, and the vertical displacement decreases toward the slope toe as the rainfall rate increases. This may result from the buoyancy effect associated with the groundwater table rise as the rainfall rate increases. As a result, the overall deformation intensifies toward the slope toe, and the unstable zone, in which the factor of safety against shear failure is less than 1, becomes thicker near the slope toe and propagates from the slope toe toward the slope crest. The numerical simulation results also suggest that the potential tension failure is likely to occur within the slope between the potential shear failure surface and the ground surface.

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

A Study on Urinary Incontinence of Elderly Women in a Community (노인여성의 요실금 실태)

  • Park, Ok-Hee;Kwon, In-Soo;Kang, Young-Sil
    • Women's Health Nursing
    • /
    • v.7 no.4
    • /
    • pp.536-546
    • /
    • 2001
  • The purposes of this descriptive study were to identify the prevalence rate of urinary incontinence(UI) and the differences in frequency of incontinent and normal women by general characteristics, obstetrical history, and the conditional events for urinary incontinence of the elderly women in a community. By the results of this study, it is intended to provide nursing practice guidelines for incontinent women. The research design of this study was a preliminary descriptive study. The 173 subjects were 55 years old and over, and resided in a small city area. Data were collected from June 20 to July 20, 2001, by an interview or a self-report with questionaire. The questionaire was composed of items of general characteristics, obstetrical characteristics, and conditions of UI by the modified Henderickon's Stress Incontinence Scale(1981). The results were summariezed as follows: 1. The UI prevalence rate of the sample was 64.2%. Of the incontinent women, 31.5% had experienced UI for a period of three to five years, and 84.7% had never treated or managed their UI. Frequency of UI was once or twice times per month(46.8%). 2. The total mean of UI on the scale in the incontinent women was 25.50 of 85, ranging from 18 to 41. 3. The most frequent condition of UI was coughing, followed by laughing, sneezing, heavy exercise, and preparation of urination in descending order. 4. There were significant differences in age, education, social activity, and urinary difficulty between the incontinent women and the normal women. 5. There were significant differences in frequency of spontaneous abortion, age of menopause between the incontinent women and the normal women. 6. There were no significant differences in number of delivery, frequency of artificial abortion, age of the last delivery, and postal health management between the incontinent women and the normal women. In conclusion, the incidence of UI in this study was high, but there were no effective treatments or management. It is suggested to provide the adult women with knowledge about UI, and to educate preventive behavior and control skill of urinary incontinence. Also episodes of urinary incontinence were high in the situation of sudden increase of abdominal pressure. This data can be used for the prevention strategy of urinary incontinence, In future research it is recommended to identify comprehensive factors related to urinary incontinence including psychosocial factors, and effective strategies of urinary incontinence.

  • PDF

Treatment of Extremely High Risk and Resistant Gestational Trophoblastic Neoplasia Patients in King Chulalongkorn Memorial Hospital

  • Oranratanaphan, Shina;Lertkhachonsuk, Ruangsak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.925-928
    • /
    • 2014
  • Background: Gestational trophoblastic neoplasia (GTN) is a spectrum of disease with abnormal trophoblastic proliferation. Treatment is based on FIGO stage and WHO risk factor scores. Patients whose score is 12 or more are considered as at extremely high risk with a high likelihood of resistance to first line treatment. Optimal therapy is therefore controversial. Objective: This study was conducted in order to summarize the regimen used for extremely high risk or resistant GTN patients in our institution the in past 10 years. Materials and Methods: All the charts of GTN patients classified as extremely high risk, recurrent or resistant during 1 January 2002 to 31 December 2011 were reviewed. Criteria for diagnosis of GTN were also assessed to confirm the diagnosis. FIGO stage and WHO risk prognostic score were also re-calculated to ensure the accuracy of the information. Patient characteristics were reviewed in the aspects of age, weight, height, BMI, presenting symptoms, metastatic area, lesions, FIGO stage, WHO risk factor score, serum hCG level, treatment regimen, adjuvant treatments, side effects and response to treatment, including disease free survival. Results: Eight patients meeting the criteria of extremely high risk or resistant GTN were included in this review. Mean age was 33.6 years (SD=13.5, range 17-53). Of the total, 3 were stage III (37.5%) and 5 were stage IV (62.5%). Mean duration from previous pregnancies to GTN was 17.6 months (SD 9.9). Mean serum hCG level was 864,589 mIU/ml (SD 98,151). Presenting symptoms of the patients were various such as hemoptysis, abdominal pain, headache, heavy vaginal bleeding and stroke. The most commonly used first line chemotherapeutic regimen in our institution was the VAC regimen which was given to 4 of 8 patients in this study. The most common second line chemotherapy was EMACO. Adjuvant radiation was given to most of the patients who had brain metastasis. Most of the patients have to delay chemotherapy for 1-2 weeks due to grade 2-3 leukopenia and require G-CSF to rescue from neutropenia. Five form 8 patients were still survived. Mean of disease free survival was 20.4 months. Two patients died of the disease, while another one patient died from sepsis of pressure sore wound. None of surviving patients developed recurrence of disease after complete treatment. Conclusions: In extremely high risk GTN patients, main treatment is multi-agent chemotherapy. In our institution, we usually use VAC as a first line treatment of high risk GTN, but since resistance is quite common, this may not suitable for extremely high risk GTN patients. The most commonly used second line multi-agent chemotherapy in our institution is EMA-CO. Adjuvant brain radiation was administered to most of the patients with brain metastasis in our institution. The survival rate is comparable to previous reviews. Our treatment demonstrated differences from other institutions but the survival is comparable. The limitation of this review is the number of cases is small due to rarity of the disease. Further trials or multicenter analyses may be considered.

A Study on Characteristics of Carbon Dioxide Emissions from Passenger Cars (승용차의 이산화탄소(CO2) 배출특성에 관한 연구)

  • Lyu Y.S.;Ryu J.H.;Jeon M.S.;Kim D.W.;Jung S.W.;Kim S.M.;Eom M.D.;Kim J.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.451-458
    • /
    • 2006
  • Automotive exhaust is suspected to be one of the major reasons of the rapid increase in greenhouse effect gases in ambient air. As the concerns regarding global worming were increased, the pressure on mobile source greenhouse gas (GHG) emission were also increased. Carbon Dioxides contribute over 90% of total GHG emission and the mobile source occupies about 20% of this $CO_2$ emission. In this study, in order to investigate $CO_2$ emission characteristics from gasoline and LPG passenger cars (PC), which is the most dominant vehicle type in Korea, 53 vehicles were tested on the chassis dynamometer. $CO_2$ emissions and fuel consumption efficiency were measured. The emission characteristics by fuel type, model year, mileage, vehicle speed and transmission type were also discussed. Test modes used in this study were NIER 10 modes and CVS-75 mode, which have been used for developing emission factors and testing new vehicles respectively. The results of this study showed that the main factors which have significant influences on the $CO_2$ emissions are fuel type, transmission type, displacement of vehicle and mileage. The correlation between $CO_2$ emission and FE was also determined by comparing $CO_2$ emission and fuel consumption efficiency. The overall results of this study will greatly contribute to domestic greenhouse gas emissions calculation and designing national strategies for climate change.

Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea (경기도 내 대기 중 다이옥신 분포 특성에 관한 연구)

  • Heo, Jong-Won;Min, Yoon-Ki;Kim, Dong-Gi;Choi, Il-Woo;Kim, Jong-Soo;Song, Il-Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.548-561
    • /
    • 2015
  • Atmospheric concentrations of polychlorinated dibezo-p-dioxins and furans (PCDD/Fs) were investigated at urban-residential (Group I: Suwon, Guri and Goyang), industrial (Group II: Ansan, Siheung and Bucheon), urban-rural mixed (Group III: Yangju, Pocheon and Dongducheon) and rural regions (Group IV: Yangpyeong) in Gyeonggi-do from February 2012 to November 2012 quarterly. The concentrations of PCDD/Fs ranged from 0.018 to $0.109pgTEQm^{-3}$ in Group I (mean value: $0.061pgTEQm^{-3}$), 0.059 to $0.367pgTEQm^{-3}$ in Group II (mean value: $0.179pgTEQm^{-3}$), 0.072 to $0.836pgTEQm^{-3}$ in Group III (mean value: $0.334pgTEQm^{-3}$) and 0.014 to $0.066pgTEQm^{-3}$ in Group IV (mean value: $0.034pgTEQm^{-3}$), respectively. In spite of the less PCDD/F emission sources than Group II (industrial regions), the level of PCDD/Fs in urban-rural mixed area showed the highest values with high fluctuation. It's likely that the Group III was affected by fugitive emissions such like biomass burning and unregulated open burning. The mean contribution of particle phase to total PCDD/F concentration was above 83% because most of PCDD/F congeners were partitioned into particle phase. We evaluated their gas-to-particles equilibriums with the regression between the particle-gas partition coefficient, $K_P(m^3{\mu}g^{-1})$ and corresponding subcooled liquid vapor pressure ($P_L$). The logarithm-$K_P$ of PCDD/Fs was poorly correlated with $P_L$ at low ambient temperature (below $10^{\circ}C$) and the slope (m) values for log-log plots of the $K_P$ vs. $P_L$ was steeper in the Group 2 and Group 3 than residential area. It implies that the slope values were likely influenced by both the direct emission source of PCDD/Fs and ambient temperature.

Effects of Long-term Exposure to Black Carbon Particles on Growth and Gas Exchange Rates of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica Seedlings

  • Yamaguchi, Masahiro;Otani, Yoko;Takeda, Kenta;Lenggoro, I. Wuled;Ishida, Atsushi;Yazaki, Kenichi;Noguchi, Kyotaro;Sase, Hiroyuki;Murao, Naoto;Nakaba, Satoshi;Yamane, Kenichi;Kuroda, Katsushi;Sano, Yuzou;Funada, Ryo;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.259-267
    • /
    • 2012
  • To clarify the effects of black carbon (BC) particles on growth and gas exchange rates of Asian forest tree species, the seedlings of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica were exposed to BC particles with sub-micron size for two growing seasons from 1 June 2009 to 11 November 2010. The BC particles deposited after the exposure to BC were observed on the foliar surface of the 4 tree species. At the end of the experiment, the amount of BC accumulated on the foliar surface after the exposure to BC aerosols were 0.13, 0.69, 0.32 and 0.58 mg C $m^{-2}$ total leaf area in F. crenata, C. sieboldii, L. kaempferi and C. japonica seedlings, respectively. In August 2010, the exposure to BC particles did not significantly affect net photosynthetic rate under any light intensity, stomatal diffusive conductance to water vapour ($g_s$), stomatal limitation of photosynthesis, response of $g_s$ to increase in vapour pressure deficit and leaf temperature under light saturated condition in the leaves or needles of the seedlings. These results suggest that the BC particles deposited on the foliar surface did not reduce net photosynthesis by shading, did not increase leaf temperature by absorption of irradiation light, and did not induce plugging of stomata in the leaves or needles of the seedlings. There were no significant effects of BC particles on the increments of plant height and stem base diameter during the experimental period and the whole-plant dry mass at the end of the experiment. These results indicate that the exposure to BC particles with sub-micron size for two growing seasons did not significantly affect the growth and leaf or needle gas exchange rates of F. crenata, C. sieboldii, L. kaempferi and C. japonica seedlings.