• Title/Summary/Keyword: thyroid gland dose

Search Result 82, Processing Time 0.037 seconds

Design of Simple Shielding Handkerchief to Protect the Passenger's Thyroid (비행기 이용승객의 갑상선 차폐를 위한 간편한 손수건 고안)

  • Jung, Hongmoon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.87-93
    • /
    • 2019
  • Recently, the number of passengers using airplanes is rapidly increasing due to the increase of overseas travelers. Therefore, the probability of exposure to natural radiation due to altitude is increasing due to the increase in flight time. Cosmic-ray penetrates the Earth's magnetic field belt Van Allen, which is located at an altitude of 400 km to 1200 km. Most cosmic rays are blocked at Van Allen belt. However, cosmic-ray could be not completely blocked, and a small amount of cosmic-ray affects the earth. In general, if the altitude was increased by 100m, the natural exposure dose increased by 0.03 mSv on the Earth. In this study, I tried to minimize the exposure to natural radiation in airplanes when boarding airplanes. Especially, I was aimed to minimize radiation exposure by protecting the highly sensitive thyroid gland among human organs. According to the results of the study, the designed shielding handkerchief was able to shield cosmic natural radiation dose by more than 70%. In conclusion, the application of the shielding handkerchief made in this study can be effectively shield natural radiation.

Effects of Oral Administrated Thyroid Hormone ($T_3$) on Physiological Condition, Growth and Survival Rate of Juvenile Rockfish (Sebastes schlegeli) (외인성 갑상선호르몬 ($T_3$)의 경구투여가 조피볼락 (Sebastes schlegeli) 치어의 생리적 상태, 성장 및 생존에 미치는 영향)

  • KANG Duck-Young;CHANG Young Jin;KIM Yoon;MYOUNG Jeong-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.588-593
    • /
    • 2001
  • Rockfish (Sebastes schlegeli) juveniles were fed with the diets containing 0 (control and sham), 5, 10 and 15 ppm of 3,5,3'-triiodo-L-thyronine ($T_3$) for 50 days to assess the effect of the hormone on the change of physiological condition, growth and survival rate, fish were fed the commercial diet by hand to satiation 2 times per day. After 50 days, food intake, feed efficiency, thyroid cell height (TCH), abnormality, proximate body composition, growth, condition factor and survival rate were also examined. The food intake and the feed efficiency of S. schlegeli fed with diet containing 10 ppm of $T_3$ was significantly higher than those of fishes fed with the other diets. On the final day of experiment, atrophy of thyroid gland was observed in fish administered with 10 and 15 ppm of $T_3$. $T_3$increased slightly the abnormality according to the increase of $T_3$dose. The whole body proximate analyses indicated that the fishes administrated with 15 ppm of $T_3$ were the highest in protein content and were the lowest in lipid, but in ash content were there a significant effects of $T_3$. The growth of S. schlegeli fed with a diet containing 10 ppm of $T_3$ was significantly higher than that of control. The condition factor was not related to administered $T_3$ content. $T_3$ slightly improved the survival rate of juvenile S. schlegeli, and the survival rate of fish administered with 10 ppm was significantly higher than that of sham-control but was lower than that of control.

  • PDF

Mouse Submandibular Gland Cells: Isolation and Establishment of Culture Condition En vitro (마우스의 악하선 세포의 분리 및 배양조건 확립)

  • 소준노;박호원;장선일;이금영;이원구
    • The Korean Journal of Zoology
    • /
    • v.34 no.2
    • /
    • pp.148-158
    • /
    • 1991
  • The purpose of this research was to establish the culture condition for dissociated submandibu -lar gland (SG) cells. After trypsin digestion of SG from 3-4 weeks old mice, dissociated cells were cultured in 1OO/o fetal bovine serum-Dulbecco's modified Eagle's medium (FBS-DME) or 0.5-2% low protein serum replacement-DME (LPSR-DME) on plastic surface to form monolayer. The effects of FBS, LPSR and hormones on the growth and function of cultured SG cells were examined. SG cells dissociated by enzyme were successfully cultured and were characterized as epithelial-like cells by light and electron microscope. The maximal DNA synthesis of cultured SG cells was achieved by DME containing 5-10% FBS. The same results were obtained when the effects of LPSR on cell proliferation were examined up to a LPSR concentration of 2%. SG cells cultured in 20/o LPSR-DME expressed a population doubling time of 42.5 hrs and a saturation density of 1.2 $\times$10 5cell/cm$^2$. Dihydrotestosterone (DHT) in medium did not influence on the DNA synthesis of the cultured SG cells, but stimulated protein synthesis of the SG cells. Thyroxine (T4) stimulated protein synthesis of the SCI cells markedly in a dose-dependent fashion. EGF secretion by the cultured SG cells increased significandy by DHT and or T4 trearment. This finding indicated that secretion of EGF by the SG cells was under the control of the hormones such as androgen and thyroid hormones. It seems to be that the culture condition described here can be used as a useful tool for further research on the SCI cells.

  • PDF

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Effects of Exogenous Thyroid Hormone $(T_3)$ on Skeletal Development and Physiological Conditions of Juvenile Black Seabream (Acanthopagrus schlegeli) (감성돔(Acanthopagrus schlegeli) 치어의 골격발달 및 생리적 조건에 미치는 외인성 갑상선호르몬$(T_3)$의 영향)

  • KANG Duk-Young;CHANG Young Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.305-312
    • /
    • 1997
  • Juveniles of black seabream, Acanthopagrus schlegeli were fed with the diets containing 0, 10, 20, 50 and 100 ppm of 3,5,3'-triiodo-1-thyronine $(T_3)$ respectively to assess the effect of this hormone on skeletal development and the change of physiological conditions for 50 days. $(T_3)$ treatment lasted for initial 40 days. Fish were fed the prescribed diet by hand to satiation in $2\~4$ times per day. After an initial 40 days period, skeletal development and abnormality were examined, and after a 50 days period, food intake, hepatosomatic index (HSI), thyroid cell height (TCH) and body proximate composition were also examined. Although toed intake was not different among 0, 10 and 20 ppm, the food intake of black seabream fed with the diets containing 50 and 100 ppm of $T_3$was significantly lower than those of 10 ppm. After the initial 40 days of $T_3$ administration, $T_3$ increased the relative growth of operculum, head, caudal fin and pectoral fin to body length, resulting in severe morphological abnormalities at the highest dose. Black seabream treated with 50 and 100 ppm of $T_3$ had abnormal shapes such as lordosis and opercular curl. The HSI parameters were reversely correlation with the dietary concentration of $T_3$. After the initial 40 days of this experiment, atrophy of thyroid gland was observed in fish administered with 50 and 100 ppm of $T_3$. On the 50th day of this experiment, atrophy of thyroid gland was observed only in the group administered with 100 ppm of $T_3$, and no difference was observed on TCH among the rest fours of experimental groups. At the end of the experiment the whore body proximate analyses indicated that there were significant effects of $T_3$ level on moisture, protein, lipid and ash contents.

  • PDF

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF

A Study on the Secondary Carcinogenesis Rate of Vestibular Schwannoma Disease using Glass Dosimeter (유리선량계를 이용한 청신경초종 질환의 2차 발암률에 관한 연구)

  • Joo-Ah Lee;Gi-Hong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.243-248
    • /
    • 2023
  • This study aims to analyze the secondary carcinogenesis rate caused by exposure of organs at risk of damage using a glass dosimeter during radiosurgery in vestibular schwannoma disease. Using a pediatric phantom of human tissue equivalent material, the volume of the tumor was set to a total of three volumes: 0.506 cm3, 1.008 cm3, and 2.032 cm3, and a radiosurgery plan was established with an average dose of 18.4 ± 3.4 Gy. After mounting the human body phantom on the table of surgical equipment, glass dosimeters were placed on the right eye, left eye, thyroid gland, thymus, right lung, and left lung to measure the exposure dose, respectively. In this study, the incidence of secondary cancer due to exposure to damaged organs during gamma knife radiosurgery in vestibular schwannoma disease with the largest tumor volume of 2.032 cm3 was measured with a glass dosimeter. This study studies the risk of secondary radiation exposure dose that can occur during stereotactic radiosurgery, and it is considered that it will be used as basic data in the field of radiation damage related to the stochastic effect of radiation in the future.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

Image Quality Analysis when applying DLIR Reconstruction Techniques in NECT CT (NECT CT에서 DLIR 재구성기법 적용 시 화질분석)

  • Yoon, Joon;Kim, Hyeon-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.387-394
    • /
    • 2022
  • 120 kVp FBP reconstruction image standard by using raw data after scanning by changing tube voltage among the NECK CT protocols that are broad applied in clinical practice using a human phantom including thyroid gland The usefulness of the DLIR reconstruction technique was investigated. As a result, CTDIvol decreased when the DLIR reconstruction technique was applied, and in particular, the image quality obtained under the same standard scanning conditions at a lower dose for ASIR-V and DLIR reconstruction was reached than when FBP was applied at the same kVp In addition, as a result of SNR and CNR analysis, the DLIR reconstructed image was analyzed with high SNR and CNR values, and SSIM analysis, the SSIM index of the 100 kVp, DLIR reconstructed image was measured to be close to 1, and it was analyzed that the similarity of the reconstructed image to the original image was high (p>0.05). If the results of this study are used to supplement clinical image evaluation and further develop an algorithm applicable to various anatomical structures, it is thought that it will be useful for clinical application as it is possible to maintain the image quality while lowering the examination dose.

Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer (성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가)

  • Kim, Woo Chul;Min, Chul Kee;Lee, Suk;Choi, Sang Hyoun;Cho, Kwang Hwan;Jung, Jae Hong;Kim, Eun Seog;Yeo, Seung-Gu;Kwon, Soo-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.