• Title/Summary/Keyword: tool position

Search Result 914, Processing Time 0.03 seconds

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Empirical Study for the Appraisal System of Execution Capacity using Correlation Analysis (상관관계분석을 이용한 시공능력평가 제도의 실증적 고찰)

  • Jeong, Keun Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.2
    • /
    • pp.3-14
    • /
    • 2018
  • The system to appraise the execution capabilities of construction companies had been began as the Construction Contract Restriction System in 1958, was changed as the Construction Subcontract Restriction System in 1961, and finally has been operated as the Appraisal and Public Announcement of Execution Capacity (APAEC) from 1996. The APAEC system has been utilized as a firm and unique tool for assessing the execution capacities of construction companies despite many problems and continuous system changes. In spite of numerous studies to improve the APAEC system, however, efforts to analyze the system from the empirical point of view were insufficient. In this study, we analyze the status of APAEC system through analyzing correlations among assessment results of the APAEC, earned values of construction works, construction management performance indexes, and macroeconomic indexes for the past 10 years from 2007 to 2016. As a result of the analysis, it was found that Appraisal Value of Execution Capacity (AVEC) is excessively inflated in engineering and landscaping areas compared to Earned Value of Construction Work (EVCW) and the correlations between the AVECs and EVECs are not high in the areas of engineering, industrial equipment, and landscaping. In addition, technical appraisal values are excessively inflated in engineering and landscaping areas and correlations between AVEC and its components are high in the areas of engineering & building, industrial equipment, and large companies, but low in the areas of engineering, building, landscaping, and small and medium companies. Finally, the concentration of the AVEC is intensifying more and more and the concentration deteriorates construction management performance indexes and macroeconomic indexes. If we continuously improve the APAEC system based on the implications derived in this study, the APAEC system will be able to maintain it's position of a firm and unique means to access the execution capacities of construction companies.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Rapid Analysis of Nitrate Concentration in Different Growth Stages and Plant Parts of Paprika Leaf Using On-site Rapid Detection Kit (신속분석기기를 이용한 파프리카 생육단계 및 부위별 엽내 질산태질소 농도 신속분석)

  • Lee, Min Ji;Rhee, Han Cheol;Choi, Gyeong Lee;Oh, Sang Seok;Lee, Jae Taek;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.333-339
    • /
    • 2017
  • This research was aimed to establish rapid analysis technique for the determination of nitrate ($NO_3{^-}$) concentration in the leaves of paprika, which has key role for the stable vegetative and reproductive growth. Leaf petiole and blade sap of two paprika cultivars ('Raon red' and 'Raon yellow') were used for the determination of $NO_3{^-}$ concentration, separately using rapid detection kit (RQ-flex) and spectroscopy quantification methods. In addition, two paprika cultivars namely, 'Nicole' and 'TP2001' were used to determine the status of $NO_3{^-}$ concentration in leaf of each fruiting group. $NO_3{^-}$ concentration in leaf blade sap and the content in leaf showed significant correlation ($R^2=0.8628$), analysed by RQ-flex and spectroscopy methods, respectively. Furthermore, leaf petiole sap and the content in leaf also showed significant correlation ($R^2=0.6734$) but the relationship was poor compared to leaf blade sap and the leaf content. $NO_3{^-}$ concentration in petiole sap decreased in all the cultivars from early to late fruiting group. The higher concentration in the lower leaves and the continuous decrease towards the upper leaves in the both years were found through the analysis of $NO_3{^-}$ concentration in different leaf position. In addition, daily short-term fluctuation of $NO_3{^-}$ in petiole sap could be rapidly monitored. These results showed that long-term or short-term monitoring by test strip-based rapid analysis technique might be useful tool for the diagnosis of nutritional status for the stable of nutritional management in paprika.

The application of photographs resources for constructive social studies (구성주의적 사회과 교육을 위한 사진자료 활용방안)

  • Lee, Ki-Bok;Hwang, Hong-Seop
    • Journal of the Korean association of regional geographers
    • /
    • v.6 no.3
    • /
    • pp.117-138
    • /
    • 2000
  • This study is, from the view point of constructive social studies which is the foundation of the 7th curriculum, to explore whether there is any viable program and to investigate it by which students, using photo resources in social studies, can organize their knowledge in the way of self-directed thinking. The main results are as follows: If it is a principle of knowledge construction process of constructive social studies that individual construction (cognitive construction) develops into communal construction(social construction) and yet communal construction develops itself, interacting with individual construction, it will be meet the objectives of social studies. In social studies, photos are a powerful communication tool. communicating with photos enables to invoke not only the visual aspects but also invisible aspects of social phenomena from photos. It, therefore, can help develop thinking power through inquiry learning, which is one of the emphasis of the 7th curriculum. Having analyzed photo resources appeared on the regional textbooks in elementary social studies, they have been appeared that even though the importance and amount of space photo resources occupy per page is big with regard to total resources, most of the photos failed to lad to self-directed thinking but just assistant material in stead. Besides, there appeared some problems with the title, variety, size, position, tone of color, visibility of the photos, and further with the combination of the photos. Developing of photo resources for constructive social studies is to overcome some problems inherent in current text books and to reflect the theoretical background of the 7th curriculum. To develop the sort of photo that can realize the point just mentioned, it would be highly preferable to provide photo database to facilitate study with homepage through web-based interaction. To take advantage of constructive photo resources, the instruction is strategized in four stages, intuition, conflict, accommodation, and equilibration stage. With the advancement of the era of image culture, curriculum developers are required to develop dynamic, multidimensional digital photos rather than static photos when develop text books.

  • PDF

Use of Human Serum Albumin Fusion Tags for Recombinant Protein Secretory Expression in the Methylotrophic Yeast Hansenula polymorpha (메탄올 자화효모 Hansenula polymorpha에서의 재조합 단백질 분비발현을 위한 인체 혈청 알부민 융합단편의 활용)

  • Song, Ji-Hye;Hwang, Dong Hyeon;Oh, Doo-Byoung;Rhee, Sang Ki;Kwon, Ohsuk
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.1
    • /
    • pp.17-25
    • /
    • 2013
  • The thermotolerant methylotrophic yeast Hansenula polymorpha is an attractive model organism for various fundamental studies, such as the genetic control of enzymes involved in methanol metabolism, peroxisome biogenesis, nitrate assimilation, and resistance to heavy metals and oxidative stresses. In addition, H. polymorpha has been highlighted as a promising recombinant protein expression host, especially due to the availability of strong and tightly regulatable promoters. In this study, we investigated the possibility of employing human serum albumin (HSA) as the fusion tag for the secretory expression of heterologous proteins in H. polymorpha. A set of four expression cassettes, which contained the methanol oxidase (MOX) promoter, translational HSA fusion tag, and the terminator of MOX, were constructed. The expression cassettes were also designed to contain sequences for accessory elements including His8-tag, $2{\times}(Gly_4Ser_1)$ linkers, tobacco etch virus protease recognition sites (Tev), multi-cloning sites, and strep-tags. To determine the effects of the size of the HSA fusion tag on the secretory expression of the target protein, each cassette contained the HSA gene fragment truncated at a specific position based on its domain structure. By using the Green fluorescence protein gene as the reporter, the properties of each expression cassette were compared in various conditions. Our results suggest that the translational HSA fusion tag is an efficient tool for the secretory expression of recombinant proteins in H. polymorpha.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

A Criteria on Nitrate Concentration in Soil Solution and Leaf Petiole Juice for Fertigation of Cucumber (Cucumis sativus L.) under Greenhouse Cultivation (시설 오이의 관비재배를 위한 토양용액과 엽병즙액중 질산태 농도 기준 설정)

  • Lim, Jae-Hyun;Lee, In-Bog;Kim, Hong-Lim
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2001
  • To develope a technique for efficiently managing fertilizer for cucumber, a quick test method to quantify nitrate content in soil solution and leaf petiole juice using a simple instrument was investigated. Among the nitrate analyzing instruments such as compact ion meter, nitrate ion meter, and test strip with reflectometer, the paper test-strip used in conjunction with a hand-held reflectometer was most closely correlated with ion chromatography method in nitrate content, and then it would be suggested with a tool that a farmer can use rapidly, conveniently and accurately for nitrate analysis in a field. Nitrate content in soil solution collected by porous cup was very variable on the lapsed time after drip irrigation and the sampling positions such as soil depth and the distance from dripper. As a result, a significant correlation between nitrate contents of soil solutions and 2M KCl soil extract was not found. However, nitrate content in soil solution extracted with a volume basis (soil:water=1:2) showed the highly significant correlation with that in 2M KCl extract. Nitrate contents of cucumber leaf petiole juices was greatly different between upper and lower leaves. Eleven to sixteen positioned-leaf would be a proper sampling position to determine nitrate content in leaf petiole for evaluating nutrient state by plant tissue analysis. From the secondary regression equations between nitrate contents of soil and petiole juice and the yield of cucumber, nitrate levels for real time diagnosis were estimated as $400mg\;l^{-1}$ soil solution by porous cup. $300mg\;l^{-1}$ in a soil volume extraction, and $1400mg\;l^{-1}$ in petiole juice from spring to summer season. In addition, the maximum yield of cucumber fruit in pot test was obtained in nitrate $1500mg\;l^{-1}$ level of petiole juice, which was similar to nitrate $1400mg\;l^{-1}$ in greenhouse trial.

  • PDF

Tendency of 'a Cartoon Image' Appearing in Korean Modern Fine Arts - Ocusing on 'Atomouse' of Lee Dong-gi - (한국 현대 미술에 나타나는 '만화 이미지'의 경향성 -이동기의 <아토마우스>를 중심으로-)

  • Jeon, Young Je
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.669-702
    • /
    • 2014
  • Today, in Korean modern fine arts, 'cartoon images' are utilized for their roles of the 'personas' of the artists, and as the 'texts' for the artistic discourses, while they play a role as a bridgehead between the public and art. In this study, we made a study, focusing on 'Atomouse' of Lee Dong-gi, in order to examine how the borrowing of the 'cartoon images' was made in the Korean modern fine arts, and what its period context is. 'Atomouse' of Lee Dong-gi is the first cartoon character that appeared in Korean modern fine arts, and it has acquired a symbolism of a subculture being acknowledged as art. In this study, we tried to find out what period contexts the changes of 'Atomouse' have, focusing on the private exhibitions of Lee Dong-gi, such as 'Smoking' Exhibition (2006), 'Bubble' Exhibition (2008), 'Double Vision' Exhibition (2008), 'The Garden of Uncertainty' Exhibition (2012) and 'Do Not Look Back with Angry Face' Exhibition (2013). Atomouse was born in the era of 'lack of pop' a change was attempted of it in the era of 'excess of pop' and its proceeding ended along with the 'settlement of the neo-pop'. From Atomouse started from the unconsciousness of the artist, we can find the 'identity' of the Republic of Korea, which was being influenced by the 'American and Japanese' culture, as well as the symbolism of a subculture being acknowledged as art, while it emerged as an icon to represent the Korean pop art of the time. Then, as the agony and self-examination of the artist was contained in it, its use was changed into the role as a persona and it was utilized as a tool to connect the and figurative worlds. In the end, the artist put an end to the proceeding of the 'Atomouse' at the boundaries of a persona and an alter ego, removing the creation with his own hands. In the process in which Lee Dong-gi created and changed 'Atomouse', the start-up and growth of the pop art are included in the history of the Korean modern fine arts, apart from a study of an artist. 'Atomouse' was not only painted on the walls of the subway stations in the form of public art, but it tried to closely communicate with the public through the collaboration with diverse media. It made the best use of the 'marketability' which a 'cartoon character' had at first, so that pure art was made a step closer to the public. So 'Atomouse' of Lee Dong-gi not only raised a subculture into the realm of high art, but lowered the door sill to high art. Through the study we could confirm what position 'Atomouse' of Lee Dong-gi, which started absurdly between parody and Hommage, takes in Korean modern art of today.

Usefulness of Rotation for Toric Soft Lenses Using Objective Refraction (타각적 굴절검사를 이용한 토릭 소프트 렌즈 회전 평가의 유용성)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2011
  • Purpose: The clinical usefulness of rotation evaluation using objective refraction in toric soft lenses fitting was investigated. Methods: Toric soft lenses were fitted for 32 subjects (64 eyes; mean age of 24.69 ${\pm}$ 1.65 years) with astigmatism and both eyes of each subject were fitted with toric soft lenses. Objective refraction-based lenses rotation was evaluated from refraction and over-refraction data by indirect calculating technique. These calculated data were compared with the measured data from slit lamp with direct measuring technique. Results: Orientation of toric soft lenses around zero position (within ${\pm}$ 5$^{\circ}$ vertical line) was investigated. The orientations to the direction of nose of measured and calculated values were 69.78% and 63.64%, respectively, which showed similar values between two techniques. Agreement frequency between measured and calculated values in the magnitude of lenses rotation 54.69% and 82.82% for 10$^{\circ}$ and 20$^{\circ}$ of vertical line, respectively. The 95% limits of agreement between calculation and measurement were from -10.08$^{\circ}$ to 12.65$^{\circ}$, and mean difference was 1.29$^{\circ}$ within ${\pm}$ 10$^{\circ}$. The result showed there was no significant difference (p = 0.1984) and high correlation (r = 0.56, p = 0.0004) between two techniques. But the 95% limits of agreement was widen in ${\pm}$ 20$^{\circ}$ of vertical line. The magnitude of lens rotation between two methods was 9.66 ${\pm}$ 6.16$^{\circ}$, 16.17 ${\pm}$ 12.38$^{\circ}$ and 10.58 ${\pm}$ 12.02$^{\circ}$ for normal, loose and tight fitted conditions. Conclusions: From the results with smaller difference between two techniques, it was found that higher availability of subjective over-refraction data can be used as a supplementary tool for subjective refraction. An application using objective refraction with direct measuring could be provide high success in prescription on toric soft lenses.