• Title/Summary/Keyword: tilt angle

Search Result 629, Processing Time 0.033 seconds

A Study on Apply of Smart Sensors for Wheelchair Balancing Control (휠체어 균형 조정을 위한 스마트 센서의 적용에 관한 연구)

  • Ma, Linh Van;Cho, Young-bin;Kim, Jinsul
    • Journal of Digital Contents Society
    • /
    • v.19 no.8
    • /
    • pp.1585-1592
    • /
    • 2018
  • Due to un-balancing weight allocation on the wheelchair the existing wheelchair system are faced with the risk of flipping or falling when a wheelchair goes up to a hill. In to order to be safer during riding the wheelchair, in this paper, we proposed a real-time new solution using the integrated Gyro Sensor and Tilt Sensor for controlling the balance. Because the typical property of wheelchair is for the special user who meets the difficulty in moving on foot the maintain the balance of wheel-chair systems have become important and helpful. In our method, we calculate the seat angle using information from Tilt Sensor. However, due to the law of inertia when a wheelchair is moving there is a deviation in the output value of Tilt Sensor. Therefore, we have to optimize the value of the angle by utilizing the acceleration that is the output of the Gyro Sensor. We took the advantages by using the combination of Gyro and Tilt sensors. Moreover, we also solved the consumption issue of the whole system. Through various experimentations with usage of ZigBee sensor module, the power consumption for the balancing system is reduced significantly.

External Tibial Torsion with Proximal Tibia Vara in Total Knee Arthroplasty of Advanced Osteoarthritis with Severe Varus Deformed Knees (심한 내반 변형의 진행성 관절염 환자의 인공 슬관절 전치환술 시 경골 근위부의 내반을 동반한 외회전 변형)

  • Sun, Doo-Hoon;Song, In-Soo;Kim, Jun-Beom;Kim, Cheol-U;Jung, Deukhee;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.62-70
    • /
    • 2020
  • Purpose: External tibia torsion and proximal tibial vara have been reported in severe varus deformed osteoarthritis, which is a tibio-femoral angle of more than 20°. The radiology measurements were compared with those of control group and the preoperative and follow-up radiology and clinical results were examined. Materials and Methods: From January 2007 to March 2016, 43 knees from 37 persons, who underwent total knee arthroplasty for a severe varus deformity of more than 20° on the tibio-femoral angle on the standing radiographs and had a follow-up period more than two years, were examined. The mean follow-up period was 45.7 months. The control group, who underwent conservative treatments, had Kellgren-Lawrence grade three osteoarthritis and a tibio-femoral angle of less than 3° varus. The external tibial torsion of enrolled patients and control group were estimated using the proximal tibio-fibular overlap length and the tibial torsion values on computed tomography. The proximal tibia vara was measured using the proximal tibial tilt angle. The preoperative and postoperative proximal tibio-fibular overlap length, tibial torsion value, proximal tibial tilt angle, and hospital for special surgery (HSS) score were evaluated. Results: The mean proximal tibio-fibular overlap length was 18.6 mm preoperatively and 11.2 mm (p=0.031) at the follow-up. The control group had a mean proximal tibio-fibular overlap length of 8.7 mm (p=0.024). The mean tibial torsion value was 13.8° preoperatively and 14.0° (p=0.489) at the follow-up. The control group had a mean tibial torsion value of 21.9° (p=0.012). The mean proximal tibial tilt angle was 12.2° preoperatively and 0° (p<0.01) at the follow-up. The control group had a mean proximal tilt angle of 1.2° (p<0.01). The preoperative tibiofemoral angle and mechanical axis deviation were corrected from preoperative 28.3° and medial 68.4 mm to postoperative 0.7° and medial 3.5 mm (p<0.01, p<0.01), respectively. The HSS scores increased from 34 points of preoperatively to 87 points at the last follow-up (p=0.028). Conclusion: Patients with advanced osteoarthritis with a severe varus deformity of more than 20° had significant increases in the external tibial torsion and varus of the proximal tibia. The tibial torsion value before and after surgery in the enrolled patients was not changed statistically, but good clinical results without complications were obtained.

Study on orientation distribution of discotic liquid crystal in compensating film for viewing angle improvement of liquid crystal displays

  • Ryu, J.W.;Shin, Y.S.;Kim, Y.K.;Kim, S.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.879-882
    • /
    • 2008
  • The discotic liquid crystal in compensating film used for the viewing angle improvement of the twist nematic liquid crystal display panel is analyzed. For the optical characterization of the compensating film, we measured the polarization state of the light passing through the film as the tilt angle and the azimuth angle of the film were varied, and then we compared the measured polarization state with the calculated one. Finally we suggested the best fit configuration of the discotic liquid crystal.

  • PDF

Development of an Initial Coarse Alignment Algorithm for Strapdown Inertial Navigation System (스트랩다운 관성항법시스템의 초기 개략정렬 알고리즘 개발)

  • 박찬국;김광진;박흥원;이장규
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.5
    • /
    • pp.674-679
    • /
    • 1998
  • In this paper, a new coarse alignment algorithm is proposed for roughly determining the initial attitude of the vehicle. The algorithm, referred as two-step coarse alignment algorithm, computes roll and pitch angle of the vehicle using accelerometer outputs, and then determines yaw angle with gyro outputs. With the geometric relation between sensor outputs and attitude angles, the algorithm error is analytically derived and compared with the previous coarse alignment algorithm that computes a transformation matrix using accelerometer md gyro outputs simultaneously. The simulation is also performed by varying the sensor errors. The results show that the proposed two-step coarse alignment algorithm has better performance for east tilt angle.

  • PDF

The effect of Ion Beam modification of Polyimide surface on alignment properties of liquid crystals

  • Cho, Seong-Jin;Kim, Chan-Soo;Roh, Jin-A;Gwag, Jin-Seog;Kim, Jae-Chang
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.107-112
    • /
    • 2003
  • The alignment effect of liquid crystals on Polyimide surfaces bombarded by a low energy argon ion beam and the effect of pretilt angle on viewing characteristics of an LCD cell are discussed. The unidirectional out-of-plane liquid crystal tilt angle is varied with various ion beam irradiation conditions, such as the energy of the incident ions, the angle of incidence and exposure time. As low pretilt angle is profitable for wider viewing property, LCD cell with ion beam modified Polyimide layer show wider viewing characteristics.

Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults (정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측)

  • Shon, Hyun-Chul;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Hong, Kyung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.

Robust Adaptive Nonlinear Control for Tilt-Rotor UAV

  • Yun, Han-Soo;Ha, Cheol-Keun;Kim, Byoung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.57-62
    • /
    • 2004
  • This paper deals with a waypoint trajectory following problem for the tilt-rotor UAV under development in Korea (TR-KUAV). In this problem, dynamic model inversion based on the linearized model and Sigma-Phi neural network with adaptive weight update are involved to realize the waypoint following algorithm for the vehicle in the helicopter flight mode (nacelle angle=0 deg). This algorithms consists of two main parts: outer-loop system as a command generator and inner-loop system as stabilizing controller. In this waypoint following problem, the position information in the inertial axis is given to the outer-loop system. From this information, Attitude Command/Attitude Hold logic in the longitudinal channel and Rate Command/Attitude Hold logic in the lateral channel are realized in the inner-loop part of the overall structure of the waypoint following algorithm. The nonlinear simulation based on the TR-KUAV is carried out to evaluate the stability and performance of the algorithm. From the numerical simulation results, the algorithm shows very good tracking performance of passing the waypoints given. Especially, it is observed that ACAH/RCAH logic in the inner-loop has the satisfactory performance due to adaptive neural network in spite of the model error coming from the linear model based inversion.

  • PDF

Structural Vibration Analysis for a Composite Smart UAV Considering Dynamic Hub-loads of the Tilt-rotor (틸트로터 허브 동하중을 고려한 복합재 스마트 무인기 진동해석)

  • Kim, Dong-Hyun;Jung, Se-Un;Koo, Kyo-Nam;Kim, Sung-Jun;Kim, Sung-Chan;Lee, Ju-Young;Choi, Ik-Hyeon;Lee, Jung-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.63-71
    • /
    • 2005
  • In this study, structural vibration analyses of a composite smart unmanned aerial vehicle (UAV) have been conducted considering dynamic hub-loads of tilt-rotor. Practical computational structural dynamics technique based on the finite element method is applied using MSC/NASTRAN. The present smart UAV(TR-S2) structural model is constructed as full 3D configurations with both the helicopter flight mode and the airplane flight mode. Modal based transient response and frequency response analyses are used to efficiently investigate vibration characteristics of structure and installed electronic equipments. It is typically shown that the helicopter flight mode with the 90-deg tilting angle is the most critical case for the induced vibration of installed electronic equipments in the front.

Attitude Estimation for the Biped Robot with Vision and Gyro Sensor Fusion (비전 센서와 자이로 센서의 융합을 통한 보행 로봇의 자세 추정)

  • Park, Jin-Seong;Park, Young-Jin;Park, Youn-Sik;Hong, Deok-Hwa
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.546-551
    • /
    • 2011
  • Tilt sensor is required to control the attitude of the biped robot when it walks on an uneven terrain. Vision sensor, which is used for recognizing human or detecting obstacles, can be used as a tilt angle sensor by comparing current image and reference image. However, vision sensor alone has a lot of technological limitations to control biped robot such as low sampling frequency and estimation time delay. In order to verify limitations of vision sensor, experimental setup of an inverted pendulum, which represents pitch motion of the walking or running robot, is used and it is proved that only vision sensor cannot control an inverted pendulum mainly because of the time delay. In this paper, to overcome limitations of vision sensor, Kalman filter for the multi-rate sensor fusion algorithm is applied with low-quality gyro sensor. It solves limitations of the vision sensor as well as eliminates drift of gyro sensor. Through the experiment of an inverted pendulum control, it is found that the tilt estimation performance of fusion sensor is greatly improved enough to control the attitude of an inverted pendulum.

The Effects of Growth Temperature and Substrate Tilt Angle on GalnP/GaAs Tandem Solar Cells

  • Jun, Dong-Hwan;Kim, Chang-Zoo;Kim, Hog-Young;Shin, Hyun-Beom;Kang, Ho-Kwan;Park, Won-Kyu;Shin, Ki-Soo;Ko, Chul-Gi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • The performance of GaInP/GaAs tandem solar cells with AlInP growth temperatures of 680$^{\circ}C$ and 700 $^{\circ}C$ on n-type GaAs (100) substrate with 2$^{\circ}$ and 6$^{\circ}$ tilt angles has been investigated. The series resistance and open circuit voltage of the fabricated tandem solar cells are affected by the substrate tilt angles and the growth temperatures of the window layer when zinc is doped in the tunnel diode. With carbon doping as a p-type doping source in the tunnel diode and the effort of current matching between top and bottom cells, GaInP/GaAs tandem solar cell has been exhibited 25.58% efficiency.