• 제목/요약/키워드: total harmonic

검색결과 569건 처리시간 0.031초

Study of Harmonic Suppression of Ship Electric Propulsion Systems

  • Wang, Yifei;Yuan, Youxin;Chen, Jing
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1303-1314
    • /
    • 2019
  • This paper studies the harmonic characteristics of ship electric propulsion systems and their treatment methods. It also adopts effective measures to suppress and prevent ship power systems from affecting ship operation due to the serious damage caused by harmonics. Firstly, the harmonic characteristics of a ship electric propulsion system are reviewed and discussed. Secondly, aiming at problems such as resonant frequency and filter characteristics variations, resonance point migration, and unstable filtering performances in conventional passive filters, a method for fully tuning of a passive dynamic tunable filter (PDTF) is proposed to realize harmonic suppression. Thirdly, to address the problems of the uncontrollable inductance L of traditional air gap iron core reactors and the harmonics of power electronic impedance converters (PEICs), this paper proposes an electromagnetic coupling reactor with impedance transformation and harmonic suppression characteristics (ECRITHS), with the internal filter (IF) designed to suppress the harmonics generated by PEICs. The ECRITHS is characterized by both harmonic suppression and impedance change. Fourthly, the ECRITHS is investigated. This investigation includes the harmonic suppression characteristics and impedance transformation characteristics of the ECRITHS at the fundamental frequency, which shows the good performance of the ECRITHS. Simulation and experimental evaluations of the PDTF are carried out. Multiple PDTFs can be configured to realize multi-order simultaneous dynamic filtering, and can effectively eliminate the current harmonics of ship electric propulsion systems. This is done to reduce the total harmonic distortion (THD) of the supply currents to well below the 5% limit imposed by the IEEE-519 standard. The PDTF also can eliminate harmonic currents in different geographic places by using a low voltage distribution system. Finally, a detailed discussion is presented, with challenges and future implications discussed. The research results are intended to effectively eliminate the harmonics of ship electric power propulsion systems and to improve the power quality of ship power systems. This is of theoretical and practical significance for improving the power quality and power savings of ship power systems.

사이크로이드 치형을 이용한 하모닉 감속기의 개발 (Development of harmonic drive using cycloide tooth profile)

  • 이종원;오세훈;김준철;전한수
    • 대한기계학회논문집A
    • /
    • 제21권7호
    • /
    • pp.1166-1173
    • /
    • 1997
  • Due to progress in manufacturing techniques, the performance of the harmonic drive has been improved but not sufficiently. One of the important problems which the current harmonic drive has is that while there is the potential for having a wider tooth contact area, the total number of teeth engaged simultaneously is still small. This is mainly due to the involute tooth profile. Hence, in this study, the cycloid-type tooth profile is developed to improve this problem. This paper represents the design methodology and performance evaluation f the cycloid-type harmonic drive. Cycloide tooth profile was derived by analyzing geometry of the tooth engagement and the contact mechanisms of the tooth which were examined and analyzed by load analysis. The stress due to elastic deformation of a flexspline was also obtained by approximate formula and computer analysis. Finally, the cycloid-type harmonic drive with 1:100 speed ratio was manufactured and the performance of the harmonic drive was evaluated.

접지 임피던스가 중성선 고조파 전류에 미치는 영향 (The Ground Impedance Influence on Neutral Harmonic Currents)

  • 김경철;백승현;이일무;김종욱
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.120-127
    • /
    • 2004
  • 스위칭 모드 전원 공급 장치와 같은 비선형 부하의 증가로, 3상 4선식 배전계통을 채용하는 중성선에 많은 고조파 전류가 흐른다. 중성선은 접지 시스템과 연결되어 있기 때문에 접지 임피던스는 중성선 고조파 전류에 영향을 끼친다고 알려져 있다. 현장에서 실측한 고조파 전류와 전압으로 고조파 해석용 3상 등가 회로를 구성하였다. 실측한 값과 MATLAB으로 시뮬레이션 한 값을 수치와 파형으로 비교 검토하였다. 또한 본 논문에서는 중성선 고조파 전류와 접지 임피던스와의 관계를 시뮬레이션을 통해 검증하였다.

Robust Active LED Driver with High Power Factor and Low Total Harmonic Distortion Compatible with a Rapid-Start Ballast

  • Park, Chang-Byung;Choi, Bo-Hwan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.226-236
    • /
    • 2014
  • A new active LED driver with high power factor (PF) and low total harmonic distortion (THD) compatible with a rapid-start ballast is proposed. An LC input filter is attached to the ballast to increase PF and reduce THD. A boost converter is then installed to regulate the LED current, where an unstable operating region has been newly identified. The unstable region is successfully stabilized by feedback control with two zeroes. The extremely high overall system of the 10th order is completely analyzed by the newly introduced phasor transformed circuits in static and dynamic analyses. Although a small DC capacitor is utilized, the flicker percentage of the LED is drastically mitigated to 1% by the fast controller. The proposed LED driver that employs a simple controller with a start-up circuit is verified by extensive experiments whose results are in good agreement with the design.

가변형 수동 고조파 필터에 의한 단상 무정전전원장치의 고조파 저감에 관한 연구 (A Study on Harmonic Reduction of Single-phase UPS with Variable Passive Harmonic Filters)

  • 김성삼;황선환
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.495-501
    • /
    • 2019
  • 본 논문에서는 정류 브리지 다이오드를 갖는 단상 무정전전원장치의 전원측 고조파 및 역률 개선을 위한 가변형 고조파 필터를 제안한다. 2레벨 이상의 전력변환방식을 적용한 무정전전원장치는 전원측 고조파 및 역률 특성이 우수한 반면, 전 브리지 방식의 무정전전원장치는 전원측에 제 3고조파, 제 5고조파, 제 7고조파 및 역률 저하를 심각하게 야기한다. 이에 따라 단상 전 브리지 동작에 의해 야기된 (2n+1)차 고조파 제거 및 역률 개선을 위한 가변형 고조파 필터를 제안하고자 한다. 제안한 가변형 고조파 필터의 성능을 평가하기 위해 다양한 시뮬레이션과 실험을 진행하여 타당성을 검증하였다.

Surgical Correction of Canine Brachycephalic Syndrome Including Resection of Elongated Soft Palate and Everted Laryngeal Saccules Using Harmonic Scalpel: A Retrospective Study of 21 Cases

  • Shin, Jung-In;Kim, Minkyung;Kim, Jong-Hoon;Lee, Chaeyeong;Kim, Young-Hwan;You, Young-Sung;Lee, Dong-Bin;Lee, Jae-Hoon
    • 한국임상수의학회지
    • /
    • 제39권1호
    • /
    • pp.1-8
    • /
    • 2022
  • The current, retrospective study aimed to assess the short-term prognosis and postoperative complications associated with the surgical correction of elongated soft palate using harmonic scalpel and to compare the postoperative complications associated with the application of harmonic scalpel and traditional surgery using Metzenbaum scissors. Harmonic scalpel was used to perform staphylectomy in 21 dogs. A total of ten dogs underwent sacculectomy; six dogs with harmonic scalpel and four dogs using Metzenbaum scissors. Stenotic nares were corrected by wedge resection. Postoperative complications were recorded through monitoring and radiographic examinations. Telephone interviews were conducted on the first, third, and seventh day after discharge and continued until the resolution of postoperative complications. Postoperative edema at the surgical site was identified and mitigated within a day or two. Snoring and dyspnea improved dramatically in the group that underwent staphylectomy alone. Moreover, three dogs presented with postoperative gastrointestinal complications, especially retching. The symptoms persisted for seven days and ten days in two dogs that underwent sacculectomy with harmonic scalpel and for two days in one dog that underwent sacculectomy with Metzenbaum scissors. The clinical signs and symptoms of brachycephalic syndrome disappeared without recurrence. Harmonic scalpel provides a hemostatic effect during staphylectomy, is convenient, and does not cause postoperative complications. Conversely, the use of harmonic scalpel during sacculectomy necessitated a longer period for the resolution of complications without any significant hemostatic efficacy, compared to traditional surgery.

확률론적 방법을 이용한 교류 고속철도 시스템의 고조파 해석 (Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach)

  • 송학선;이준경;김진오;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.782-787
    • /
    • 2005
  • Magnitude of generated harmonic currents along with the operation of AC traction has nonlinear characteristics, and generated harmonic currents for high speed traction are more and more in high speed railroad(HSR) systems, especially. This paper presents probabilistic approximation method for the harmonic currents analysis about the operating speed of AC traction. To use probabilistic method for HSR system, probability density function(PDF) for collected operating speed based measure data is calculated. Mean and variance of harmonic currents of single traction are obtained based on the operating speed PDF and electrical traction model. The results of Monte Carlo Simulation(MCS) are in well accordance with the experimental and analytic methods. The harmonics of different number of trainloads are systematically investigated. It is assessed by the total demand distortion(TDD) for the HSR system.

  • PDF

ISG용 매입형 영구자석 동기 전동기 무부하 선간 역기전력 고조파 저감설계 (The Harmonic Reduction Design of IPMSM No-load line-line Back-EMF for ISG)

  • 이진규;정재우;김성일;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.754-755
    • /
    • 2008
  • This paper presents a method for reducing the Total Harmonic Distortion(THD) of line-line back_EMF of the IPMSM with distributed winding under the no-load condition. Firstly, the specific harmonic components of line-line back EMF are reduced considering with winding factor. Secondly, THD of line-line back EMF is minimized according to change of pole angle using by Space harmonic Analysis. Finally, the optimal design for minimizing the THD is conducted using response surface methodology with finite element analysis. The validity of the design method dealt with in this paper is demonstrated by comparison between the THD of optimal model and initial model.

  • PDF

능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식 (A New Injection Method of Harmonic Compensation Current by Active AC Power Filter)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감 (Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source)

  • 정영국
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.