• 제목/요약/키워드: total hip prosthesis

검색결과 34건 처리시간 0.019초

맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출 (Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant)

  • 서정우;전용태
    • 한국CDE학회논문집
    • /
    • 제13권3호
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.

Periprosthetic Hip Joint Infection with Flavonifractor plautii: A Literature Review and Case Report

  • Alexander Wilton;Constantine Michael Glezos;Hasitha Pananwala;Han Kiong Lim
    • Hip & pelvis
    • /
    • 제34권4호
    • /
    • pp.255-261
    • /
    • 2022
  • The purpose of this case report and review of the literature is to provide documentation on periprosthetic hip joint infection with Flavonifractor plautii (formerly known as Eubacterium plautii), a strictly anaerobic bacterium, and to report on a successful pathway for management including staged surgical revisions and extended antibiotic therapy. A systematic review of the literature was conducted, which identified this case as only the fifth documented case of human infection with this organism; as a result, conduct of further research is warranted, based on the paucity of reports in the literature addressing anaerobic periprosthetic joint infection.

Numerical modeling of the damaged cement orthopedic in three variants of total hip prostheses

  • Cherfi Mohamed;Zagane Mohammed El Sallah;Moulgada Abdelmadjid;Ait Kaci Djafar;Benouis Ali;Zahi Rachid;Sahli Abderahmen
    • Structural Engineering and Mechanics
    • /
    • 제91권3호
    • /
    • pp.251-262
    • /
    • 2024
  • Numerical modeling using the finite element method (FEM) offers crucial insights into the mechanical behavior of prostheses, including stress and strain distribution, load transfer, and stress intensity factors. Analyzing cracking in PMMA surgical cement (polymethylmethacrylate) for total hip prostheses (THP) is essential for understanding the loosening phenomenon, as the rupture of orthopedic cement is a primary cause. By understanding various failure mechanisms, significant advancements in cemented total prostheses can be achieved. This study performed a numerical analysis using a 3D FEM model to evaluate stress levels in different THP models, aiming to model damage in the orthopedic cement used in total hip arthroplasty. Utilizing ABAQUS software, FEM, and XFEM, the damage in three types of THPs-Charnley (CMK3), Osteal (BM3), and THOMPSON was modeled under stumbling loading conditions. XFEM allowed for the consideration of crack propagation between the cement and bone, while the GEARING criterion employed a user-defined field subroutine to model damage parameters. The study's findings can contribute to improving implant fixation techniques and preventing postoperative complications in orthopedic surgery.

Recent updates for biomaterials used in total hip arthroplasty

  • Hu, Chang Yong;Yoon, Taek-Rim
    • 생체재료학회지
    • /
    • 제22권4호
    • /
    • pp.259-270
    • /
    • 2018
  • Background: Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods: A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'total hip arthroplasty', 'biomaterials', 'stainless steel', 'cobalt-chromium', 'titanium', 'polyethylene', and 'ceramic'. Results: The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion: This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.

스템 길이에 따른 환자맞춤 인공고관절의 역학적 안정성 비교 (Comparison of Biomechanical Stability of Custom-made Hip Implants using Finite Element Analysis)

  • 전용태
    • 한국CDE학회논문집
    • /
    • 제21권4호
    • /
    • pp.426-432
    • /
    • 2016
  • Designing a morphologically well-fitted hip implant to a patient anatomy is desirable to improve surgical outcomes since a commercial ready-made hip implant may not well conform to the patient joint. In this study, biomechanical stability of patient-specific hip implants with two different stem lengths was compared and discussed using a 3D finite element analysis (FEA). The FEA results in this study showed that an increase in stem length brings about more the peaked von-Mises stress (PVMS) in the prosthesis and less in the femur. However the decrease in von-Mises stress in the femur causes stress shielding phenomenon that usually leads to considerable bone resorption. Although, in biomechanical stability point of view, this work recommends the use of smaller stems, the length of stem must be determined by considering both the von-Mises stress and the stress-shielding phenomenon.

인공고관절의 설계인자들이 해리현상에 미치는 영향에 대한 해석 (Analysis of Loosening Phenomenon in Artificial Hip Joint Application Related to Design Parameters)

  • 김영은;정정화
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권2호
    • /
    • pp.155-162
    • /
    • 1993
  • The human's biomechanical structure keeps an optimal state by adapting the original biomechanical structure according to a change in the physical environment. This phenomenon is believed to be the main cause of loosening of the total hip replacement which is used widely in these days. In this study the bone density change due to artificial hip joint, which is generally believed as bone-remodeling, was investigated by the finite element method. For this, 2-D FEM models with 4 nodal point elements were constructed for intact and implanted cases. The density was calculated by comparing the relative amounts of effective stress for these two cases. In this way, calculated new density values were used in the next step as input values and this procedure repeated until convergence was obtained. Severe density change was detected at the femoral cortex of the proximal-medial side as expected. Moreover, following surprising result was found from this analysis. Titanium alloy prosthesis showed less density change compared to stainless steel prosthesis at earlier stage, however, almost same amount of the density change was detected at final stage. It was also found that other design parameters could not significantly affect its density change.

  • PDF

Comparison of Short Curved Stems and Standard-length Single Wedged Stems for Cementless Total Hip Arthroplasty

  • Chan Young Lee;Sheng-Yu Jin;Ji Hoon Choi;Taek-Rim Yoon;Kyung-Soon Park
    • Hip & pelvis
    • /
    • 제36권2호
    • /
    • pp.120-128
    • /
    • 2024
  • Purpose: The purpose of this study was to compare the clinical and radiographic outcomes with use of short-curved stems versus standard-length single wedged stems over a minimum follow-up period of five years. Materials and Methods: A retrospective study of primary total hip arthroplasties performed using the Fitmore® stem (127 hips, 122 patients) and the M/L taper® stem (195 hips, 187 patients) between October 2012 and June 2014 was conducted. The clinical and radiographic outcomes were obtained for evaluation over a minimum follow-up period of five years. Results: In both the Fitmore® and M/L taper® groups, the mean Harris hip score improved from 52.4 and 48.9 preoperatively to 93.3 and 94.5 at the final follow-up, respectively (P=0.980). The mean Western Ontario and McMaster Universities Osteoarthritis Index scores also improved from 73.3 and 76.8 preoperatively to 22.9 and 25.6 at the final follow-up, respectively (P=0.465). Fifteen hips (Fitmore®: 14 hips; M/L taper®: one hip, P<0.001) developed intraoperative cracks and were treated simultaneously with cerclage wiring. Radiography showed a radiolucent line in 24 hips in the Fitmore® group and 12 hips in the M/L taper® group (P=0.125). Cortical hypertrophy was detected in 29 hips (Fitmore® group: 28 hips; M/L taper® group: one hip, P<0.001). Conclusion: Similarly favorable clinical and radiographic outcomes were achieved with use of both short-curved stems and standard-length single wedged stems. However, higher cortical hypertrophy and a higher rate of femoral crack were observed with use of Fitmore® stems.

무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성 (Biomechanical characteristics of the distal filling effects in cementless femoral stem)

  • 박상석;박재원;채수원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF