Investigations of the External Dose Rate (${\mu}Sv/h$), the Residual Activity (mCi) and the Excretion Rate (%) of Thyroid Cancer Patients Hospitalized for 3700 MBq (100 mCi) $^{131}I$ Radioiodine Treatment ($^{131}I$ 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(${\mu}Sv/h$), 잔류량(mCi), 배설률(%) 측정)

  • Bae, Gi-Han;Kim, Hwa-Joong;Choi, Jae-Jin;Lee, Won-Guk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2009
  • Purpose: As Korean nuclear law doesn't have any clear guideline about the dose and the external dose rate(uSv/h) requiring hospitalization in radioactive iodine treated patients, the patients are discharged when they meet the guideline of IAEA Basic Safety Standards(BSS). We measured external dose rate(${\mu}Sv/h$) of inpatient underwent 3700MBq (100 mCi) $^{131}I$ radioiodine treatment and considering external dose rate(${\mu}Sv/h$), residual activity(mCi) and excretion rate(%) we found the time for RA to be lowered from 3700MBq (100 mCi) to 1110 MBq (30 mCi) to give reference to set a guideline for discharge. Materials and Methods: Forty-two patients underwent thyroidectomy and scheduled for radioiodine treatment, who received 3700MBq (100 mCi) of $^{131}I$ orally and had no renal disease were examined. After 1, 2, 4, 8, and 20, 24, 40 hours iodine uptake and before/after the urination, the external dose rate(${\mu}Sv/h$) measured using FH40G-L(Thermo Fisher Scientific Inc., MA) at a distance and a height of 1 m for 20 sec on the average. Results and Conclusions: At 20 hours, the external dose rate was decreased to $49{\pm}13\;{\mu}Sv$/h, namely, 78% of administrated radioactivity was excreted and 814 MBq (30 mCi) was residual, and it met the accepted limit for discharge of (IAEA, BSS) under 1110 MBq (30 mCi) (1 m at 66 uSv/h).

  • PDF

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Effects of Exogenous Thyroid Hormone $(T_3)$ on Skeletal Development and Physiological Conditions of Juvenile Black Seabream (Acanthopagrus schlegeli) (감성돔(Acanthopagrus schlegeli) 치어의 골격발달 및 생리적 조건에 미치는 외인성 갑상선호르몬$(T_3)$의 영향)

  • KANG Duk-Young;CHANG Young Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.305-312
    • /
    • 1997
  • Juveniles of black seabream, Acanthopagrus schlegeli were fed with the diets containing 0, 10, 20, 50 and 100 ppm of 3,5,3'-triiodo-1-thyronine $(T_3)$ respectively to assess the effect of this hormone on skeletal development and the change of physiological conditions for 50 days. $(T_3)$ treatment lasted for initial 40 days. Fish were fed the prescribed diet by hand to satiation in $2\~4$ times per day. After an initial 40 days period, skeletal development and abnormality were examined, and after a 50 days period, food intake, hepatosomatic index (HSI), thyroid cell height (TCH) and body proximate composition were also examined. Although toed intake was not different among 0, 10 and 20 ppm, the food intake of black seabream fed with the diets containing 50 and 100 ppm of $T_3$was significantly lower than those of 10 ppm. After the initial 40 days of $T_3$ administration, $T_3$ increased the relative growth of operculum, head, caudal fin and pectoral fin to body length, resulting in severe morphological abnormalities at the highest dose. Black seabream treated with 50 and 100 ppm of $T_3$ had abnormal shapes such as lordosis and opercular curl. The HSI parameters were reversely correlation with the dietary concentration of $T_3$. After the initial 40 days of this experiment, atrophy of thyroid gland was observed in fish administered with 50 and 100 ppm of $T_3$. On the 50th day of this experiment, atrophy of thyroid gland was observed only in the group administered with 100 ppm of $T_3$, and no difference was observed on TCH among the rest fours of experimental groups. At the end of the experiment the whore body proximate analyses indicated that there were significant effects of $T_3$ level on moisture, protein, lipid and ash contents.

  • PDF

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

A Study on the Secondary Carcinogenesis Rate of Vestibular Schwannoma Disease using Glass Dosimeter (유리선량계를 이용한 청신경초종 질환의 2차 발암률에 관한 연구)

  • Joo-Ah Lee;Gi-Hong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.243-248
    • /
    • 2023
  • This study aims to analyze the secondary carcinogenesis rate caused by exposure of organs at risk of damage using a glass dosimeter during radiosurgery in vestibular schwannoma disease. Using a pediatric phantom of human tissue equivalent material, the volume of the tumor was set to a total of three volumes: 0.506 cm3, 1.008 cm3, and 2.032 cm3, and a radiosurgery plan was established with an average dose of 18.4 ± 3.4 Gy. After mounting the human body phantom on the table of surgical equipment, glass dosimeters were placed on the right eye, left eye, thyroid gland, thymus, right lung, and left lung to measure the exposure dose, respectively. In this study, the incidence of secondary cancer due to exposure to damaged organs during gamma knife radiosurgery in vestibular schwannoma disease with the largest tumor volume of 2.032 cm3 was measured with a glass dosimeter. This study studies the risk of secondary radiation exposure dose that can occur during stereotactic radiosurgery, and it is considered that it will be used as basic data in the field of radiation damage related to the stochastic effect of radiation in the future.

Head and neck extra nodal NHL (HNENL) - Treatment Outcome and Pattern of failure - A Single Institution Experience

  • Giridhar, Prashanth;Mallick, Supriya;Bhasker, Suman;Pathy, Sushmita;Mohanti, Bidhu Kalyan;Biswas, Ahitagni;Sharma, Atul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6267-6272
    • /
    • 2015
  • Background: Extra nodal lymphoma (ENL) constitutes about 33 % of all non-Hodgkin's lymphoma. 18-28% develops in the head and neck region. A multimodality treatment with multi-agent chemotherapy (CT) and radiotherapy (RT) is considered optimum. Materials and Methods: We retrieved the treatment charts of patients of HNENL treated in our institute from 2001-2012. The charts were reviewed and the demographic, treatment details and outcome of HNENL patients were retrieved using predesigned pro-forma. Results: We retrieved data of 75consecutive patients HNENL. Median age was 47years (Range: 8-76 years). Of the 75 patients 51 were male and 24 were female. 55patients were evaluable. The patient and tumor characteristics are summarized in Table 1. All patients were staged comprehensively with contrast enhanced computed tomography of head, neck, thorax, abdomen, pelvis and bone marrow aspiration and biopsy 66 patients received a combination multi-agent CT with CHOP being the commonest regimen. 42 patients received 4 or lesser number of cycles of chemotherapy whereas 24received more than 4 cycles chemotherapy. Post radiotherapy, 41 out of 42 patients had a complete response at 3 months. Only 21patients had a complete response after chemotherapy. All patients received radiation (mostly involved field radiation) as a part of the treatment. The median radiation dose was 45 Gray (Range: 36 Gray-50 Gray). The radiation was planned by 2D fluoro simulation based technique in 37cases and by 3 Dimensional conformal radiation therapy (3DCRT) in 36 cases. Two patients were planned by the intensity modulated radiation therapy (IMRT) technique. IMRT was planned for one thyroid and one nasal cavity primary. 5 patients experienced relapse after a median follow up of 19 months. The median survival was not reached. The estimated two and three year survival were 92.9% (95%CI- 68.6- 95.35) and 88% (95%CI- 60.82 - 92.66) respectively. Univariate analysis revealed higher stage and poorer baseline performance status to be significantly associated with worse progression free survival. 5 patients progressed (relapse or primary disease progression) after treatment. Of the 5 patients, two patients were primary orbital NHL, two patients had NHL nasal cavity and one was NHL thyroid. Conclusions: Combined modality treatment in HNENL confers excellent disease control with acceptable side effects.

TSH Response to the Intravenous Administation of Synthetic TRH in Various Thyroid Diseases (각종(各種) 갑상선질환(甲狀腺疾患)에서 합성(合成) TRH 정주후(靜注後) 혈중(血中) TSH 변동(變動)에 관(關)한 연구(硏究))

  • Choi, Sung-Jae;Kim, Kwang-Won;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 1980
  • Serum TSH levels were measured by radioimmunoassay before and after intravenous administration of synthetic thyrotropin-releasing hormone (TRH) to 15 normal subjects and 55 patients with primary thyroid disease (14 patients with euthyroidism, 24 patients with thyrotoxicosis and 17 patients with hypothyroidism) to evaluate pituitary TSH reserve and its diagnostic availability. The observed results were as follows. 1. In normal subjects, serum TSH responses to synthetic TRH were $3.2{\pm}1.0$ at 0min (baseline TSH level), $8.0{\pm}4.0$ at 10min, $11.7{\pm}5.0$ at 20min, $13.7{\pm}7.1$ at 30min, $9.7{\pm}5.0$ at 60min., $5.2{\pm}2.0$ at 120min. and $3.6{\pm}0.4{\mu}U/ml$ at 180 min. Serum TSH peaked at $20{\sim}30$ minutes and returned nearly to baseline at 180minutes. 2. In euthyroid group, serum TSH responses to synthetic TRH were $3.3{\pm}1.6$ at 0min, $8.6{\pm}8.0$ at 10min, $10.9{\pm}8.5$ at 20min, $12.5{\pm}8.4$ at 30min, $9.0{\pm}5.9$ at 60min, $5.6{\pm}2.6$ at 120min and $3.5{\pm}1.3{\mu}U/ml$ at 180min. No significant difference revealed between euthyroid group and normal subjects (p>0.05). 3. In hyperthyroid group, serum TSH responses to synthetic TRH were $1.5{\pm}0.6$ at 0min, $2.2{\pm}0.8$ at 10min., $2.3{\pm}1.0$ at 20min., $2.4{\pm}1.5$ at 30min., $2.1{\pm}1.1$ at 60min., $1.9{\pm}0.2$ at 120min. and $1.5{\pm}0.8{\mu}U/ml$ at 180min., No response to TRH showed. 4. In hypothyroid group, mean values of serum TSH response to synthetic TRH were 42.0 at 0min., 60.6 at 10min., 124.8 at 20min., 123.0 at 30min., 101.6 at 60min., 64.3 at 120min. and $15.5{\mu}U/ml$ at 180 min., Patients with primary hypothyroidism showed an exaggerated TSH response to synthetic TRH despite their high basal TSH. 5. Side effects attending synthetic TRH administration were transient nausea (59.0%), desire to micturate (59.0%), feeling of flushing(19.7%), dizziness (45.9%), metallic taste (9.8%) and headache (19.7%). Any side effect didn't show in 16.4%. These symptoms began almost immediately after TRH intravenous injection and lasted several minutes, and not related to dose or response in the person experiencing it.

  • PDF

Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer (성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가)

  • Kim, Woo Chul;Min, Chul Kee;Lee, Suk;Choi, Sang Hyoun;Cho, Kwang Hwan;Jung, Jae Hong;Kim, Eun Seog;Yeo, Seung-Gu;Kwon, Soo-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.