• Title/Summary/Keyword: total energy

Search Result 6,992, Processing Time 0.041 seconds

Study of Enhancing Dye Affinity of Fabric using Microwave

  • Kim, Ji-Hyun;Choi, In-Ryu
    • The International Journal of Costume Culture
    • /
    • v.13 no.1
    • /
    • pp.62-66
    • /
    • 2010
  • Of all the ways that energy is consumed within textile industry, few are as high energy-expending as dyeing process. The energy consumption in dyeing process amounts to 77% of total fuel consumption, 54% of total electricity use. A technical development in terms of efficient saving energy and time as well is required in the process of dyeing textiles. Recently, dyeing experts are investigating new technologies can conserve energy grafting into microwaves, radio waves, infrared lights, etc. Dyeing industry in Korea, however, the research related to energy conservation has been rarely conducted. Accordingly, this study aims to examine the possibility where especially microwaves could be applied to reduce the energy use and enhance dyeing process skill. This study performs the experiment in which microwave is employed as heating condition in dyeing and figures out as color yield being promoted, bathochromic effect would be achieved. Applying microwaves in dyeing process is expected to lower the carbon emission, energy and time wasted, ultimately exalt economic efficiency.

  • PDF

Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings (마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community (농어촌지역 미활용에너지의 부존량과 이용 가능량 분석)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Kim, Jin-Wook;Lee, Yong-Uk;Bae, Sung-Don;Chae, Kap-Byung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.

Effects of supplemental glycerol polyethylene glycol ricinoleate in different energy density diets on the growth performance, blood profiles, nutrient utilization, and excreta gas emission of broilers: focus on dietary glycerol polyethylene glycol ricinoleate in broilers

  • Yin, Jia;Yun, Hyeok Min;Kim, In Ho
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.2
    • /
    • pp.219-228
    • /
    • 2018
  • This study evaluated the effects of glycerol polyethylene glycol ricinoleate (GPGR) supplementation in different energy density diets on the growth performance, blood profiles, excreta gas emission, and total tract apparent retention (TTAR) of nutrients in broilers. A total of 544 one-day-old male Ross broilers were used in a 35-day trial. The broilers were allocated into one of four treatment groups in a $2{\times}2$ factorial arrangement with two levels of energy densities (a normal energy or decreased energy density) and GPGR (0 and 0.035%). From day 18 to 35, the GPGR supplemented and normal energy density diet groups showed a significantly improved (p < 0.05) body weight gain (BWG). Meanwhile, the GPGR supplemented diet group had a significantly reduced (p < 0.05) feed conversion ratio (FCR) compared to that of the non-supplemented diet group. From day 0 to 35, the GPGR supplemented diet and the normal energy density diet groups had a significantly increased (p < 0.01) BWG and a reduced (p < 0.01) FCR. Moreover, GPGR supplementation tended to increase (p < 0.1) the TTAR of the dry matter (DM) compared with the non-supplemented diets. Likewise, the normal energy density diets had a significantly improved TTAR for the gross energy (GE) (p < 0.05) than that of the decreased energy density diets. No interactive effects were observed between the energy density and GPGR supplemented diets. In conclusion, both dietary GPGR supplementation and normal energy density diets had beneficial effects on the growth performance of broiler chickens without any adverse effects on blood profiles and excreta gas emission.

Enteric methane emissions, energy partitioning, and energetic efficiency of zebu beef cattle fed total mixed ration silage

  • Subepang, Sayan;Suzuki, Tomoyuki;Phonbumrung, Thamrongsak;Sommart, Kritapon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.4
    • /
    • pp.548-555
    • /
    • 2019
  • Objective: The main objective of this study was to evaluate the effect of different feeding levels of a total mixed ration silage-based diet on feed intake, total tract digestion, enteric methane emissions, and energy partitioning in two beef cattle genotypes. Methods: Six mature bulls (three Thai natives, and three Thai natives - Charolais crossbreeds) were assigned in a replicated $3{\times}3$ Latin square design, with cattle breed genotype in separate squares, three periods of 21 days, and three energy feeding above maintenance levels (1.1, 1.5, and 2.0 MEm, where MEm is metabolizable energy requirement for maintenance). Bulls were placed in a metabolic cage equipped with a ventilated head box respiration system to evaluate digestibility, record respiration gases, and determine energy balance. Results: Increasing the feeding level had no significant effect on digestibility but drastically reduced the enteric methane emission rate (p<0.05). Increasing the feeding level also significantly increased the energy retention and utilization efficiency (p<0.01). The Thai native cattle had greater enteric methane emission rate, digestibility, and energy utilization efficiency than the Charolais crossbred cattle (p<0.05). The daily metabolizable energy requirement for maintenance in Thai native cattle ($388kJ/kg\;BW^{0.75}$, where $BW^{0.75}$ is metabolic body weight) was 15% less than that in Charolais crossbred cattle ($444kJ/kg\;BW^{0.75}$). Conclusion: Our results suggested that the greater feeding level in zebu beef cattle fed above maintenance levels resulted in improved energy retention and utilization efficiency because of the reduction in enteric methane energy loss. The results also indicated higher efficiency of metabolisable energy utilization for growth and a lower energy requirement for maintenance in Bos indicus than in Bos taurus.

Bone Mineral Density of Korean Mother-daughter Pairs : Relations to Anthropometric Measurement, Body Composition, Bone Markers, Nutrient Intakes and Energy Expenditure (모녀간의 골밀도 : 신체 측정치 및 체조성, 골지표, 영양소 섭취량 및 에너지 소비량과의 관계)

  • 이희자
    • Journal of Nutrition and Health
    • /
    • v.29 no.9
    • /
    • pp.991-1002
    • /
    • 1996
  • The objectives of this study were to obtain normative data for 45 mother-daughter pairs on spine, femur(neck, ward's triangle, trochanter) and total body BMD (bone mineral density) measured by dual energy X-ray absorptiometry, anthropometric measurement, body composition, biochemical markers, nutrient intakes and energy expenditure, to determin the interrelations of these factors within each group, to measure familial resemblance for each variable. We observed significantly positive correlations between height, weight, head, hip and calf circumferences, tricep, femur and calf skinfold thickness, total lean body mass(=weight-total fat body mass-bone mineral content), protein and fat intakes, Ca index, serum total protein and albumin of monter-daughter pairs(p<.05-p<.001). Among mothers, age, osteocalcin, higher, weight, Ca and energy intakes were predictors of BMDs. Among daughters, weight and energy intake were predictors of BMDs. The BMD in lumbar spine(r=.48, p<.01), femoral neck(r=.38, p<.05), ward's triangle(r=.36, p<.05) of the mothers were significantly correlated with those of the daughters, after adjustment for mother's age, hight, weight, osteocalcin, Ca and energy intakes and daughter's weight, energy intake. In regression analyses, mother's BMD also were positively associated with daughter's BMD in lumbar spine, femoral neck, ward's triangle. Our findings support that mothers with low BMD tended to have daughters with low BMD. In the age groups studied, as well genetic factors as environmental factors may have an important role in determining BMD. This study suggests that women may successfully enhance their genetically determined BMD through adequate nutrient intakes and weight bearing exercise.

  • PDF

A Study on Building Energy Demand for Design of Energy System on Green Home Apartment (그린홈 공동주택의 최적 에너지 공급시스템 설계를 위한 부하 예측 연구)

  • Park, Jae-Wan;Yoon, Jong-Ho;Kwak, Hee-Youl;Lee, Jae-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.24-31
    • /
    • 2013
  • More than 23% of total nation's energy is consumed by residential building and 57.2% of Korean people are living in apartment. This study was carried out to two kind of process. First, after selecting one standard apartment, our research team investigate realistic energy consumption. Second, using 3-dimension heat transfer tool(TRISCO RADICON) and building energy simulation tool(Visual DOE) As a result, amount of heating and hot-water energy is composed of above 80 percent in standard apartment. And, after applying high performance technologies to standard apartment, namely, after being green home apartment, total energy consumption is reduced by54.6 percent. Also, because of energy consumption characteristics of green home apartment, for making more high performance green home apartment, especially, we have to figure out effective method to reduce electric and hot water energy.

The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program (동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.

Input energy spectra and energy characteristics of the hysteretic nonlinear structure with an inerter system

  • Wang, Yanchao;Chen, Qingjun;Zhao, Zhipeng;Hu, Xiuyan
    • Structural Engineering and Mechanics
    • /
    • v.76 no.6
    • /
    • pp.709-724
    • /
    • 2020
  • The typical inerter system, the tuned viscous mass damper (TVMD), has been proven to be efficient. It is characterized by an energy-dissipation-enhancement effect, whereby the dashpot deformation of TVMD can be amplified for enhanced energy dissipation efficiency. However, existing studies related to TVMD have mainly been performed on elastic structures, so the working mechanism remains unclear for nonlinear structures. To deal with this, an energy-spectrum analysis framework is developed systematically for classic bilinear hysteretic structures with TVMD. Considering the soil effect, typical bedrock records are propagated through the soil deposit, for which the designed input energy spectra are proposed by considering the TVMD parameters and structural nonlinear properties. Furthermore, the energy-dissipation-enhancement effect of TVMD is quantitatively evaluated for bilinear hysteretic structures. The results show that the established designed input energy spectra can be employed to evaluate the total energy-dissipation burden for a nonlinear TVMD structure. Particularly, the stiffness of TVMD is the dominant factor in adjusting the total input energy. Compared with the case of elastic structures, the energy-dissipation-enhancement effect of TVMD for nonlinear structures is weakened so that the expected energy-dissipation effect of TVMD is replaced by the accumulated energy dissipation of the primary structure.