• Title/Summary/Keyword: titanium dental implant

Search Result 320, Processing Time 0.028 seconds

Effect of Titanium Coating on Cell Adhesion and Extracellular Matrix Formation in Human Osteoblast-like MG-63 Cells

  • Lee, Jae-Bum;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Kim, Meyoung-Kon;Ryu, Jae-Jun
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • A variety of titanium (Ti) and its alloys are used in the clinical procedures of bone regeneration for periodontal and dental implant therapies. This study was performed to determine the effect of different surface dental implant materials on biologic responses of a MG-63 human osteoblast-like cell line. MG-63 cells were cultured on Ti coated with hydroxyapatite (HA), calcium metaphosphate (CMP), anodized (A), which compared with non-coated Ti (control). The appearances of surface of dental implant materials and the morphology of these cells were assessed by scanning electron microscopy (SEM). The gene expression profiles of MG-63 cells cultured on Ti were examined by human cDNA microarray (1,152 elements). The expression of several genes was up- and down-regulated by different surfaces of dental implant materials. Interesting, the genes correlated with cellular adhesion and extra cellular matrix (ECM) formation were enhanced, in accordance surface morphology of the dental implant materials used.

Considerations and clinical appliances of various abutments in implant prostheses (임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용)

  • Park, Sungwoo;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF

A STUDY ON CYTOTOXICITY OF THE NEW TITANIUM ALLOYS FOR DENTAL IMPLANT MATERIAL (Dental Implant 금속재료의 성분차이에 따른 세포독성에 관한 연구)

  • Kim, Tae-In;Han, Jun-Hyun;Lee, In-Seok;Lee, Kyu-Hwan;Shin, Myung-Chul;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.675-686
    • /
    • 1996
  • Today, dental implants are an acceptable alternative, capable of providing bone-anchored fixed prostheses for improved quality of life and self esteem for many patients. Research advances in dental implantology have led to the development of several different types of materials, and it is anticipated that continued research will likewise lead to advanced dental implant materials. Currently used pure titanium has relatively low hardness and strength which possibly limits its ability to resist the functional loads as a dental implant. Ti-6Al-4V also has potential problems such as corrosion resistance, bone biocompatibility etc. The carefully selected Zr, Nb, Ta, Pd, In constituents could improve mechanical strength, corrosion resistance, and biocompatibility compared to that of currently used implant metals. On the basis of the totality of the data from our study, it can be concluded that new titanium alloys containing Zr, Nb, Ta, Pd, In are able to provide improved mechanical properties, corrosion resistance and biocompatibility to warrant further investigation of it's potential as new biomaterials for dental implants.

  • PDF

Microgrooves on titanium surface affect peri-implant cell adhesion and soft tissue sealing; an in vitro and in vivo study

  • Lee, Hyo-Jung;Lee, Jaden;Lee, Jung-Tae;Hong, Ji-Soo;Lim, Bum-Soon;Park, Hee-Jung;Kim, Young-Kwang;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.120-126
    • /
    • 2015
  • Purpose: With the significance of stable adhesion of alveolar bone and peri-implant soft tissue on the surface of titanium for successful dental implantation procedure, the purpose of this study was to apply microgrooves on the titanium surface and investigate their effects on peri-implant cells and tissues. Methods: Three types of commercially pure titanium discs were prepared; machined-surface discs (A), sandblasted, large-grit, acid-etched (SLA)-treated discs (B), SLA and microgroove-formed discs (C). After surface topography of the discs was examined by confocal laser scanning electron microscopy, water contact angle and surface energy were measured. Human gingival fibroblasts (hGFs) and murine osteoblastic cells (MC3T3-E1) were seeded onto the titanium discs for immunofluorescence assay of adhesion proteins. Commercially pure titanium implants with microgrooves on the coronal microthreads design were inserted into the edentulous mandible of beagle dogs. After 2 weeks and 6 weeks of implant insertion, the animal subjects were euthanized to confirm peri-implant tissue healing pattern in histologic specimens. Results: Group C presented the lowest water contact angle ($62.89{\pm}5.66{\theta}$), highest surface energy ($45{\pm}1.2mN/m$), and highest surface roughness ($Ra=22.351{\pm}2.766{\mu}m$). The expression of adhesion molecules of hGFs and MC3T30E1 cells was prominent in group C. Titanium implants with microgrooves on the coronal portion showed firm adhesion to peri-implant soft tissue. Conclusions: Microgrooves on the titanium surface promoted the adhesion of gingival fibroblasts and osteoblastic cells, as well as favorable peri-implant soft tissue sealing.

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

Techniques for dental implant nanosurface modifications

  • Pachauri, Preeti;Bathala, Lakshmana Rao;Sangur, Rajashekar
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.498-504
    • /
    • 2014
  • PURPOSE. Dental implant has gained clinical success over last decade with the major drawback related to osseointegration as properties of metal (Titanium) are different from human bone. Currently implant procedures include endosseous type of dental implants with nanoscale surface characteristics. The objective of this review article is to summarize the role of nanotopography on titanium dental implant surfaces in order to improve osseointegration and various techniques that can generate nanoscale topographic features to titanium implants. MATERIALS AND METHODS. A systematic electronic search of English language peer reviewed dental literature was performed for articles published between December 1987 to January 2012. Search was conducted in Medline, PubMed and Google scholar supplemented by hand searching of selected journals. 101 articles were assigned to full text analysis. Articles were selected according to inclusion and exclusion criterion. All articles were screened according to inclusion standard. 39 articles were included in the analysis. RESULTS. Out of 39 studies, seven studies demonstrated that bone implant contact increases with increase in surface roughness. Five studies showed comparative evaluation of techniques producing microtopography and nanotopography. Eight studies concluded that osteoblasts preferably adhere to nano structure as compared to smooth surface. Six studies illustrated that nanotopography modify implant surface and their properties. Thirteen studies described techniques to produce nano roughness. CONCLUSION. Modification of dental osseous implants at nanoscale level produced by various techniques can alter biological responses that may improve osseointegration and dental implant procedures.

Conventional loading, is the concept still useful? (임상가를 위한 특집 3 - Conventional loading, 여전히 임상적으로 유용한가?)

  • Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.204-209
    • /
    • 2013
  • Implant-supported restorations were connected to commercially pure titanium endosteal implants 3 months in mandible and 6 months in maxilla after the implants were inserted into patient jaws. Modifications of titanium implant surfaces have reduced the waiting time for osseointegration, resulting in the development of the early loading concept, which is defined at present as a restoration in contact with the opposing dentition and placed at least 1 week after implant placement, but no later than 2 months afterward. Nowadays, immediate loading protocols have also been introduced, using the implants that are designed to enhance initial stability. Immediate loading eliminates the edentulous period of a patient. Although dentists widely accept these concepts of early and immediate loading, they agree the conventional loading concept is still necessary, which describes loading protocols later than 2 months after implant insertion. The timing of loading is determined mainly by the factors of a patient. This paper considers for what dental clinicians should be careful in implant-supported restoration procedures, considering the implant late failure.

Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process (Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석)

  • Lee, Seung-Mi;Jang, Jin-Man;Lee, Won-Sik;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.