• 제목/요약/키워드: total coliform

검색결과 604건 처리시간 0.029초

유치원 급식으로 이용되는 알팔파 새싹채소의 소독방법에 따른 미생물제어 효과 (Effect of Microbial Control on Alfalfa Sprout Vegetable by Depending on Sanitization Method in Kindergarten Foodservice)

  • 우수희
    • 대한통합의학회지
    • /
    • 제4권4호
    • /
    • pp.109-117
    • /
    • 2016
  • Purpose : This study was designed to provide basic data of effective sanitization method of sprout vegetable for microbiological safety. Methods : Sanitization treatments were performed by dipping the sprout into chlorine and vinegar water. Microbial analysis were composed of the total plate count(TPC) and coliform group count(CGC). Result : Among chlorine water sanitization, the microbial reduction was largest in 100ppm chlorine water, and its TPC and coliform group count decreased to 6.01 log CFU/g and 5.06 log CFU/g. The effective dipping time in 100ppm chlorine water treatment was 5.97 log CFU/g and 5.91 log CFU/g for 30min and 60min, in which TPC were below the microbiological safety limits of 6.00 log CFU/g. Coliform group counts were decreased to 5.44, 5.46, 5.42 log CFU/g in the dipping the spouts for 30min, 60min and 90min. As a result of sanitizing alfalfa spout by vinegar water, a microbial counts tended to decrease with increasing concentration and the dipping time. The effective concentration of vinegar water was 2% for TPC(6.00 log CFU/g) and 1% for coliform group count(5.20 log CFU/g). With 1% vinegar water treatment, TPC became below the microbiological safety limits in all samples and in particular, the sample treated for 60min and 90min(4.93, 4.54 log CFU/g). While coliform group counts were decreased to 3.91 log CFU/g in the dipping the sprouts for 90min, those were still beyond the permitted limit. Conclusion : To secure the food safety of food service facilities including kindergarten feeding, it is considered that along with the systematic study of effective disinfection method for microbiological control at the preconditioning level of spout vegetable within the range of secured maleficence to human body, and the study regarding the measures to lower the initial microbiological pollution of spout vegetable.

서울시내 옹달샘물의 지표미생물 분포현황 (Distribution of Indicator bacteria in Spring Water in Seoul)

  • 류승희;박석기
    • 한국식품위생안전성학회지
    • /
    • 제17권2호
    • /
    • pp.55-60
    • /
    • 2002
  • In order to investigate the microbiological contamination of spring water, we performed the standard plate count, coliform and psychrotrophilic bacteria in 109 spring waters in Seoul. Of 109 spring waters, geometirc mean standard plate count was 0.19 CFU/ml, and the highest in Mt. Boolam, 4..43 CFU/ml and Mt. Dobong, 3.86 CFU/ml, but not detected in Mt. Woomyun and Mt. Cheonggye. Four spring waters have shown over 100 CFU/ml in standard plate count. The geometric mean psychrotrophilic bacteria was 49.2 CFU/ml, the most prevalent spring water was Mt. Nam, 125 CFU/ml, the lowest Mt. Woomyeun. Among a total of 109, coliform was detected from 21 spring waters(19.3%) and the geometric mean of coliform was 0.005 MPN/100ml. The isolated genera of coliform were 7 isolates of E. coli(33%), 5 Klebsiella(24%), 4 Enterobacter(19%), 3 Citrobacter(14%) and 2 Serratia(10%), respectively. The 22 spring waters(20.2%) failed to meet the standard limits of drinking water based on regulation in Korea. The inappropriate rate of standard plate count in spring water was 4.5%, that of coliform was 81.1% and both of them was 13.6%. There was the significant correlation between standard plate count and psychrotrophilic bacteria in spring water(r=0.95, p<0.01).

통영항의 해수 및 저질의 위생학적 특성 (Sanitary Characteristics of Seawater and Sediments in Tongyeong Harbor)

  • 박준용;김영인;배기성;오광수;최종덕
    • 한국식품위생안전성학회지
    • /
    • 제25권4호
    • /
    • pp.367-375
    • /
    • 2010
  • 이 연구는 통영항 내의 해수와 저질의 특성과 주변횟집의 수질의 품질 특성에 대하여 2008년 6월부터 2009년 5월까지 월 1회 조사를 실시하였으며 그 결과는 다음과 같다. 통영항의 해양수온은 평균 $17.4{\pm}5.77^{\circ}C$, 투명도 평균 $1.9{\pm}0.46$ m, 부유물질 $36.7{\pm}5.00$ mg/L, COD $2.36{\pm}0.80$ mg/L, DO $6.67{\pm}1.54$ mg/L, 염분농도 $32.3{\pm}0.64$‰를 각각 나타내었다. 아질산 질소는 $0.010{\pm}0.005$ mg/L, 질산 질소 $0.050{\pm}0.011$ mg/L, 암모니아 질소 $0.030{\pm}0.007$ mg/L, 인산 인 $0.050{\pm}0.006$ mg/L로 각각 나타났으며, TBT는 검출한계 이하로 검출되었다. 통영항 해수 중의 total coliform은 조사기간 중 < 1.8~22,000 MPN/100 mL 범위에 기하학적 평균값이 164.9 MPN/100 mL이었고 230 MPN/l00 mL을 초과하는 비율은 39.6%를 나타내었다. fecal coliform은 < 1.8~7,900 MPN/100 mL 범위에 기하학적평균값은 33.7 MPN/100 mL, 43 MPN/100 mL을 초과하는 비율은 47.9%로 조사되었다. total coliform에 대한 fecal coliform 검출 비율은 69.2%로 나타났다. 통영항 해수 중의 비브리오는 6월부터 11월에 240주가 검출되었으며, V. alginolyticus가 82주로 34.2%를 차지하여 가장 많이 검출되었고, 그 밖에 parahaemolyticus가 13.8%, V. culnificus 10.0%, V. cholerae non-O1이 0%, V. mimicus 12.5%가 검출되었다. 저질 특성은 함수율이 $56.63{\pm}5.51$ %, 강열감량 $9.20{\pm}1.36$%, COD $7.64{\pm}1.13$ mg/g, AVS $0.07{\pm}0.02$mg/g으로 다른 해역에 비하여 다소 높게 나타났다. 중금속의 함량은 카드뮴(Cd)은 $0.10{\pm}0.05$, 구리(Cu) $4.79{\pm}8.20$, 비소(As) $1.95{\pm}0.17$, 수은(Hg) $0.10{\pm}0.07$, 납은 불검출, 6가크롬은 ($Cr^{6+}$) $0.34{\pm}0.12$, 아연 (Zn) $125.33{\pm}16.40$, 니켈(Ni) $16.34{\pm}1.93$ mg/kg을 나타내었다. 통영항 주변 횟집의 total coliform 및 fecal coliform은 횟집에 따라서 다소 차이가 있었지만 여름철에 주로 검출되었으며, 여름철 집중관리가 요구되었다.

Evaluation of raw wastewater characteristic and effluent quality in Kashan Wastewater Treatment Plant

  • Dehghani, Rouhullah;Miranzadeh, Mohammad Bagher;Tehrani, Ashraf Mazaheri;Akbari, Hossein;Iranshahi, Leila;Zeraatkar, Abbas
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.273-278
    • /
    • 2018
  • Due to the lack of water in arid and semi-arid areas, reuse of wastewater can be a suitable way to compensate for water scarcity. Therefore, in this research, evaluation of the quality of wastewater of Kashan Treatment Plant to use for irrigation was studied. This descriptive cross-sectional study was conducted in 2016. pH, TSS, TDS, turbidity, COD, BOD5, Total Kjeldahl Nitrogen, Total Phosphorus, Total Coliform, fecal coliform, nematode eggs of inlet and outlet of wastewater treatment plant in Kashan were studied. Mean and standard deviation and wastewater quality parameters before and after treatment were tested with SPSS 22 (2014) software. The mean wastewater output of COD, BOD5, TSS, TDS and turbidity were respectively 86.6, 41.2, 11.11, 1095 mgL-1 and 17.5 NTU and the pH was equal to 7.22. Also, the average of Total Kjeldahl Nitrogen and phosphorus were 22.4 and 2.2 mgL-1 respectively. The mean of Total Coliform and fecal coliform were 225, 161 MPN / 100 ml respectively. In addition, no nematode eggs were found in final effluent. The results indicated that the treatment plants had a significant role in the control of microbial and organic pollution load of wastewater. Also, it is concluded that all parameters were in accordance with the standards of Iran's Department of Environment, so, it can be used for unrestricted irrigation.

대구신천(大邱新川)으로부터 분리(分離)된 약제내성대장균군(藥劑耐性大腸菌群)의 전달성내성(傳達性耐性)에 관(關)하여 (Drug Resistant Coliform Organisms in Shinchun Stream (Daegu))

  • 김기석;탁련빈
    • 대한수의학회지
    • /
    • 제17권2호
    • /
    • pp.73-78
    • /
    • 1977
  • The distribution of coliform population and drug-resistant coliforms in Shinchun water during April to August in 1976 and R factors in resistant strains were studied. The mean coliform population in the stream water was 361 organisms per 0.1ml and 53.5% of total coliforms were fecal coliforms. Thritynine and a half percent of total coliforms were streptomycin (SM) resistant to one or more of following antibiotics; tetracycline (TC), chloramphenicol (CM), ampicillin (AP) and kanamycin (KM). The most frequent resistant pattern was triple resistance to SM, TC and AP (23.8%) and followed by quadruple one to SM, TC, CM and AP (17.5%). About 87 percent strains carried R factors which were transferable by conjugation to E. coli ML 1410 or S. typhimurium LT 2.

  • PDF

낙동상 하류 수역의 Microflora (Microflora of the Lower Part of the Nagdong River)

  • 김용관;이태식;신일식
    • 한국환경보건학회지
    • /
    • 제16권2호
    • /
    • pp.47-53
    • /
    • 1990
  • This experiment was carried out to evaluate general characteristics of the water quality, total coliform, fecal coliform and microflora at the St. 1 to St. 3 and St. 4 to St. 7. Eighty-four water samples were collected from the 7 stations from July 1988 to April 1990 (see Fig. 1) Range and mean value of the samples were as follows water temperature 2.0-29.9$^{\circ}$C, 16.3$^{\circ}$C pH 6.86-9.08, 7.62: electrical conductivity 54.85$\mu \mho$/cm, 4.300 m$\mho$/cm, 911.93 $\mu \mho$/cm : turbidity 0.9-36 NTU, 6.8 NTU, respectively. pH and electrical conductivity at St. 4 to St. 7 were higher than those at St. 1 to St. 3, but turbidity at St. 1 to St. 2 was 7 times higher than that at Sonagdong river area. The bacterial density of the samples ranged 91-110,000/100ml for total coliform. 21-15,000/100ml for fecal coliform. Specially, the geometric mean value of the St. 3 was 11,836 / 100ml for it leveled heavy contaminaiton. Predominant species among the 3,874 strains isolated form the samples were 30.6% Enterobacteriaceae, 14.7% Acinetobacter, 9.0% Aeromonas. 8.9% Neisseria, and 7.5% Vibrio.

  • PDF

수돗물에서의 대장균군 재생장과 손상 대장균군 (Coliform Regrowth and Injured Coliforms in Public Water Supply)

  • 박성주;조재창;김상종
    • 환경위생공학
    • /
    • 제9권2호
    • /
    • pp.50-57
    • /
    • 1994
  • Densities of total and injured coliforms in treated water( TW ) and three tap water salt pies( Taps Kl, K2 and K3) of Ku- eui water treatment plant and one tap water sample( Tap T) of Tuk- do water treatment plant were measured 23 times from 1991 to 1992. Coliform regrowth in the water distribution system occurred three times during the study period. When the regrowth episode occurred, injured coliforms were always but total coliforms were not always detected in treated water. Mean densities of total coliforms in TW, and Taps Kl, K2, K3 and T were 0.8, 2.3, 1.9, 1.4 and 2.1 cfu/100mℓ by membrane filtration method using m- TF agar and those of injured coliforms were 3.4, 2.8, 2.5, 2.7 and 2.9 c1u/100mℓ using mondo- LES agar. The injury rates of TW and Taps Kl, K2, K3 and T were 89.5,77.4,67.9, 82.8 and 75.9%, respectively. The high injury rate of coliform bacteria in Seoul water supply can cause regrowth problems in distribution systems due to the repair of injured cells under an appropriate condition. It is recommended the injured coliforms should be measured in drinking water since they can lead to a significant underestimation of total coliforms and result in an inaccurate evaluation of the potential health risks.

  • PDF

겨울철에 시판되는 어패류에 있어서의 E. coli와 Coliform에 관한 연구 -서울시 가락동 농수산물시장을 중심으로- (A Study on Contamination of Fish Sold at Wholesale Market in Seoul Area -Material Collected from Seoul Karak Fish Market-)

  • 노병의;빈성오;김성원
    • 한국식품위생안전성학회지
    • /
    • 제12권4호
    • /
    • pp.294-299
    • /
    • 1997
  • A study was conducted to determine contamination status of fish sold at wholesale market in Seoul. A total of 79 samples (35 different kindry fish) were collected from the wholesale market. E. coli and coliform group bacteria were cultured and tested for sensitivity against antibiotics. The results are summarized as follows; 1. E. coli was isolated from 23 out of 79 samples (29.1%), and coliform groups from 53 out of 79 (67.1%). 2. Of coliform group, Citrobacter freundii was the most common and Enterobacter clacae was the next. 3.23 E. coli strains isolated from fishes were resistant to Oxacillin, Erythromycin and Lincomycin, meanwhile 23 E. coli strains were sensitive to Cefoperazone, Ceftazidime, Imipenem, and Ciprofloxacin.

  • PDF

합류식 하수관거 월류수의 지표미생물 배출 특성 (Discharge Characteristics of the Indicator Microorganisms of Combined Sewer Overflows)

  • 김건하
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.627-635
    • /
    • 2006
  • Combined sewer overflow (CSOs) is a primary diffuse source degrading water quality of urban streams. In this study, CSOs caused by 5 different rainfall events at an urban watershed located in Daejeon city were monitored for the indicator microorganism concentrations. Event mean concentration (EMC) of the indicator microorganisms were: total coliform = $2.46{\times}10^6CFU/100mL$; fecal coliform = $1.01{\times}10^6CFU/100mL$; E.coli = $5.20{\times}10^5CFU/100mL$; and Fecal Streptococci = $6.08{\times}10^5CFU/100mL$. In addition, coliform concentrations were well correlated with suspended solid concentrations and the first flush effects were identified. Settling tests were carried out to estimate removal rate of indicator organisms by sedimentation from CSOs. As microorganisms are discharged in association with suspended solid, ten minutes of settlement can lower 44% of indicator microorganism leading.

도시하수 처리에 의한 미생물 오염의 제거효과에 관한 조사연구(I) -청계천 하수처리장을 중심으로- (An Analysis on Removal Effect of Biological Contaminants in the Process of Municipal Sewage Treatment System - On the Seoul Cheonggye Cheon Sewage Treatment Plant)

  • 유병태;정용
    • 환경위생공학
    • /
    • 제3권1호
    • /
    • pp.27-39
    • /
    • 1988
  • This investigation was carried out to evaluate the removal effect of biological contaminants for the municipal sewage treatment process at Cheonggye Cheon terminal plant which in the first plant for municipal sewage treatment in Seoul area. It was conducted in raw influent, primary treatment water and secondary treatment water from September, 1986 to July, 1987. The results were as follow; 1, The primary treatment could eliminate microbials for $65.38\%$ of total bacteria, $64.35\%$ of total coliform, $62.16\%$ of fecal coliform $69.48\%$ of pseudomonas and $64.70\%$ of fecal streptococci in averages for a year respectively. 2. The secondary treatment could eliminate microbials for $97.50\%$ of total bacteria, $97.30\%$of total coliform, $95.95\%$ of fecal coliform, $97.00\%$ of pseudomonas and $96.53\%$ of fecal streptococci in average for a year respectively. 3. In the detect rate of pathogenic agent, salmonella spp was decreased $12.5\%$ to $4.2\%$ in primary treatment and it was not detected in secondary treatment, shigella spp was detected $4.2\%$ in influent water but it was not detected in primary and secondary treatment. 4. In the seasonal variation of treatment effect, the removal of summer was the highest, and the removal of all item in winter was lower than the other seasons. 5. There was significant correlation between water temperature and microbal all items (P<0.05) $NH_3-N$ and Microbal items (P< 0.01) at raw water.

  • PDF