• Title/Summary/Keyword: top and seat angle connections

Search Result 15, Processing Time 0.021 seconds

An Experimental Study on Steel Plate Coupling Beam (철골 플레이트 커플링 보의 실험적 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presented an structural efficiency of steel coupling beam jointed single plate shear connections with seat and top angle. Parameters for the test specimens were are seat and top angle, reinforcing of concrete, embedded length, section loss. Steel coupling beam with angle showed excellent strength, stiffness, energy dissipation capacity. The specimen with no reinforcement around the embedded steel plate showed slightly low deformation capacity because of early failure in the precast concrete walls. However, the specimen with reinforcement around the embedded steel plate showed good deformation capacity. Deformation capacity was not decrease despite short embedded length. The specimen with section loss showed excellent deformation capacity. Because shear strength of steel coupling beam was lesser than of connections. These results showed that for workability and cost efficiency, the proposed system is promising for one of steel coupling beam.

  • PDF

Cyclic behavior of steel beam-to-column connections with novel strengthened angle components

  • Kang, Lan;Zhang, Cheng
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.791-804
    • /
    • 2022
  • As a type of semi-rigid connection, the top and seat angle connections are popular in current structures owing to their good cyclic performance and simple erection. However, their stiffness and load bearing capacity are relatively insufficient. This study proposes two strengthening methods to further increase the stiffness and strength of bolted-angle joints while maintaining satisfactory energy dissipation capacity (EDC) and ductility. Cyclic loading tests were conducted on six joint specimens with different strengthened angle components. Based on the test results, the influence of the following important factors on the cyclic behavior of steel joint specimens was investigated: the position of the rib stiffeners (edge rib stiffeners and middle rib stiffener), steel strength grade of rib stiffeners (Q345 and Q690), and additional stiffeners or not. In addition, the finite element models of these specimens were built and validated through a comparison of experimental and numerical results. The stiffness and bearing capacity of the bolted-angle joints could be improved significantly by utilizing the novel strengthened joints proposed in this study. Moreover, this can be achieved with almost no increase in the amount of steel required, and the EDC of this joint could also satisfy the requirements of seismic codes from various countries.

The Weld Strength and Design Tables for the Unstiffened Seated Connections (비보강받침접합의 용접강도와 설계도표)

  • Choi, Sun-Kyu;Yoo, Jung-Han;Lee, Kang-Min;Park, Jai-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.199-206
    • /
    • 2012
  • Unstiffened seated connections (USC) ensure easy installation and safety during erection, thereby making the process more economical. USCs consist of a seat angle for carrying the beam's reactions and a top angle to provide beam stability. These angles are bolted or welded to the beam and supporting member. This paper sought to propose a design table for the weld strength of such connections obtained from the elastic vector method (EVM) and the instantaneous center-of-rotation method (ICM) in terms of calculating the eccentricity. Also, the proposed design table is compared with both AISC and KBC specifications.

Second Order Elastic Analysis of Superstructures on Very Large Floating Structure with Semi-Rigid Connections (반강접 접합부를 적용한 초대형 부유식 구조물 상부구조체의 2차 탄성해석)

  • Song, Hwa-Cheol;Lee, Eun-Suk
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • If semi-rigid connections are used for superstructures of very large floating structures (VLFS), the number of rigid connections can be reduced and more economical construction will be possible. In this study, considering service load and wave load in VLFS, the applicability of mixed use of rigid and semi-rigid connections have been studied using three types of connections for a four-bay eight-story frame. Three types of connections are used; top and seat-angle connections with double web-angle(TSD), extended end plate connections, steel tubular column with square external-diaphragm connections. ABAQUS(Finite element analysis program) is used for conducting second order elastic analysis.

Experimental study on replaceable precast concrete beam-column connections

  • Seung-Ho Choi;Sang-Hoon Lee;Jae-Hyun Kim;Inwook Heo;Hoseong Jeong;Kang Su Kim
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2024
  • The purpose of this study was to develop a system capable of restoring the seismic performance of a precast concrete (PC) connection damaged by an earthquake. The developed PC connection consists of a top-and-seat angle, post-tensioning (PT) tendons, and U-shaped steel. The PC beam can be replaced by cutting the PT tendons in the event of damage. In addition, the seismic performance of the developed PC beam-column connection was evaluated experimentally. A PC beam-column connection specimen was fabricated, and a quasistatic cyclic loading test was conducted to a maximum drift ratio of 2.3%. Subsequently, the PC beam was replaced by a new PC beam, and the repaired PC connection was loaded to a maximum drift ratio of 5.1%. The structural performance of the repaired PC connection was then compared with that of the original PC connection. The difference in the load at the drift ratio of 2.3% between the original and the repaired PC specimens was only 0.2%. The residual drift ratio in the repaired PC specimen did not exceed 1.0% at the 2.0 % drift ratio cycles, which satisfies the life safety performance level specified in ACI 374.2R-13. When the developed PC connection system is used, structural performance can be restored by rapidly replacing the damaged elements.