Song, Han Gyeol;Yun, In Sik;Lee, Won Jai;Lew, Dae Hyun;Rah, Dong Kyun
Archives of Plastic Surgery
/
제40권4호
/
pp.353-358
/
2013
Background Robots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction. Methods We investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated. Results Among five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes), and complications including flap necrosis, hematoma, and wound dehiscence did not occur. Conclusions This study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.
We established a model to calculate radioactive waste from sewage disposal tank of hospitals to optimize the number of patients receiving inpatient radioiodine therapy within the safety guideline in our country. According to this model and calculation of radioactivity concentration using the number of patients per week, the treatment dose of radioiodine, the capacity and the number of sewage tanks and the daily amount of water waste per patient, estimated concentration of radioactivity in sewage waste upon disposal from disposal tanks after longterm retention were within the safety guideline (30 Bq/L) in all the hospitals examined. In addition to the fact that we could increase the number of patients in two thirds of hospitals, we found that the daily amount of waste water was the most important variable to allow the increase of the number of patients within the safety margin of disposed radioactivity. We propose that saving the water amount be led to increase the number of patients and they allow two patients in an already furnished hospital inpatient room to meet the increasing need of inpatient radioiodine treatment for thyroid cancer.
Objective and Background: Laryngeal stroboscope is an useful equipment in evaluation of vocal cord vibration and in early detection of mucosal lesion including invasive cancer of the vocal cord. Recently Lee et al. (2006) developed portable stroboscope using voice as synchronization signal. It has been frequently impaired ability to synchronize the flashes even in normal female. Authors tried to investigate various methods including vibration pick-up, microphone, laryngeal microphone, and contact microphone for development of simple and accurate method like electroglottograph signal. The purpose of this study was to estimate wheher the vibration pick-up is available and is consistent with the signal of EGG. Subjects and Methods: Authors compared the signals between EGG and noncontact method such as voice, contact methods including vibration pick-up, laryngeal microphone, and contact microphone in normal twenty adults (male 10 and female 10). The number of peak in one cycle was compared with the number of the peak in EGG, and the percent of phase difference in the peak was compared with EGG Also, authors tried to investigate which site of vibration pick-up was most effective for synchronization of stobo flashes. Three site including anterior neck below the cricoid cartilage, thyroid ala, and suprahyoid region were analysed. Results: Among various methods for synchronization of strobo flashes, vibration pick-up was most effective method in peak detection. And anterior neck below cricoid cartilage was the most available site of the vibration pick-up. Conclusion: Authors suggest that vibration pick-up is most available and effective method for synchronization of strobo flashes.
갑상선암 진단 방사성의약품인 $^{123}I$ 생산을 목적으로 한 가스타겟챔버를 개발하고 MCNPX를 이용해 30MeV 빔에너지 가 가스타겟챔버에 어떻게 들어가는지와 들어갔을 경우의 $^{124}Xe$와 핵반응은 어떻게 발생하는지를 모델링하였다. 빔에너지 가 확산되어 가스타겟챔버 내경에 맞아 에너지 손실이 생긴다. 그것은 즉 손실된 에너지가 열로 바뀜으로 타겟챔버가 변형이 일어나기 않게 냉각수를 이용한다. 쿨링시스템도 타겟챔버를 효율적으로 냉각하기위해 냉각수라인을 나선형으로 설계하였다. KIRAMS에서 보유하고 있는 사이크로트론 C30을 이용하여 30MeV 에너지에 100A 빔을 조사해 $^{124}Xe(p,2n)$, $^{124}Xe(p,n)$, $^{124}Xe(p,pn)$ 각각의 핵반응이 일어나는걸 알 수 있었고 생산량을 예측 할 수 있었다.
Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.
Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.
It has been demonstrated that APPL1 (adaptor protein, phosphotyrosine interacting with PH domain and leucine zipper 1) is involved in the regulation of several growth-related signaling pathways and thus closely associated with the development and progression of some cancers. Diallyl trisulfide (DAT), a garlic-derived bioactive compound, exerts selective cytotoxicity to various human cancer cells through interfering with pro-survival signaling pathways. However, whether and how DAT affects survival of human hepatocellular carcinoma (HCC) cells remain unclear. Herein, we tested the hypothesis of the involvement of APPL1 in DAT-induced cytotoxicity in HCC HepG2 cells. We found that Lys 63 (K63)-linked polyubiquitination of APPL1 was significantly decreased whereas phosphorylation of APPL1 at serine residues remained unchanged in DAT-treated HepG2 cells. Compared with wild-type APPL1, overexpression of APPL1 K63R mutant dramatically increased cell apoptosis and mitigated cell survival, along with a reduction of phosphorylation of STAT3, Akt, and Erk1/2. In addition, DAT administration markedly reduced protein levels of intracellular TNF receptor-associated factor 6 (TRAF6). Genetic inhibition of TRAF6 decreased K63-linked polyubiquitination of APPL1. Moreover, the cytotoxicity impacts of DAT on HepG2 cells were greatly attenuated by overexpression of wild-type APPL1. Taken together, these results suggest that APPL1 polyubiquitination probably mediates the inhibitory effects of DAT on survival of HepG2 cells by modulating STAT3, Akt, and Erk1/2 pathways.
The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.
연구배경 :핵사고시 가장 중요한 유출방사성핵종의 하나이며, 갑상선암 및 갑상선 기능항진증 치료에 없어서는 안되는 치료제인 방사성옥소($^{131}I$)는 과량 투여시 백혈병 또는 유전이상을 나타낼 것으로 추측되고 있으나, 이에 대해서는 아직 논란의 여지가 있다. 방법 : 실험군은 방사성옥소를 투여하지 않고 위장수술만을 시행한 대조군과, 갑상선 기능항진증의 치료용량인 10mCi/60Kg(0.17mCi/Kg)을 투여하는 군, 갑상선암의 치료용량인 100 mCi/60 Kg (1.67 mCi/Kg)을 투여하는군, 그리고 골수억제 등의 부작용 때문에 치료를 중단하게 되는 1000 mCi/60 Kg(16.67 mCi/Kg)를 투여하는 군으로 나누어 실험을 시행하였다. 각 군은 생후 6주(30g)전후의 생쥐 10마리로 구성되었으며, 방사성옥소는 복강에 투여하였다. 투여 1일 및 3일 후 생쥐를 희생시켜 골수를 채취하고, 이를 대상으로 미소핵검사를 시행하였다. 미소핵은 골수세포 중핵이 없는 정염성 및 다염성적헐구에서 관찰하며, 1000개의 세포 중 미소핵이 나타난 세포수를 %로 표시하였다. 결과 : 다염성 적혈구 (괄호안은 정염성 적혈구)에서의 미소핵 발현은 대조군의 경우 1일째 $0.25{\pm}0.07$ ($0.23{\pm}0.07$)%, 3일째 $0.24{\pm}0.07$ ($0.21{\pm}0.07$)%, 치료용량의 방사성옥소를 투여한 군 중 0.17 mCi/Kg을 투여한 군에서는 1일째 $0.27{\pm}0.1$ ($0.23{\pm}0.09$)%, 3일째 $0.28{\pm}0.07$ ($0.25{\pm}0.06$)%, 1.67 mCi/Kg을 투여한 군에서는 1일째 $0.29{\pm}0.08$ ($0.26{\pm}0.09$)%, 3일째 $0.31{\pm}0.05$ ($0.29{\pm}0.06$)%, 16.67mCi/Kg를 투여하는 군에서는 1일째 $0.32{\pm}0.06$ ($0.25{\pm}0.09$)%, 3일째 $0.33{\pm}0.08$ ($0.3{\pm}0.06$)%를 보였다. 투여한 방사성옥소의 양이 많을수록 미소핵 빈도수가 증가하는 경향을 보였으나, 각 군간에 통계학적으로 유의한 차이는 없었다(p>0.05). 결론 : 임상적으로 치료를 중단하게 되는 1000mCi/60 Kg(16.67 mCi/Kg)를 투여한 군에서도 생쥐 골수내 미소핵이 발현되지 않는 것으로 보아, 방사성옥소는 비교적 안심하고 치료에 사용할 수 있는 제제로 사료되었다.
The purpose of this study is to provide some basic data for the direction of nursing education and practice to prevent nursing malpractice as investgating perception of the nurse on the nursing malpractice and its case. Data were collected from 450 nurse working in four general hospitals which were located in Chonbuk province from November 9 to 21, 1998 through questionnare. The structured instruments developed by the reseacher were used for collecting data. The Results were as follows: 1) As for the cognition of the nursing malpractice case, the transfusion accident was 37.3%, the side-effects of KCL injection(19.3%), hymen rupture by uterus cancer test, the side-effects of aminophyllin injections on dyspnea patient and the others were 10% below. 2) With regard to the channel of the perception of the nursing malpractice case, mass-communication was taken first and followed through by neighbors, In-service education, school education, continuing education 3) As for the direct${\cdot}$indirect experience of the nursing malpractice case, transfusion accident was 51.3%, the fall of NPO patient after an operation 40.1%, the side-effect of KCL injection 32.5%, suicide of the psychiatric patient 32.5%, and the others were 30% below. 4) The possibility of nursing malpractice case was an average 2.57(${\pm}$0.91) and the highest was the fall of the NPO patient after an operation. 5) The perception on the responsibility of the nursing malpractice in its case was indicated as a joint-fault in ten nursing malpractice instances. As compared to the real decision, nurse's perception of the responsibility in the fall of the NPO patient after an operation, the side-effect of KCL injection, the tracheal edema of the patient who had a thyroid operation, the suicide of psychiatric patient, the hymen rupture by uterus cancer test accorded real decisions. But the other cases were different from the real decisions. These cases were perceived as ones of joint fault even in cases determined as Dr's single fault cases or those in which both doctor and nurse were declared free of fault. 6) Knowledge levels of the nursing malpractice, school education and In-service education were perceived as low but anxiety levels of the malpractice were high. 7) With regard to the countmeasure of the hospital after nursing malpractice, the rate answered as "the practice settled the accident temporarily and forced the person in charge to be punished" was highest. In conclusion, the level of the cognition of the clinical nurse on nursing malpractice cases was low. As nurses' perception on the responsibility of the nursing malpractice case was compared to the real decision, there was a difference in five cases out of the ten cases.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.