A Study on the Method about the Economic Feasibility Estimation Considering Renewable Energy (신재생에너지원을 고려한 집단에너지 경제성평가 방법론에 관한 연구)

  • Shin, Hye-Kyeong;Choi, Young-Jun;Choi, In-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.372-374
    • /
    • 2008
  • Korea classified into a development country when UNFCCC was concluded in 1995. So Korea doesn't have a GHG reduction duty until 2012. As the UNFCCC is strengthened, recently there is a growing interest in renewable energy and energy usage efficiency improvement for reducing GHG emission. It is associated with CES and renewable energy. CES is a total energy (heat, cooling and power)supplier in aggregated demand zone like a hotel, building, hospital and redevelopment district using CHP and it improves energy usage efficiency. At present, renewable energy is needed for GHG reduction duty but renewable energy doesn't have economic feasibility. So renewable energy is needed various support system to popularize which is a FIT and RPS. Especially RPS is carrying out instead of FIT in many advanced country and it will be inroduced in Korea. RPS is a duty which electricity service provider must guarantee renewable energy as much as specific ratio of total capacity. Therefore this study conducts an economic feasibility estimation of CES considering renewable energy when RPS will introduced in the future.

  • PDF

A Study on the Flow Characteristics in T-type Rectangular Duct (T-TYPE 사각덕트내의 유동특성 연구)

  • Lee, Haeng-Nam;Park, Gil-Moon;Lee, Duck-Gu
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.702-707
    • /
    • 2001
  • The characteristics of flow in dividing regions are precise, therefore their classification is very important not only in industry but also in hydrodynamics. By now, many studies of flow in dividing regions have been performed, but flow characteristics that use visualization in dividing regions have not been studied. The present study of the PIV and the CFD exhibit average velocity distributions, kinetic energy distributions and total pressure distributions etc of the total flow field due to the development of the accurate visualization optical laser and of optical equipment. Also, PIV is accurate with the flows characteristics of the dividing region as continuous analysis is done using input equipment. The study analyzes average velocity vector field, average kinetic energy, x-axis stress distributions, average and total pressure distributions of dividing regions with flow for visualization of the PIV and the CFD measurement in a dividing rectangular duct.

  • PDF

The effect of dietary intake and anthropometric parameters on the plasma lipid level (성인의 영양소 섭취상태 및 체위와 혈액내 지방수준과의 상관관계에 관한 연구)

  • 이경애
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.6
    • /
    • pp.89-97
    • /
    • 1995
  • This study was undertaken to examine the correlations between dietary intakes or anthropometric parameters and the plasma lipid level. measurements of dali nutrients intake, body weight, height, body bass index, skinfold thickness, blood pressure, plasma total lipid, triglyceride and cholesterol were made to each of 124 healthy adult(25-59yrs) : 56 males and 65 females. The mean energy and nutrients intake, anthropometric parameters and plasma lipid levels were all in normal range. In females, the fat and protein intake, the amount and percents to total energy intake, had positive association with the plasma total lipid, but the energy percent from carbohydrate intake was correlated negatively. And body mass index positively correlated with plasma total lipid level, in male and female, Therefore we could postulated the dietary fat intake and body mass index affected to plasma lipid levels in normal conditions of healthy adult.

  • PDF

Study on Energy Independence Plan for Sewage Treatment Plant (하수처리시설의 에너지 자립화 방안 연구)

  • Kim, Young-Jun;Lee, Jong-Yeon;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.49-55
    • /
    • 2010
  • The objectives of this study are to analyze the energy independence plan and to propose a suitable sewage treatment plant in Korea. The total amount of electricity consumption for public sewage treatment plant was estimated as 1,812 GWh in 2007. It was estimated that total 16 sewage treatment plants with renewable energy systems produced electricity of 15 GWh per year, which could replace 0.8% of total electricity used for sewage treatment. It was found that domestic sewage treatment plants with power generation plants by digestion gas were installed in 7 places and produced electricity of 13 GWh per year. It was also found that the power generation plants by digestion gas were the most cost-effective for sewage treatment plant out of the renewable energy systems based on the benefit-cost analysis.

Thermal Stability of Nanostructured Synthetic Ferrimagnets under Applied Magnetic Fields in the 45˚ Direction

  • Han, C.W.;Han, J.K.;Lim, S.H.
    • Journal of Magnetics
    • /
    • v.15 no.3
    • /
    • pp.116-122
    • /
    • 2010
  • An accurate analytical equation for the total energy in the framework of the single domain model is used to study the thermal stability of nanostructured synthetic ferrimagnets. Elliptical cells are considered that have lateral dimensions of 160 nm (long axis)$\times$80 nm (short axis) and varying values of thickness asymmetry for the two magnetic layers. The direction of the applied magnetic field, which points to the $45^{\circ}$ direction, is in the opposite direction to the thicker layer magnetization. A significant difference is observed in the applied magnetic field dependencies of the equilibrium magnetic configuration and the magnetic energy barrier when using the simplifying assumption that the self-demagnetizing field is identical in magnitude to the dipole field. At a small thickness asymmetry of 0.2 nm, for example, the magnetic energy barrier is reduced from 68 kT (T=300 K) to 6 kT at the remanent state and a progressive switching behavior changes into a critical behavior, as the simplifying assumption is used. The present results clearly demonstrate the need for an accurate analytical equation for the total energy in predicting the thermal stability of nanostructured synthetic ferrimagnets.

Rovibrational Energy Transitions and Coupled Chemical Reaction Modeling of H+H2 and He+H2 in DSMC

  • Kim, Jae Gang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.347-359
    • /
    • 2015
  • A method of describing the rovibrational energy transitions and coupled chemical reactions in the direct simulation Monte Carlo (DSMC) calculations is constructed for $H(^2S)+H_2(X^1{\Sigma}_g)$ and $He(^1S)+H_2(X^1{\Sigma}_g)$. First, the state-specific total cross sections for each rovibrational states are proposed to describe the state-resolved elastic collisions. The state-resolved method is constructed to describe the rotational-vibrational-translational (RVT) energy transitions and coupled chemical reactions by these state-specific total cross sections and the rovibrational state-to-state transition cross sections of bound-bound and bound-free transitions. The RVT energy transitions and coupled chemical reactions are calculated by the state-resolved method in various heat bath conditions without relying on a macroscopic properties and phenomenological models of the DSMC. In nonequilibrium heat bath calculations, the state-resolved method are validated with those of the master equation calculations and the existing shock-tube experimental data. In bound-free transitions, the parameters of the existing chemical reaction models of the DSMC are proposed through the calibrations in the thermochemical nonequilibrium conditions. When the bound-free transition component of the state-resolved method is replaced by the existing chemical reaction models, the same agreement can be obtained except total collision energy model.

Interference Management Algorithm Based on Coalitional Game for Energy-Harvesting Small Cells

  • Chen, Jiamin;Zhu, Qi;Zhao, Su
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.9
    • /
    • pp.4220-4241
    • /
    • 2017
  • For the downlink energy-harvesting small cell network, this paper proposes an interference management algorithm based on distributed coalitional game. The cooperative interference management problem of the energy-harvesting small cells is modeled as a coalitional game with transfer utility. Based on the energy harvesting strategy of the small cells, the time sharing mode of the small cells in the same coalition is determined, and an optimization model is constructed to maximize the total system rate of the energy-harvesting small cells. Using the distributed algorithm for coalition formation proposed in this paper, the stable coalition structure, optimal time sharing strategy and optimal power distribution are found to maximize the total utility of the small cell system. The performance of the proposed algorithm is discussed and analyzed finally, and it is proved that this algorithm can converge to a stable coalition structure with reasonable complexity. The simulations show that the total system rate of the proposed algorithm is superior to that of the non-cooperative algorithm in the case of dense deployment of small cells, and the proposed algorithm can converge quickly.

Time Series Analysis of Crystalline Silicon Photovoltaic Module Certification Results (결정질 실리콘 태양광발전모듈 인증 실적의 시계열 분석)

  • Han, Yun-Cheol;Kim, Ik-Pyo;Kang, Kyu-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.33-45
    • /
    • 2017
  • Crystalline silicon photovoltaic module certification began in 2007. "Renewable Energy Equipment Certification Scheme" was implemented until July 28, 2015. Then, the scheme was changed to "KS Certification Scheme" since July 29, 2015. A total of 2,331 models have been certified by 2016. The proportion of multi crystalline modules in certified products is higher than that of mono crystalline modules, and Korean modules account for 78% of the total certification modules. Chinese solar cells account for the highest percentage of 40% of the total modules and 62.4% of modules certified in 2016 use Chinese solar cells. With the development of technology, module power is continuously increasing, and efficiency is also rising. The average efficiency of mono crystalline module is 0.74% higher than the average of multi crystalline module. As a result of comparing domestic module with Chinese module, the highest efficiency of mono crystalline module and multi crystalline module and the average efficiency of mono crystalline module are higher than those of Chinese module, but the average efficiency of multi crystalline module is similar to that of Chinese module.

The Analysis of Activity Energy, Total Energy, and Estimated Energy Expenditures in 5th and 6th Grade Primary School Students (초등학교 5, 6학년 남녀학생의 활동에너지 소비량 및 에너지필요추정량 분석)

  • Kim, Mi-Jeong;Na, Hyeon-Ju;Kim, Young-Nam
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.2
    • /
    • pp.195-205
    • /
    • 2011
  • This study was conducted to investigate the time spent, activity coefficient and energy expenditure on 7 different types of activity. Total of 386 5th and 6th grade primary school boys and girls in Seoul participated in this study. The participants spent 8 hrs for rest, 4 hrs for out of school study, 3 hrs for leisure, 1 hr 45 mins. for hygiene, 1 hr for commute, and 15 mins. for house choir activity in the day of 6 class hours. The average activity coefficient of 1 day for boys and girls were 1.69 and 1.64, respectively. The TEEs were 2,382 kcal and 2,050 kcal for boys and girls, respectively. The energy cost for study related activity (in school and study activities) was 40% of the TEE, and for rest 20%, for commute 9%, and for hygiene 10% of the TEE. The energy cost for house choir was only about 2% of TEE. The 91.2% participant's EER was higher than the EER shown in the table of 2010 DRI for Koreans. When the participant's EER was compared with the energy allowance calculated by the method in 2000 RDA for Korean, 81.6% was in the range of ${\pm}5%$, and the correlation coefficients between the 2 values were 0.981 for boys and 0.978 for girls, which means high agreements.

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.