• Title/Summary/Keyword: total dose

Search Result 3,162, Processing Time 0.034 seconds

A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field (고방사선장내 작업 로봇용 이중 방사선 감지 시스템)

  • Lee Nam-Ho;Cho Jai-Wan;Kim Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.

Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Kang, SungHee;Cho, Jin Dong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.39-44
    • /
    • 2017
  • This study aims to analyze dose distribution and treatment time of endobronchial brachytherapy (EBBT) by changing the position step size of the dwell position. A solid water phantom and an intraluminal catheter were used in the treatment plan. The treatment plans were generated for 3, 5, 7, and 10 cm treatment lengths, respectively. For each treatment length, the source position step sizes were set as 2.5, 5, and 10 mm. Three reference points were set 1 cm away from the central axis of the catheter, along the axis, for uniform dose distribution. Volumetric dose distribution was calculated to evaluate the dosimetric effect. The total radiation delivery time and total dwell time were estimated for treatment efficiency, which were increased with position step sizes. At half-life time, the differences between the position step sizes in the total radiation delivery time were 18.1, 15.4, 18.0, and 24.0 s for 3, 5, 7, and 10 cm treatment lengths, respectively. The dose distributions were more homogenous by increasing the position step sizes. The dose difference of the reference point was less than 10%. In brachytherapy, this difference can be negligible. For EBBT, the treatment time is the key factor while considering the patient status. To reduce the total treatment time, EBBT can be performed with 2.5 mm position step size.

Anisotropic Total Variation Denoising Technique for Low-Dose Cone-Beam Computed Tomography Imaging

  • Lee, Ho;Yoon, Jeongmin;Lee, Eungman
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.150-156
    • /
    • 2018
  • This study aims to develop an improved Feldkamp-Davis-Kress (FDK) reconstruction algorithm using anisotropic total variation (ATV) minimization to enhance the image quality of low-dose cone-beam computed tomography (CBCT). The algorithm first applies a filter that integrates the Shepp-Logan filter into a cosine window function on all projections for impulse noise removal. A total variation objective function with anisotropic penalty is then minimized to enhance the difference between the real structure and noise using the steepest gradient descent optimization with adaptive step sizes. The preserving parameter to adjust the separation between the noise-free and noisy areas is determined by calculating the cumulative distribution function of the gradient magnitude of the filtered image obtained by the application of the filtering operation on each projection. With these minimized ATV projections, voxel-driven backprojection is finally performed to generate the reconstructed images. The performance of the proposed algorithm was evaluated with the catphan503 phantom dataset acquired with the use of a low-dose protocol. Qualitative and quantitative analyses showed that the proposed ATV minimization provides enhanced CBCT reconstruction images compared with those generated by the conventional FDK algorithm, with a higher contrast-to-noise ratio (CNR), lower root-mean-square-error, and higher correlation. The proposed algorithm not only leads to a potential imaging dose reduction in repeated CBCT scans via lower mA levels, but also elicits high CNR values by removing noisy corrupted areas and by avoiding the heavy penalization of striking features.

A Study for Dose-Reduction of Antipsychotics in Chronic Schizophrenics (만성 정신분열병 환자에서 항정신병약물 감량에 관한 연구)

  • Hwang, Tae-Yeon;Lee, Min Soo;Kim, Hyeong-Seob
    • Korean Journal of Biological Psychiatry
    • /
    • v.5 no.2
    • /
    • pp.263-277
    • /
    • 1998
  • Conventional high-dose antipsychotics tend to result in more side effects, negative symptoms and dysphoria, and at the same time lower the cognitive function which is already impaired in most schizophrenics. Florid psychotic symptoms, negative symptoms and cognitive impairment greatly impede psychosocial performance and eventual reintegration into society. The reduction of symptom and the improvement of cognitive funtions and social skills are therefore central to the psychiatric rehabilitation process. The purpose of this study was to evaluate the dose-reduction effects of antipsychotics on chronic schizophrenics prescribed conventional high-dose antipsychotics more than 1,500mg equivalent of chlorpromazine. Fifty-one chronic schizophrenics who maintained high-dose antipsychotics for more than three months were randomly assigned to two groups : 20 patients comprised the dose-maintaining group and 31 patients made the dose-reduction group. Over a sixteen weekperiod Positive and Negative Syndrome Scale(PANSS), Extrapyramidal Symptom(EPS), Nurses' Observation Scale for Inpatient Evaluation(NOSIE-30), Continuous Performance Test(CPT), Quality of Life(QOL), and haloperidol/reduced haloperidol blood levels were determined at the base line and after 2, 4, 6, 8, 12, 16 weeks to evaluate the dose reduction effects of high-dose antipsychotics. The results were as follows : 1) Dose-reduction is highly effective in reducing positive and negative symptoms, and general psychopathology. Effects were most prominent at 8, 12, 16 weeks. Among the dose reduction group, positive symptoms in positive symptom group and negative symptoms in negative symptom group were more reduced. 2 Extrapyramidal symptoms showed no significant difference between two groups. But the EPS was reduced time after time within two groups. 3) Hit rates of Continuous Performance Test, which indicate attentional capacity, increased significantly after dose reduction. 4) Haloperidol and reduced haloperidol blood levels decreased until the 4th week, after which they were constant. 5) Total scores of Nurses' Observation Scale for Inpatient Evaluation were unchanged between the two groups. But among the indices, social interest and personal neatness were improved in the dose-reduction group and retardation was aggrevated in the dose-maintaining group. 6) Total quality of life scores were unchanged between two groups. But in the dose maintaining group, satisfaction scores of attention, autonomy, and interpersonal relationship decreased progressively. These findings suggest that the dose reduction of antipsychotics for chronic schizophrenics on programs of high-dose antipsychotics were effective. Dose reduction should therefore be implemanted to spread the rehabilitation and improve quality of life for chronic schizophrenics.

  • PDF

Development of PC-based Radiation Therapy Planning System

  • Suh, Tae-Suk;P task group, R-T
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.121-122
    • /
    • 2002
  • The main principle of radiation therapy is to deliver optimum dose to tumor to increase tumor cure probability while minimizing dose to critical normal structure to reduce complications. RTP system is required for proper dose plan in radiation therapy treatment. The main goal of this research is to develop dose model for photon, electron, and brachytherapy, and to display dose distribution on patient images with optimum process. The main items developed in this research includes: (l) user requirements and quality control; analysis of user requirement in RTP, networking between RTP and relevant equipment, quality control using phantom for clinical application (2) dose model in RTP; photon, electron, brachytherapy, modifying dose model (3) image processing and 3D visualization; 2D image processing, auto contouring, image reconstruction, 3D visualization (4) object modeling and graphic user interface; development of total software structure, step-by-step planning procedure, window design and user-interface. Our final product show strong capability for routine and advance RTP planning.

  • PDF

Influence of Intravenous Contrast Medium on Dose Calculation Using CT in Treatment Planning for Oesophageal Cancer

  • Li, Hong-Sheng;Chen, Jin-Hu;Zhang, Wei;Shang, Dong-Ping;Li, Bao-Sheng;Sun, Tao;Lin, Xiu-Tong;Yin, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1609-1614
    • /
    • 2013
  • Objective: To evaluate the effect of intravenous contrast on dose calculation in radiation treatment planning for oesophageal cancer. Methods: A total of 22 intravein-contrasted patients with oesophageal cancer were included. The Hounsfield unit (HU) value of the enhanced blood stream in thoracic great vessels and heart was overridden with 45 HU to simulate the non-contrast CT image, and 145 HU, 245 HU, 345 HU, and 445 HU to model the different contrast-enhanced scenarios. 1000 HU and -1000 HU were used to evaluate two non-physiologic extreme scenarios. Variation in dose distribution of the different scenarios was calculated to quantify the effect of contrast enhancement. Results: In the contrast-enhanced scenarios, the mean variation in dose for planning target volume (PTV) was less than 1.0%, and those for the total lung and spinal cord were less than 0.5%. When the HU value of the blood stream exceeded 245 the average variation exceeded 1.0% for the heart V40. In the non-physiologic extreme scenarios, the dose variation of PTV was less than 1.0%, while the dose calculations of the organs at risk were greater than 2.0%. Conclusions: The use of contrast agent does not significantly influence dose calculation of PTV, lung and spinal cord. However, it does have influence on dose accuracy for heart.

The Ameliorative Effect of Angelica acutiloba Ameliorates Through the NO / iNOS Pathway in Rats with Systemic Allergy

  • Cho, Min-Seok;Park, Hae-Woong;Lee, Gil-Hyun;Yoon, Hae-Gyung;Oh, Kyung-Mo;Choi, Seok-Cheol;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.25 no.1
    • /
    • pp.83-91
    • /
    • 2019
  • This study was undertaken to investigate the therapeutic effect of Angelica acutiloba on allergic dermatitis, which Angelica acutiloba is traditionally known to have antiinflammatory effects. Sprague-Dawley (SD) rats were divided into five groups: normal control group, experimental allergic dermatitis group (vehicle group), low dose of Angelica acutiloba extract (low-dose group), high dose of Angelica acutiloba extract (high-dose group), and antihistamine treated group with experimental dermatitis (antihistamine group). Total leukocyte, neutrophil, lymphocyte, monocyte and eosinophil counts were significantly higher in the vehicle group than in the control group, but these variables were significantly lower in the low- and high-dose groups than in the vehicle group. The platelet/lymphocyte ratio in the red blood cell index was significantly lower in the low- and high-dose groups than in the vehicle group. Low and high doses of the Angelica acutiloba extract did not have toxic effects on liver and kidney. Serum NO, iNOS and levels were highest in the vehicle group but significantly lower in the low- and high-dose groups, especially in the high-dose group. The results of this study suggested that the Angelica acutiloba extract had the effect of alleviating or treating the experimental allergic dermatitis, and it was concluded that the high dose was more effective.

The Physiological Activities of Kyung Ok-Ko(II) -Effects on the Hyperglycemia, Hypertension, Anti-Fatigue and Decrease of Body Weight- (경옥고의 생리활성 (II) -고혈당, 고혈압, 지구력 및 체중감소에 미치는 영향-)

  • Whang, Wan-Kyunn;Oh, In-Se;Lee, Suk-Hee;Choi, Soo-Bu;Kim, Il-Hyuk
    • Korean Journal of Pharmacognosy
    • /
    • v.25 no.1
    • /
    • pp.51-58
    • /
    • 1994
  • The studies were conducted to investigate the anti-diabetic activities on the hyperglycemia induced by streptozotocin in rats, anti-hypertensive activities in SHR, anti-fatigue and decrease of body weight activities in mice by Kyung Ok-Ko water extract and drink, which is a traditional preparation in Korea. 1. The blood glucose levels of streptozotocin-induced hyperglycemic rats were dose-dependently decreased by administrations of various doses(300, 600, 1200 mg/kg) of Kyung Ok-Ko water extract. Particularly, administration of 600, 1200 mg/kg were significantly shown to decrease glucose levels comparing with control group. 2. The serum total cholesterol levels of streptozotocin-induced hyperglycemic rats were dose-dependently decreased by administrations of various doses(300, 600, 1200 mg/kg) of Kyung Ok-Ko water extract. Particularly, administration of 600, 1200 mg/kg were significantly shown to decrease total cholesterol levels comparing with control group. 3. The serum triglyceride levels of streptozotocin-induced hyperglycemic rats were dose-dependently decreased by administrations of various doses(300, 600, 1200 mg/kg) of Kyung Ok-Ko water extract. Particularly, administration of 600, 1200 mg/kg were significantly shown to decrease triglyceride levels comparing with control group. 4. The blood pressure in SHRs were dose-dependently lower descended by administration of Kyung Ok-Ko water extract 300, 600, and 1200 mg/kg, respectively. 5. The swimming time of Kyung Ok-Ko water extract(100, 200, 400 mg/kg) and drink(0.7, 1.4, 2.1 ml/kg) were significantly extended to all experimental group dose-dependantly. 6. The decrease of body weight of Kyung Ok-Ko water extract(100, 200, 400 mg/kg) and drink(0.7, 1.4, 2.1 ml/kg) were significantly evaluated dose-dependently in all experimental group.

  • PDF

Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation (전신방사선조사(Total Body Irradiation) 시 Beam Spoiler와 환자 간의 거리에 관한 고찰)

  • Choi, Jong-Hwan;Kim, Jong-Sik;Choi, Ji-Min;Shin, Eun-Hyuk;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.51-54
    • /
    • 2007
  • Purpose: Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Materials and Methods: Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = $40{\times}40cm^2$. The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Results: Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is $14.58{\sim}14.92cGy$. Therefore, The surface dose was measured $99.4{\sim}101%$ with got near most to the prescription dose. Conclusion: In clinical case, distance between beam spoiler and patient affect surface dose. If once $50{\sim}60cm$ of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  • PDF

Artificial Insemination with Low-Dose Semen does not affect Swine Reproductive Performances

  • Chung, Ki-Hwa;Lee, Il-Joo;Sa, Soo-Jin;Kim, In-Cheul;Jung, Byeong-Yeal;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.37 no.4
    • /
    • pp.263-267
    • /
    • 2013
  • Pig producers have been shown keen interest of the number of spermatozoa in a semen dose since pig artificial insemination introduce. However, determining the minimal number of spermatozoa need per AI without detrimental effect on overall reproductive performances is not an easy question to answer. To increase the efficiency of semen utilization in pig AI, optimum number of spermatozoa per dose needed to determine. The objective of this study was to determine the reproductive performance and factors that affect on-farm application of low-dose semen insemination in sows. Data were collected from Darby Genetics AI studs from 4th of June to 7th of July, 2012 (n=401). The numbers of parturition were 84, 234 and 83 in sows inseminated with doses of $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ spermatozoa in 100ml extender, respectively. There were no significant differences on reproductive performances such as gestation period, total born, total born alive, stillbirth and mummy in sows inseminated with different semen doses. The average number of born alive was 10.5, 11.0 and 10.4 from sows inseminated with $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ sperms, respectively. Also, number of spermatozoa per dose did not affect litter size (p>0.10). There were no significant differences of maternal genetic line difference on gestation period, total number born, number born alive, born dead and mummy. The estimated correlation coefficients of the different semen doses with total number born, number born alive, born dead and mummy were r=-0.00, -0.01, 0.02 and 0.02, respectively. Taken together, the result of this study suggested that when semen was appropriately inseminated after induced ovulation, insemination with low-dose ($1.5{\sim}2.0{\times}10^9$) semen dose not adversely affect sow's fertility.