• 제목/요약/키워드: titanium bar

검색결과 37건 처리시간 0.02초

AZ31마그네슘합금의 마찰접합특성 (Mechanical Properties of Friction Joint of AZ31Mg Alloy)

  • 공유식;천봉근;강대민
    • 소성∙가공
    • /
    • 제19권5호
    • /
    • pp.277-282
    • /
    • 2010
  • Magnesium alloy has been known as lightweight material in automobile and electronic industry with aluminum alloy, titanium alloy and plastic material. Friction welding is useful to join various metals and nonferrous metals that are difficult to join by such as gas welding, resistance welding and electronic beam welding. In this study, friction joining was performed to investigate mechanical properties of Mg alloy with 20mm diameter solid bar. Also the optimal joining conditions for its application were determined on the basis of tensile test, and hardness survey. The joining parameters were chosen as heating pressure, heating time, upsetting pressure, and upsetting time. Heating and upsetting pressure were executed under the range of 10~40MPa and 20~80MPa, respectively. From the experimental results, optimal joining conditions were determined as follows; rotating speed=2000rpm, heating pressure=35MPa, upsetting pressure=70MPa, heating time=1sec, upsetting time=5sec. Also the hardness of jointed boundary showed as HV50 which was similar to that of base metal at the optimal condition, and it was supposed that zone of HAZ was 8mm. Finally two materials were strongly mixed at interface part to show a well-combined microstructure without particle growth or any defect.

Osteotomy and iliac bone graft for the treatment of malunion caused by failed mandibular fracture reduction

  • Hwang, Kun;Ma, Sung Hwan
    • 대한두개안면성형외과학회지
    • /
    • 제21권6호
    • /
    • pp.384-386
    • /
    • 2020
  • This report describes osteotomy and iliac bone graft for malunion caused by failed mandibular fracture reduction. A 27-year-old man was referred 3 months after a motor vehicle accident. At another hospital, two operations had been performed for symphyseal fracture using two resorbable plates. Malocclusion was noted, and panoramic radiography and computed tomography revealed a misaligned dental arch, with a 9.37-mm gap between the central and the lateral incisor of the left mandible. A wafer was made from the patient's dental model, and a maxillary arch bar was applied. Through a lower gingivolabial incision, osteotomy was performed between the malunited symphyseal fracture segments. Both segments were reduced to their original position using the wafer and fixed with titanium miniplates via intermaxillary fixation (IMF). The intersegmental gap was filled with cancellous bone from the iliac crest. The gingival defect was covered with a mucosal transposition flap from the gingivolabial sulcus. IMF and the wafer were maintained for 5 and 9 weeks, respectively. At postoperative week 13, the screws were removed from the mandible and satisfactory occlusion was noted. His mouth opening improved from 2.5 to 3 finger breadths (40 mm). This case demonstrates the need for sufficient IMF when using resorbable plates.

20kHz 급 금속 초음파 융착용 스텝형 바 혼의 최적설계 (Analysis of Optimum Design of Stepped Bar Horn for 20kHz Metal Ultrasonic Welding)

  • 김지선;김재웅;김인주;서주환
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.94-101
    • /
    • 2019
  • 본 연구에서는 초음파 용접기의 진동에너지를 모재에 전달하는 금속 용접용 혼의 형상설계를 위해 해석적 기법을 적용하였으며, 20kHz 영역에서 사용되는 한파장 바 형상을 갖는 용접용 혼의 형상설계를 위해 FEM(Finite Element Method)을 사용하였다. 봉의 종진동 이론을 Ansys APDL(Ansys Parametric Design Language)에 적용하여 혼의 형상을 최적화하였다. 적절한 혼의 형상을 도출하기 위해 진동의 입력면과 출력면의 면적비와 혼의 축방향 길이비를 이용하여 총 25가지의 모델을 설계하였으며, Modal 해석과 Harmonic 해석을 통해 균일한 진동특성을 확보하고자 하였다. 스텝 바혼의 끝단부(팁)의 균일도 90%이상을 확보하기 위해 Harmonic 해석을 통해 길이비, 면적비를 결정하였고 이에 따라 혼의 총길이 130mm, 스텝 길이 65mm, 출력단 면적 28.79mm의 혼을 설계하였다. 설계치수를 바탕으로 Titanium (Ti-6Al-4V)-GR5 재료를 이용하여 혼을 제작하였다. 또한, 별도로 구성된 초음파 용접시스템을 이용하여 혼의 끝단부의 진동 진폭률 및 변위특성을 평가하였다. 최적화된 혼의 진폭률은 51%까지 향상됨을 확인하였다. 최종적으로 균일한 종방향 스텝 바혼을 설계하였으며, 끝단부(팁)의 균일도 97.4%이상을 확보하였다.

하악골 과두하 골절의 이하선 경유 접근법을 통한 관혈적 정복술 증례보고 (Case Report of Transparotid Approach of Mandibular Subcondylar Fracture)

  • 문민철;오석준;고성훈
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.33-36
    • /
    • 2009
  • Purpose: Fractures of the mandibular condylar area are common injuries that account for 29% to 40% of fractures of the facial bones and represent 20% to 62% of all mandibular fractures. Currently 3 main methods are being used in the treatment of mandibular subcondylar fractures: closed reduction; open reduction and internal fixation; Endoscopic reduction and internal fixation. Each method has its proponents and opponent as well as advantages and disadvantages, and indications for each vary among surgeons. There are six approaches of open reduction: submandibular, retromandibular, preaurilcular, postauricular, intraoral, transparotid approach. Among them, transparotid approach has been described for subcondylar exposure with dissection in the direction of facial nerve fibers to expose the bone through the parotid gland. This approach carries the risk of a parotid glandular fistula as well as facial nerve injury but has the advantage of being directly over the fracture site. We report safety and efficacy of surgical treatment using a transparotid approach for direct plating. Methods: A 43-year-old man sustained multiple facial bone fractures by driver traffic accident. Mandibular subcondyle was fractured and dislocated internally. We performed open reduction and internal fixation by transparotid approach. Fractured site was fixed by titanium mini plate & screw. We applicated arch bar for approximately 3 weeks. Results: Follow-up length was about 5months. Scar of surgical incision was indistinct, there was no symptoms and signs of facial nerve and parotid gland injury, and maximal mouth opening was measured 49.5 mm. Conclusion: Transparotid approach has high risks of facial nerve and parotid gland injury, but paradoxically it is the most effective technique in saving facial nerve. Open reduction and internal fixation of mandibular subcondylar fracture by transparotid approach with precise and versed procedure, best outcome can be expected.

Design and control of a proof-of-concept active jet engine intake using shape memory alloy actuators

  • Song, Gangbing;Ma, Ning;Li, Luyu;Penney, Nick;Barr, Todd;Lee, Ho-Jun;Arnold, Steve
    • Smart Structures and Systems
    • /
    • 제7권1호
    • /
    • pp.1-13
    • /
    • 2011
  • It has been shown in the literature that active adjustment of the intake area of a jet engine has potential to improve its fuel efficiency. This paper presents the design and control of a novel proof-of-concept active jet engine intake using Nickel-Titanium (Ni-Ti or Nitinol) shape memory alloy (SMA) wire actuators. The Nitinol SMA material is used in this research due to its advantages of high power-to-weight ratio and electrical resistive actuation. The Nitinol SMA material can be fabricated into a variety of shapes, such as strips, foils, rods and wires. In this paper, SMA wires are used due to its ability to generate a large strain: up to 6% for repeated operations. The proposed proof-of-concept engine intake employs overlapping leaves in a concentric configuration. Each leaf is mounted on a supporting bar than can rotate. The supporting bars are actuated by an SMA wire actuator in a ring configuration. Electrical resistive heating is used to actuate the SMA wire actuator and rotate the supporting bars. To enable feedback control, a laser range sensor is used to detect the movement of a leaf and therefore the radius of the intake area. Due to the hysteresis, an inherent nonlinear phenomenon associated with SMAs, a nonlinear robust controller is used to control the SMA actuators. The control design uses the sliding-mode approach and can compensate the nonlinearities associated with the SMA actuator. A proof-of-concept model is fabricated and its feedback control experiments show that the intake area can be precisely controlled using the SMA wire actuator and has the ability to reduce the area up to 25%. The experiments demonstrate the feasibility of engine intake area control using an SMA wire actuator under the proposed design.

게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선 (Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions)

  • 김삼동;이성대;이진구;황인석;박대규
    • 한국재료학회지
    • /
    • 제10권12호
    • /
    • pp.812-818
    • /
    • 2000
  • 본 연구에서는 Ge PAM이 선폭 미세화에 따른 C54 실리사이드화 및 실제 CMOS 트랜지스터 접합부에서의 각종 전기적 특성에 미치는 영향을, As PAM과의 비교를 통하여 관찰하였다. 평판 상에서 각 PAM 및 기판의 도핑 상태에 따른 Rs의 변화량을 측정하였으며, 각 PAM 방식은 기존의 살리사이드 TiSi$_2$에 비해 개선된 C54 형성 효과를 보였다. 특히, Ge PAM은 n+ 기판에서 As PAM보다 효과적인 실리사이드화를 보였고, 이 경우 XRB 상에서도 가장 강한 (040) C54 배향성을 나타내었다. ~0.25$\mu\textrm{m}$ 선폭 및 n+ 접합층에서 기존 방식에 비해 As과 Ge PAM은 각각 ~85,66%의 개선된 바저항을 보였으며, P+ 접합층에서는 As과 Ge PAM 모두 62~63% 정도의 유사한 Rs 개선 효과를 보였다. 콘택 저항에서도 각 콘택 크기 별로 바저항(bar resistance) 개선과 같은 경향의 PAM 효과를 관찰하였으며, 모든 경우 10 $\Omega$/ct. 이하로 양호한 결과를 보였다. 누설 전류는 area 형 패턴에서는 모든 공정 조건에서 <10E-14A/$\mu\textrm{m}^{2}$ 이하로, edge 형에서는 특히 P+ 접합부에서 As 또는 Ge PAM 적용 시 <10E-13 A/$\mu\textrm{m}^{2}$ 이하로 다소 누설 전류를 안정화시키는 결과를 보였다. 이러한 결과는 XTEM에 의해 관찰된 바 Ge PAM 적용 시 기존의 경우에 (PAM 적용 안한 경우) 비해 유사한 평활도의 TiSi$_2$박막 형상과 일치하였으며, 또한 본 실험의 Ge PAM 이온주입 조건이 접합층에 손상을 주지 않는 범위에서 적정화되었음을 제시하였다

  • PDF

브레이징 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성 (Brazing characteristics of $ZrO_2$ and Ti-6Al-4V brazed joints with increasing temperature)

  • 기세호;박상윤;허영구;정재필;김원중
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.169-175
    • /
    • 2012
  • 연구 목적: 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성에 대해 알아보기 위하여 새로운 브레이징 합금을 제조하고, 브레이징 온도가 접합 특성에 미치는 영향에 대하여 조사하고자 하였다. 연구 재료 및 방법: 본 연구에서 사용된 시편으로는 실험용 $ZrO_2$ 모재(ZirBlank-PS, Acucera, Inc., Gyeonggi-do, Korea)는 소결 전의 블록형태($65mm{\times}36mm{\times}12mm(t)$)이며, 이를 잘라 사포(#2400)로 표면연마 후 소결하였다. 소결된 $ZrO_2$ 시편의 크기는 $3mm{\times}3mm{\times}3mm(t)$이다. Ti-6Al-4V 모재(Ti 6Al 4V ELI CG Bar, TMS, Washington, USA)는 직경 $10mm{\times}5mm(t)$를 사용하였다. 소결된 $ZrO_2$와 Ti-6Al-4V의 접합을 위하여 브레이징 합금을 제조하였다. 시편을 3군으로 나누어 A군은 $700^{\circ}C$에서, B군은 $750^{\circ}C$에서, C군은 $800^{\circ}C$에서 각각 브레이징 하였다. 브레이징 부의 두께와 결함율의 측정은 각 군당 하나의 시편으로 각 시편 당 5회씩 반복 측정하여 평균값을 취하였다. 결과: 브레이징 합금을 사용하여 진공 브레이징을 수행한 결과 $ZrO_2$ 와 Ti-6Al-4V 는 $700^{\circ}C-800^{\circ}C$에서 양호한 접합을 보였다. 브레이징 후 브레이징 온도 변화에 따른 브레이징 부의 두께 및 결함율의 변화는 SEM을 사용하여 측정하였다. 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 CuTi 금속간 화합물 층 및 Ti-Sn-Cu-Ag계 화합물 층의 두께는 각각 $4.5{\mu}m$에서 $10.3{\mu}m$로, $3.1{\mu}m$에서 $5.0{\mu}m$로 증가되었다. 또한 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 각각 25%에서 16.3%, 5%에서 1.5%로 감소되었다. 결론: 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가됨에 따라, 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 모두 감소되었다. 이는 결함부에서 $ZrO_2$와 활성원소인 Ti과의 반응이 충분히 일어나지 않아서 브레이징 합금이 $ZrO_2$에 웨팅되지 않은 것이 원인이라고 사료된다.