• Title/Summary/Keyword: time of concentration ratio

Search Result 1,294, Processing Time 0.027 seconds

Greenhouse gases emission from aerobic methanotrophic denitrification (AeOM-D) in sequencing batch reactor

  • Lee, Kwanhyoung;Choi, Oh Kyung;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.171-184
    • /
    • 2017
  • This study presents the effect of hydraulic retention time (HRT) on the characteristics of emission of three major greenhouse gases (GHGs) including $CH_4$, $CO_2$ and $N_2O$ during operation of a sequencing batch reactor for aerobic oxidation of methane with denitrification (AeOM-D SBR). Dissolved $N_2O$ concentration increased, leveled-off and slightly decreased as the HRT increased from 0.25 to 1d. Concentration of the dissolved $N_2O$ was higher at the shorter HRT, which was highly associated with the lowered C/N ratio. A longer HRT resulted in a higher C/N ratio with a sufficient carbon source produced by methanotrophs via methane oxidation, which provided a favorable condition for reducing $N_2O$ formation. With a less formation of the dissolved $N_2O$, $N_2O$ emission rate was lower at a longer HRT condition due to the lower C/N ratio. Opposite to the $N_2O$ emission, emission rates of $CH_4$ and $CO_2$ were higher at a longer HRT. Longer HRT resulted in the greater total GHGs emission as $CO_2$ equivalent which was doubled when the HRT increased from 0.5d to 1.0 d. Contribution of $CH_4$ onto the total GHGs emission was most dominant accounting for 98 - 99% compared to that of $N_2O$ (< 2%).

Influence of Organic Acids Residual Concentration by the Change of F/M Ratio on Sludge Settleability in Advanced Sewage Treatment Processes (하.폐수 고도처리시 F/M비 변화에 따른 유기산 잔류 농도가 슬러지 침강성에 미치는 영향)

  • Park, Young-Ki;Kim, Young-Il;Kim, Sl-Ki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • The biological nutrient treatment is formed with repetition and rearrangement of anaerobic, anoxic and oxic tank. In this case, VFAs is generated in the anaerobic tank and the anoxic tank. The VFAs is an important factor for removal of nitrogen and phosphate and SVI. So, in this study I investigated to find a relationship among the generation rate of the VFAs according to the change of F/M ratio and the characteristic which can eliminate organic matter and nitrogen according to the change of residual concentration of the VFAs and the efficiency of the process and also SVI in wastewater treatment. $A^2/O$ process was used for wastewater treatment. F/M ratio was under the control of the change of MLSS concentration. When the F/M ratio was changed from 0.16 to 0.08 kg-BOD/kg-MLSS/day, the VFAs's production volume increased based on the reduction of F/M ratio in batch reaction. And the residual concentration of the VFAs decreased at first and then increased later. SVI and SS were high when F/M ratio was $0.16kg/kg{\cdot}d$ and showed stable status when F/M ratio decreased $0.11{\sim}0.13kg/kg{\cdot}d$. However, SVI and SS continuously increased with decrease of F/M ratio and were high at $0.08kg/kg{\cdot}d$. In the result of comparison between residual concentration of the VFAs and denitrification rate in anoxic tank, the less residual volume of the VFAs was in anoxic tank, the higher denitrification ratio became. The optimal residual-concentration of the VFAs considering SVI and removal efficiency of nitrogenwas $1.4{\sim}2.2mg/L$. At that time F/M ratio was $0.11{\sim}0.13$ kg-BOD/kg-MLSS/day.

The Effect of Outdoor Air and Indoor Human Activity on Mass Concentrations of Size-Selective Particulate in Classrooms (대기오염과 실내 거주자의 활동도가 교실 내부의 입자 크기별 먼지 농도에 미치는 영향)

  • Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • This study evaluated the effects of the human activity and outdoor air on concentrations of size-selective particulate matters (PM) by conducting a realtime measurement in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. PM concentrations featured repetitive pattern of increasing during break time (including lunch hours) and cleaning time while decreasing during class hours. This trend was more prominent with inhalable PM and PM10 than fine PMs (PM2.5, PM1.0). The indoor/outdoor (I/O) ratio of inhalable PM and PM10 exceeded 1 while that of fine PMs was close to or below 1. The PM2.5 (out)/PM10 (out) ratio stood at 0.59 (${\pm}0.16$) and the PM2.5 (in)/PM10 (in) ratio was 0.29 (${\pm}0.09$), suggesting that occupant activity had a greater effect upon coarse particles (PM10-PM2.5) than upon fine particles (PM2.5, PM1.0). The correlations between the indoor and the outdoor PM concentrations showed a stronger positive correlation for fine particles than that of coarse particles. The linear regression analysis of PM concentrations indoor and outdoor indicated a higher determinant coefficient ($r^2>0.9$), and consistency for fine particles than in case of coarse particles. In conclusion, the results of this study suggest that the indoor coarse particle concentration is more attributed to occupant activity and the indoor fine particle concentration is more influenced by outdoor air pollution.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

An Analysis of Characteristic Parameters for the Design of Detention Pond in Urbanized Area (도시유역에서 저류지 설계를 위한 특성인자 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.37-47
    • /
    • 2006
  • Urban development results in increased runoff volume and flowrates and shortening in time of concentration, which may cause frequent flooding downstream. Flow retardation structures to limit adverse downstream effects of urban storm runoff are used. There are various types of flow retardation measures include detention basins, retention basins, and infiltration basins. In basic planning phase, a number of planning models of detention ponds which decide storage volume by putting main variables were used to design detention ponds. The characteristics of hydrological parameters $\alpha,\;\gamma$ which are used in planning models of detention pond were analyzed. In this study, detention ponds data of Disaster Impact Assessment report at 22 sites were analyzed in order to investigate correlation between characteristic of urban drainage basin parameter and characteristics of detention pond parameter due to urbanization effects. The results showed that storage volume was influenced by peak discharge ratio $\alpha$ more than runoff coefficient ratio $\beta$ and peak discharge ratio $\alpha$ was influenced by runoff coefficient ratio $\beta$ less than regional parameter n. Storage ratio was mainly influenced by duration of design rainfall in the case of trapezoidal inflow hydrograph such as Donahue et al. method.

Acid Hydrolysis Characteristics of Yellow Poplar for High Concentration of Monosaccharides Production (백합나무를 이용한 고농도 단당류 생산을 위한 산 가수분해 특성 연구)

  • Shin, Soo-Jeong;Park, Jong-Moon;Cho, Dae Haeng;Kim, Yong Hwan;Cho, Nam-Seok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.578-584
    • /
    • 2009
  • We investigated acid hydrolysis characteristics of yellow poplar woodmeal with concentrated sulfuric acid for high concentration of monosaccharides production. Woodmeal to 72% sulfuric acid ratio (w/w), $2^{nd}$ hydrolysis temperature and time were main variables for finding optimum reaction condition. Optimum woodmeal to 72% sulfuric acid ratio was 1 : 2.61 (w/w) and $2^{nd}$ hydrolysis temperature and time was $105^{\circ}C$ and 40 min as 44.8 g/L of glucose and 25.2 g/L of xylose in hydrolysis solution. In this acid hydrolysis solution, furfural, 5-HMF, low molecular weight phenolic compounds were identified. Furfural and 5-HMF concentration were increased as increasing $2^{nd}$ hydrolysis time. More than 40 min of $2^{nd}$ hydrolysis at $110^{\circ}C$, xylose concentration was decreased but glucose concentration was leveled out because xylose to furfural reaction was faster than xylan to xylose, but cellulose to glucose reaction was similar rate with glucose to 5-HMF at that $2^{nd}$ hydrolysis reaction condition.

Preparation of Porous Cobalt Thin Films by Using an Electrochemical Method (전기화학적 방법을 통한 다공성 코발트 박막 합성)

  • Ha, Seong-Hyeok;Shin, Heon-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.6
    • /
    • pp.312-321
    • /
    • 2020
  • Morphology of porous cobalt electro-deposits was systematically investigated as functions of cobalt precursors in the plating bath and applied cathodic current density with a special focus on cobalt nano-rod formation. It was proved that the concentration of cobalt precursor plays little effect on the morphology of cobalt electro-deposits at relatively low plating current density while it significantly affects the morphology with increasing plating current density. Such a dependence was discussed in terms of the kinetics of two competitive reactions of cobalt reduction and hydrogen evolution. Cobalt nano-rod structure was created at specific ranges of cobalt precursor content and applied cathodic current density, and its diameter and length varied with plating time without notable formation of side branches which is usually found during dendrite formation. Specifically, the nano-rod length was preferentially increased in relative short plating time (<15 s), resulting in higher aspect ratio of nano-rod with plating time. Whereas, both the nano-rod length and diameter were increased nearly at the same level in a prolonged plating time, making the aspect ratio unchanged. From the analysis of crystal structure, it was confirmed that the cobalt nano-rod preferentially grew in the form of single crystal on a dense poly-crystalline cobalt thin film initially formed on the substrate.

Bioequivalence of Boryung Torsemide Tablet to Torem Tablet (Torasemide 10 mg) by High Performance Liquid Chromatography/UV Detector

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Chan-Ho;Kim, Se-Mi;Kim, Dong-Ho;Park, Sun-Ae;Kim, Kyung-Ran;Hur, Hyeon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two torasemide tablets, Torem tablet (Roche Korea Co., Ltd., Korea, reference drug) and Boryung Torsemide tablet (Boryung Pharmaceutical Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (furosemide) to human serum, serum samples were extracted using 5 mL of ethyl acetate. Compounds were analyzed by reverse-phase HPLC method with UV detection. This method showed linear response over the concentration range of 0.05 ug/mL with correlation coefficient of 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ug/mL which was sensitive enough for pharmacokinetic studies. Twenty-eight healthy male Korean volunteers received each medicine at the torasemide dose of 20 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of torasemide were monitored by an HPLC-UV for over a period of 12 hr after the administration. $AUC_{t}$(the area under the serum concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum serum drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{t}$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_{t}$ ratio and the $C_{max}$ ratio for Boryung Torsemide/Torem were log 0.97-10g 1.03 and log 0.93log 1.12, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Boryung Torsemide tablet and Torem tablet are bioequivalent.

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.5
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.

Time-Temperature-Transition Diagrams with Liquid Crystalline Phase Changes of Liquid Crystalline Epoxy (열경화성 액정 에폭시 수지의 액정상 변화를 포함한 시간-온도-전이 다이어그램)

  • Seung Hyun Cho
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.215-218
    • /
    • 2024
  • Liquid crystalline thermosetting epoxy oligomer DD-A was synthesized with Diglycidyl ether of 4,4'-dihydroxy-α-methylstilbene (DGE-DHMS) and aniline in a ratio of 2:1 and cured with a catalytic curing agent, 1-Methyl Imidazole. The gelation times and vitrification times were measured to create Time-Temperature-Transition Diagrams with liquid crystalline phase changes. It was found that the gelation and vitrification times were decreased as the concentration of curing agent increased, and the vitrification curve showing a typical S-shape was confirmed.