• 제목/요약/키워드: total energy

검색결과 6,943건 처리시간 0.032초

정상체중 성인과 과체중 성인의 에너지 섭취량, 휴식대사량, 활동대사량 비교연구 (A Comparison of Energy Intake and Energy Expenditure in Normal-Weight and Over-Weight Korean Adults)

  • 박정아;김기진;윤진숙
    • 대한지역사회영양학회지
    • /
    • 제9권3호
    • /
    • pp.285-291
    • /
    • 2004
  • The purpose of this study was to compare the energy expenditure and energy intake of normal-weight and overweight Korean adults. We recruited 242 adults to determine resting energy expenditure, physical activity and energy intake. Resting energy expenditure was measured by indirect calorimetry. Energy intake for consecutive two days was assessed by 24 hour recall method. Daily activity pattern for 24 hour was collected from each subject. Body weight, lean body mass and percentage body fat were measured by INBODY 3.0. The subject were divided into normal ($20\leqBMI$ < 25) and overweight ($BMI \geq 25$) groups by BMI. There was no significant difference in intake of energy between two groups. Energy intake of each group was lower than the 7th Korean RDA of energy. Overweight subjects showed significantly lower REE/kg body weight. However, REE/kg lean body mass (LBM) did not differ between the two groups. Total activity energy was significantly higher in the overweight group compared to the normal group. Daily activity coefficient of overweight group in male was lower than that of normal group. Daily activity coefficient was almost same in two female groups. LBM was highly correlated with REE and total energy expenditure. We concluded that the overweight group consumed more energy than the normal group due to the heavier body weight.

생활폐기물 고형연료(RDF) 제조기술 경제성 평가 (An Economic Evaluation of MSW RDF Production Plant)

  • 최연석;최항석;김석준
    • 신재생에너지
    • /
    • 제7권1호
    • /
    • pp.29-35
    • /
    • 2011
  • The waste treatment fee and energy production effect of Wonju city RDF plant, the first RDF manufacturing plant in Korea, were investigated in the study. All plant operation data, like total weight of received wastes, produced RDF and separated rejects in processes were fully recorded for mass balance calculation of the plant in 2009. Also all consumed oil and electricity were recorded for energy balance calculation. The results showed that the waste treatment fee not including the RDF sales price of 25,000 won/ton-RDF was 116,573 won/ton-MSW and it went down to 105,298 won when included the RDF price. Produced RDF was 40.2% of total received waste in weight. Three components analysis by mass balance calculation of total received waste showed that Wonju city's MSW was 32.4% of combustible, 37.5% of water and 30.1% of incombustible respectively. Energy effect was found that total amount of produced energy was about 4 times more than that of consumed energy.

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

온실내 잉여 태양에너지 산정 (I) - 1-2W형을 중심으로 - (Estimation of Surplus Solar Energy in Greenhouse (I) - Case Study Based on 1-2W Type -)

  • 서원명;배용한;유영선;이성현;윤용철
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.79-86
    • /
    • 2009
  • This research performed to analyze surplus solar energy, which is generated from a greenhouse during daytime, and to make the basic materials for designing thermal energy storage system for surplus solar energy. For this goal, it analyzed the surplus solar energy coming from two types of greenhouse. The results of this research are as per the below: In the case of 1-2W-type greenhouse, this research gave the same temperature and ventilation condition regardless of regions, but it was judged that the quantity of surplus solar energy could be greatly changed, depending on the energy consumed for the photosynthesis and evapotranspiration of crops in the greenhouse, on the heating temperature during daytime and night, on the existence/non-existence of a curtain and its warming effect, and on the ventilation temperature suitable for the overcoming of high temperature troubles or for the optimum cultivation temperature. In the case of a single-span greenhouse, there was a big difference in energy incoming and outgoing by month, but throughout seasons, 85.0 % of the total energy put into the greenhouse was solar energy and the energy input by heating was just 15.0 % of the total. 26.4 % of the total energy input for the greenhouse was used for photosynthesis and evapotranspiration of crops, and 44.2 % of the remaining 73.6 % went out in the form of radiant heat through the surface of the greenhouse. That is, 25.2 % of the total energy loss was just the surplus solar energy. 67.6 % of the total heating energy was concentrically used for 3 months from December to February next year, but the surplus solar energy during the same period was just 19.4 % of the total annual quantity so it was found that the given condition was more restrictive in directly converting the surplus heat into greenhouse heating. Under the disadvantageous circumstance of 3 months from December to February next year, it was possible to supplement 28 % (December) $\sim$ 85 % (February) of heating energy with surplus solar energy.

Preliminary Study on the Total Dissolved Organics Measurement and Their Contribution to Conductivities at Elevated Temperature

  • Kim, Kwang-Rag;Kang, Hee-Suk;Park, Seung-Woo;Lee, Sung-Ho;Ahn, Do-Hee;Lee, Han-Soo;Hongsuk Chung;Sung, Ki-Woung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.127-132
    • /
    • 1996
  • Total organic carbon (TOC) derived from organics is one of tile possible contamination in the reactor water system and causes of pH change and high conductivity levels. Measurements of total dissolved oxidizable carbon were carried out and its contribution to conductivities at elevated temperature was studied by using tile thermodynamic equilibrium analysis in carbonic acid system. The calculated conductivities were in good agreement with tile levels observed for tile formation of carbonic acid from salicylic acid solution.

  • PDF

농촌형 녹색마을 내 신재생에너지 활용에 따른 $CO_2$ 저감 효과 (Effect of by New and Renewable Energy Utilization on $CO_2$ Reduction in Rural-type Green Village)

  • 김종구;유영선;강연구;김영화;장재경;김현태;이승기
    • 유기물자원화
    • /
    • 제20권2호
    • /
    • pp.44-52
    • /
    • 2012
  • 본 연구에서는 고유가 시대의 대안으로 정부에서 추진하고 있는 농촌형 녹색마을에 재생에너지를 도입하는 경우 $CO_2$ 저감효과를 분석하고, 재생에너지의 보급 활성화 방안을 제시하고자 하였다. 전라북도 G시에 조성하고 있는 소규모 농촌형 녹색마을의 에너지 잠재량을 조사한 결과 태양에너지를 이용하면 연간 6.73 GWh의 전력생산이 가능하고, 바이오매스로는 연간 134.06 GWh의 전략생산이 가능한 것으로 분석되었다. 따라서 전체 전력생산량은 연간 233.19 GWh로서 대상지역에서 연간 사용하고 있는 총 에너지 소비량 705.80 GWh의 33%를 부담할 수 있는 것으로 판단되었다. 한편 이산화탄소 감축잠재량을 산정한 결과 농산부산물은 1,891 ton_$CO_2$, 축산폐기물은 43,635 ton_$CO_2$, 도시폐기물은 395 ton_$CO_2$, 임산부산물은 50,324 ton_$CO_2$로 분석되었으며, 바이오매스로 인한 효과는 연간 총 96,245 ton_$CO_2$ 으로 나타났다. 또한 태양광에너지 2,251 ton_$CO_2$, 태양열에너지 1,383.3 ton_$CO_2$로 태양에너지로 인한 효과는 3,634 ton_$CO_2$이었으며, 총 99,879 ton_$CO_2$의 배출을 감축할 수 있는 것으로 나타났다.

제조업체의 에너지성과지표 고도화에 관한 연구 (A Study on the Development of the Advanced Energy Performance Indicator for the Manufacturing Companies)

  • 노경완;송명호
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.31-38
    • /
    • 2015
  • It is important to improve the energy performance in the industrial sector, and therefore most of the manufacturing companies need the energy performance indicators to identify the target and to verify the energy savings. However, the conventional energy performance indicators such as the total energy consumption and the energy intensity are not proper to use. The reason is that they do not consider adequate relevant variables including productions in the boundary of the manufacturing companies. Therefore, the study provides the advanced energy performance indicator using by the linear regression model according to each energy source to manage the target and to verify the energy performance properly.

Impact Energy Absorption Mechanism of Largely Deformable Composites with Different Reinforcing Structures

  • Kang, Tae-Jin;Kim, Cheol
    • Fibers and Polymers
    • /
    • 제1권1호
    • /
    • pp.45-54
    • /
    • 2000
  • Impact behaviors of the large deformable composites of Kevlar fiber reinforced composites of different preform structures have been investigated. An analytic tool was developed to characterize the impact behavior of the Kevlar composites. The image analysis technique, and deply technique were employed to develop energy balance equation under impact loading. An energy method was employed to establish the impact energy absorption mechanism of Kevlar multiaxial warp knitted composites. The total impact energy was classified into four categories including delamination energy, membrane energy, bending energy and rebounding energy under low velocity impact. Membrane and bending energy were calculated from the image analysis of the deformed shape of impacted specimen and delamination energy was calculated using the deplying technique. Also, the impact behavior of Kevlar composites under high velocity impact of full penetration of the composite specimen was studied. The energy absorption mechanisms under high velocity impact were modelled and the absorbed energy was classified into global deformation energy, shear-out energy, deformation energy and fiber breakage energy. The total energy obtained from the model corresponded reasonably well with the experimental results.

  • PDF

통합수요관리 효과분석을 위한 한국형 Energy System Management 모형 개발에 관한 연구 (A study on Development of Korean - Energy System Management Model for Effect Analysis of Integrated Demand Management)

  • 김용하;조현미;김의경;유정희;김동근;우성민
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1103-1111
    • /
    • 2011
  • This paper is developed to Energy Balance Flow show the flow of total energy resource be used nationally. The Energy Balance Flow is applicable of demand management factor through the analysis of foreign energy model of supply and demand and energy statistic data in the country. This study is based on and developed to Energy system management model is able to appraisal efficient of energy cost cutting, CO2 emission reduction and Energy saving at the national level calculated effect reached amount of primary energy to change of energy flow followed application of demand side management factor is able to appraisal quantitatively at the total energy to model of demand and supply.

평판형 태양열 집열기의 연중 열적 성능의 모델링 해석 (Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year)

  • 김규덕;박배덕;김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.