• Title/Summary/Keyword: thyroid imaging

Search Result 161, Processing Time 0.027 seconds

Fusion of Gamma and Realistic Imaging (감마영상과 실사영상의 Fusion)

  • Kim, Yun-Cheol;Yu, Yeon-Uk;Seo, Young-Deok;Moon, Jong-Woon;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • Purpose: Recently, South Korea has seen a rapidly increased incidence of both breast and thyroid cancers. As a result, the I-131 scan and lymphoscintigraphy have been performed more frequently. Although this type of diagnostic imaging is prominent in that visualizes pathological conditions, which is similar to previous nuclear diagnostic imaging techniques, there is not much anatomical information obtained. Accordingly, it has been used in different ways to help find anatomical locations by transmission scan, however the results were unsatisfactory. Therefore, this study aims to realize an imaging technique which shows more anatomical information through the fusion of gamma and realistic imaging. Materials and Methods: We analyzed the data from patients who were examined by the lymphoscintigraphy and I-131 additional scan by Symbia Gamma camera (SIEMENS) in the nuclear medicine department of the National Cancer Center from April to July of 2009. First, we scanned the same location in patients by using a miniature camera (R-2000) in hyVISION. Afterwards, we scanned by gamma camera. The data we obtained was evaluated based on the scanning that measures an agreement of gamma and realistic imaging by the Gamma Ray Tool fusion program. Results: The amount of radiation technicians and patients were exposed was generated during the production process of flood source and applied transmission scan. During this time, the radiation exposure dose of technicians was an average of 14.1743 ${\mu}Sv$, while the radiation exposure dose of patients averaged 0.9037 ${\mu}Sv$. We also confirmed this to matching gamma and realistic markers in fusion imaging. Conclusion: Therefore, we found that we could provide imaging with more anatomical information to clinical doctors by fusion of system of gamma and realistic imaging. This has allowed us to perform an easier method in which to reduce the work process. In addition, we found that the radiation exposure can be reduced from the flood source. Eventually, we hope that this will be applicable in other nuclear medicine studies. Therefore, in order to respect the privacy of patients, this procedure will be performed only after the patient has agreed to the procedure after being given a detailed explanation about the process itself and its advantages.

  • PDF

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.

A Rare Case of Hyponatremia Caused by Reset Osmostat in a Neonate with Cleft Lip, Cleft Palate, and Imperforate Anus

  • Ahn, Jung Gu;Lee, Jeong Eun;Chung, Woo Yeong;Koo, Soo Hyun;Shin, Jaeho;Jeon, Ga Won
    • Neonatal Medicine
    • /
    • v.25 no.3
    • /
    • pp.131-135
    • /
    • 2018
  • Hyponatremia is defined as a plasma sodium concentration of <135 mEq/L. It is a common electrolyte imbalance in newborns. We report the case of a term neonate with cleft lip, cleft palate, imperforate anus, normal male karyotype, and chronic hyponatremia. On the 4th day of life, he showed hyponatremia (plasma sodium concentration 130 mEq/L) with low serum osmolality (275 mOsm/kg), high urine sodium (116.7 mEq/L), and high urine osmolality (412 mOsm/kg). His thyroid and adrenal functions were normal. Despite intravenous and oral sodium supplementation and hydrocortisone treatment, hyponatremia persisted. Brain magnetic resonance imaging showed normal results. He was diagnosed as having reset osmostat, a rare subtype of the syndrome of inappropriate secretion of antidiuretic hormone characterized by a subnormal threshold for antidiuretic hormone secretion, with hypotonic hyponatremia.

New daily persistent headache with isolated sphenoiditis in children

  • Lee, Jeongho;Rhee, Minhee;Suh, Eun Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.2
    • /
    • pp.73-76
    • /
    • 2015
  • Isolated sphenoid sinusitis is a rare disease in children, and its symptoms are often nonspecific and confusing. Rarely, severe headache can be the first or only symptom of isolated sphenoid sinusitis. New daily persistent headache (NDPH) is a form of chronic daily headache that may have features of both migraines and tension-type headaches. NDPH is difficult to diagnose and requires a multifaceted approach. Here, we report on a 10-year-old boy and an 11-year-old girl who both presented with typical NDPH symptoms. These patients had no nasal symptoms or signs of infection. Neither nonsteroidal anti-inflammatory drugs nor topiramate had any effect on the headaches. Their neurological and ophthalmological examinations were normal. The results of routine blood work, including thyroid function tests, inflammatory markers, complete blood count, tests for viral infection, and a metabolic panel, were normal. A brain magnetic resonance imaging scan showed isolated sphenoid sinusitis. Both patients' symptoms resolved completely after approximately 1 month of oral antibiotics for sinusitis.

Tc-99m-MIBI Uptake in Active Pulmonary Tuberculosis : A Case Report (활동성 폐 결핵에서의 Tc-99m-MIBI 섭취 : 1예 보고)

  • Lee, Chang-Ho;Park, Chan-Hee;Hwang, Hee-Sung;Bae, Moon-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.379-381
    • /
    • 1996
  • Technetium-99m MIBI was developed as a myocardiac perfusion imagine agent and has been used effectively in the detection and post-therapeutic evaluation of various neoplasm such as thyroid, lung, bone and breast tumors. As an infrequent findings, Tc-99m MIBI agent has shown in non-neoplastic pulmonary conditions Including fibrosing alveolitis, pulmonary actinomycosis, active pulmonary sarcoidosis, pulmonary interstitial fibrosis in progressive systemic sclerosis and active osteomyelitis. In a recent report conducted by Cetin Oncel, Tc-99m MIBI imaging is an effective method in the detection and follow-up of pulmonary tuberculosis We have also experienced Tc-99m MIBI uptake in active pulmonary tuberculosis incidentally found in a patient with suspected proliferative villonodular synovitis of the left ankle.

  • PDF

Immunoglobulin G4-Related Disease Involving Various Head and Neck Regions: A Case Report (두경부에 국한된 표현형으로 발생한 면역글로불린 G4와 연관된 질환: 증례 보고)

  • Jun Yong Im;Miok Sunwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.910-917
    • /
    • 2022
  • Immunoglobulin G4 (IgG4) related disease (IgG4-RD) is currently considered an immune-mediated condition and is recognized as a disorder group with common pathological, hematological, and clinical characteristics. This disease may involve diverse organs of the head and neck, and include mainly the lacrimal gland, orbit, thyroid gland, pituitary gland, and the meninges. Here, we report a case of IgG4-RD in a 65-year-old female showing head- and neck-limited but synchronously and mainly manifesting as otalgia and facial neuritis.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.

Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan (분화 갑상선암 수술 후 최초 고용량 방사성옥소 치료시 투여용량 결정: 병리적 병기, 혈청 갑상선글로불린치와 I-123 전신 스캔의 유용성 비교)

  • Jeong, Hwan-Jeong;Lim, Seok-Tae;Youn, Hyun-Jo;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.301-306
    • /
    • 2008
  • Purpose: Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Materials and Methods: Fifty eight patients (M:F=13;45, age $44.5{\pm}11.5\;yrs$) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. Results: All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, fourty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were $154{\pm}25\;mCi$ in stage I (n=9), $175{\pm}50\;mCi$ in stage II (n=4), $149{\pm}21\;mCi$ in stage III (n=38), and $161{\pm}20\;mCi$ in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with $149{\pm}26\;mCi$ of I-131, 9 patients (17.3%) having $2{\leq}\;sTG\;<5\;ng/mL$ with $156{\pm}17\;mCi$, 5 patients (9.6%) having $5{\leq}\;sTG\;<10\;ng/mL$ with $156{\pm}13\;mCi$, 7 patients (13.5%) having $10{\leq}sTG\;<50\;ng/mL$ with $147{\pm}24\;mCi$, and 6 patients (11.5%) having above 50 ng/mL with $175{\pm}42\;mCi$. The statistical significance between sTG level and TD (p=0.252) was not shown. Conclusion: In conclusion, PS and sTG could not replace the determination of TD using I-123 scan for first HD-RAI in patients with differentiated thyroid cancer.

Transcriptional and Nontranscriptional Regulation of NIS Activity and Radioiodide Transport (NIS 기능의 전사 및 전사외 조절과 방사성옥소 섭취)

  • Jung, Kyung-Ho;Lee, Kyung-Han
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.343-349
    • /
    • 2007
  • Radioiodide transport has been extensively and successfully used in the evaluation and management of thyroid disease. The molecular characterization of the sodium/iodide symporter (NIS) and cloning of the NIS gene has led to the recent expansion of the use of radioiodide to cancers of the breast and other nonthyroidal tissues exogenously transduced with the NIS gene. More recently, discoveries regarding the functional analysis and regulatory processes of the NIS molecule are opening up exciting opportunities for new research and applications for NIS and radio iodide. The success of NIS based cancer therapy is dependent on achievement of maximal radioiodide transport sufficient to allow delivery of effective radiation doses. This in turn relies on high transcription rates of the NIS gene. However, newer discoveries indicate that nontranscriptional processes that regulate NIS trafficking to cell membrane are also critical determinants of radioiodide uptake. In this review, molecular mechanisms that underlie regulation of NIS transcription and stimuli that augment membrane trafficking and functional activation of NIS molecules will be discussed. A better understanding of how the expression and cell surface targeting of NIS proteins is controlled will hopefully aid in optimizing NIS gene based cancer treatment as well as NIS based reporter-gene imaging strategies.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF