• 제목/요약/키워드: thrombus

Search Result 351, Processing Time 0.033 seconds

Comparison of symptomatic and asymptomatic pulmonary embolism in proximal deep vein thrombosis (근위부 심부정맥 혈전증에서 유증상 폐색전증과 무증상 폐색전증의 비교)

  • Kim, Dong Hun;Seo, Young Woo;Kim, Gyun Moo;Ko, Seung Hyun;Jang, Jae Seok;Jang, Tae Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.231-237
    • /
    • 2017
  • Background: Deep vein thrombosis (DVT) and pulmonary embolism (PE) are conditions with significant morbidity and mortality. Proximal DVT has a significant association with PE and possible fatal outcomes. Traditionally, PE is subdivided into symptomatic PE and asymptomatic PE, which have different treatments, preventions and prognoses. The growing utilization of computed tomography pulmonary angiography has led to increased detection of PE in DVT patients. This study examined the clinical characteristics and compared symptomatic PE and asymptomatic PE following proximal DVT. Methods: The medical records of 258 DVT inpatients from July, 2012 to June, 2015 were reviewed retrospectively. After excluding the patients who did not performed PE evaluation and were not diagnosed with PE, 95 patients diagnosed with PE following proximal DVT were enrolled in this study. They were divided into the symptomatic PE group and asymptomatic PE group. Results: The body weight, body mass index, thrombus size, thrombus length and location were similar in the two groups. The symptomatic PE following proximal DVT group showed an older age, higher incidence of emergency department access (85.0% vs. 38.7%, p<0.001) and preceding infection (25.0% vs. 1.3%, p<0.001) as well as a higher incidence of immobilization (45.0% vs 13.3%, p=0.016). In the multivariate logistic regression study, preceding infection and emergency department access showed significant association with symptomatic PE. Conclusion: In proximal DVT inpatients, symptomatic PE was associated with emergency department access and preceding infection. The possibility of a symptomatic PE event should be considered in proximal DVT patients, especially those who were admitted through the emergency department and had preceding infection.

Direct Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Objective : Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filters during CAS. Methods : A total of 107 patients underwent CAS with use of a distal protection filter. Angiographic carotid plaque surface morphology was classified as smooth, irregular, and ulcerated. To determine predictable factors of filling defect in the protection filters, 11 variables were retrospectively analyzed which might influence filling defect in the protection filters during CAS. Results : Filling defects during CAS were presented in the 33 cerebral protection filters. In multivariate analysis, angiographic ulceration [odds ratio (OR), 6.60; 95% confidence interval (CI) : 2.24, 19.4; p=0.001], higher stenosis degree (OR, 1.06; 95% CI : 1.00, 1.12; p=0.039), and coexistent thrombus (OR, 7.58; 95% CI : 1.69, 34.05; p=0.08) were highly associated with filling defect in the cerebral protection devices during CAS. Among several variables, angiographic surface ulceration was the only significant factor associated with flow stagnation during CAS (OR, 4.11; 95% CI : 1.33, 12.72; p=0.014). Conclusion : Plaque surface morphology on carotid angiography can be a highly sensitive marker of plaque instability during CAS. The independent risk factors for filling defect in the filter devices during CAS were plaque ulceration, stenosis degree, and coexistent thrombus.

Open Heart Surgery 600 Cases for 5 Years (5년간 개심술 600예에 관한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.404-420
    • /
    • 1991
  • Surgical treatment of congenital and acquired heart disease preceded the development of accurate techniques for diagnosis, heart lung machine and cardiopulmonary bypass, intraoperative myocardial protection, operative techniques and cardiac anesthesia. For 5 years from Sep. 1985 to Sep. 1990, six hundred cases of open heart surgeries [OHS] were performed in the department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. The results were summarized as follows. 1. The annual number of OHS[cases per year] was above 100 since 1987, and the increasing rate of cases was 23.5% per year since 1986. 2. Among the total 600 cases, there were 470 cases of congenital heart diseases and 130 cases of acquired. Age range of the congenital patients was 8 months to 44 years with the mean age of 10 years, and acquired patients was 16 to 56 years with the mean age of 36 years. 3. Among the 470 congenital anomalies, there were 429 cases of acyanotic and 41 cyanotic patients. Totally, VSD was 286 cases[60.6%], ASD 103 cases[21.9%], TOF 35 cases [7.4%], PS 20 cases [4.1%], ECD 12 cases [2.0%], Ebstein`s anomaly 3 cases [0.6%], Valsalva sinus rupture 3 cases [0.6%] and others. The appropriate one stage radical operations were applied to the all congenital cases with the result of 2.6% immediate postoperative hospital mortality rate. 4. Among the 130 acquired cases, there were 122 cases of valvular heart diseases, 6 of heart tumors [5 myxoma, one malignant histiocytoma], one of LA thrombus and one of annuloaortic ectasia. Cardiac tumors and LA thrombus were removed through the atrial septal approach. Bentall procedure was adopted to the annuloaortic ectasia case. AVR, MVR and TVA [DeVega procedure] were applied to 120 valve diseases, and there were also one of OMC and one of MVA[Jerome-Kay procedure]. 5. Among the 120 valve replacement cases, there were 87 of single valve replacement cases [AVR: 8, MVR: 79], 11 of double valve replacement [AVR+MVR: 11], 12 of MVR+TVR and 10 of MVR+AVR+TVA. The total number of implanted prosthetic valves were 141. In MVR, 45 of St. Jude Medical valves, 63 of Carpentier-Edward valves and 4 of Ionescu-Shiley valves were used. In AVR, 18 of St. Jude Medical valves and 11 of Carpentier-Edward valves were used. in MVR, 29mm and 31mm sized valves were used mostly and In AVR, 23mm sized valves were used mostly. 6. Postoperatively many kinds of complications were occurred. Among them, wound problems [30 cases], low output syndrome [29 cases], arrhythmia [20 cases], pleural effusion and pneumothorax [13 cases] were occurred frequently. The postoperative immediate hospital mortality was 3.0% in total [congenital 2.6%, acquired 4.6%].

  • PDF

The Experimental Study on Antithrombotic activities of Saegeumsan(瑞金散) (서금산(瑞金散)의 항혈전작용(抗血栓作用)에 대(對)한 실험적(實驗的) 연구(硏究))

  • Lee, Bo-ra;Kim, Eui-il;Lee, Jung-eun;Yoo, Dong-Youl
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • This study was performed to evaluate antithrombotic activities of Saegeumsan (瑞金散, SGS) which has effects of activating blood, removing thrombus. This study is designed to measure the effect which was given to blood flow rate through the regular volume of glass tube after the blood was diluted five times with ACD solution. Antithrombotic effect was calculated as a percentage of the experimental animal figure protected from the paralysis of hind legs or death of the mouse that is caused from the administration of platelet aggregation regent. We standardized the time when the experimental animals were incapable of functioning the hind legs more than 20 minutes or maintained trembling. Being classified one group of eight mice, each of them was divided into Normal, Control, and SGS. The normal group supplied a saline solution and the control group brought the dextran extravasated blood after an hour of administering the saline solution. Also, SGS was dissolved in $2m{\ell}$ saline solution and then we dosed it to the experimental mice with Oral Zonde one day before the experiment. After that, the mice were abstained from food. And then we gave a measured amount of it before an hour. Finally, it gave rise to dextran extravasated blood in the same way as the Control group. The results were obtained as follows, SGS significantly inhibited platelet aggregation induced by ADP and epinephrine when analyzed by the Sigmoid $E_{max}$ model in WinNonlin. $EC_{50}$ values of SGS were 4.61 mg/ml and 12.41 mg/ml for ADP and epinephrine respectively. SGS showed fibrinolytic activity insignificantly as compared with the control group. SGS increased blood flow rate significantly as compared with the control group in vitro. SGS inhibited pulmonary embolism induced by collagen and epinephrine(inhibitive rate is 37.5 %). SGS increased number of platelet and fibrinogen amount significantly, and shortened PT and APTT as compared with the control group in thrombus model induced by dextran. According to, SGS is effective antithrombotic activity from experimental result.

  • PDF

Efficacy of Combining Proximal Balloon Guiding Catheter and Distal Access Catheter in Thrombectomy with Stent Retriever for Anterior Circulation Ischemic Stroke

  • Kim, Sang Hwa;Choi, Jae Hyung;Kang, Myung Jin;Cha, Jae Kwan;Kim, Dae Hyun;Nah, Hyun Wook;Park, Hyun Seok;Kim, Sang Hyun;Huh, Jae Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.405-413
    • /
    • 2019
  • Objective : We evaluated efficacy of combining proximal balloon guiding catheter (antegrade flow arrest) and distal access catheter (aspiration at the site of occlusion) in thrombectomy for anterior circulation ischemic stroke. Methods : We retrospectively analyzed 116 patients who underwent mechanical thrombectomy with stent retriever. The patients were divided by the techniques adopted, the combined technique (proximal balloon guiding catheter and large bore distal access catheter) group (n=57, 49.1%) and the conventional (guiding catheter with stent retriever) technique group (n=59, 50.9%). We evaluated baseline characteristics (epidemiologic data, clinical and imaging characteristics) and procedure details (the number of retrieval attempts, procedure time), as well as angiographic (thrombolysis in cerebral infarction (TICI) score, distal thrombus migration) and clinical outcome (National Institutes of Health Stroke Scale at discharge, modified Rankin Scale [mRS] at 3 months) of them. Results : The number of retrieval attempts was lower (p=0.002) and the first-pass successful reperfusion rate was higher (56.1% vs. 28.8%; p=0.003) in the combined technique group. And the rate of final result of TICI score 3 was higher (68.4% vs. 28.8%; p<0.01) and distal thrombus migration rate was also lower (15.8% vs. 40.7%; p=0.021) in the combined technique group. Early strong neurologic improvement (improvement of National Institutes of Health Stroke Scale ${\geq}11$ or National Institutes of Health Stroke Scale ${\leq}1$ at discharge) rate (57.9% vs. 36.2%; p=0.02) and favorable clinical outcome (mRS at 3 months ${\leq}2$) rate (59.6% vs. 33.9%; p=0.005) were also better in the combined technique group. Conclusion : The combined technique needs lesser attempts, decreases distal migration, increases TICI 3 reperfusion and achieves better clinical outcomes.

Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging

  • Min Jae Cha;Don-Gwan An;Minsoo Kang;Hyue Mee Kim;Sang-Wook Kim;Iksung Cho;Joonhwa Hong;Hyewon Choi;Jee-Hyun Cho;Seung Yong Shin;Simon Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.647-659
    • /
    • 2023
  • Objective: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. Materials and Methods: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ($\left|\vec{V}\right|$ < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. Results: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surfaceand-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1, respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1, respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1, respectively) models. Conclusion: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.

Assessing Abdominal Aortic Aneurysm Progression by Using Perivascular Adipose Tissue Attenuation on Computed Tomography Angiography

  • Shuai Zhang;Hui Gu;Na Chang;Sha Li;Tianqi Xu;Menghan Liu;Ximing Wang
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.974-982
    • /
    • 2023
  • Objective: Recent studies have highlighted the active and potential role of perivascular adipose tissue (PVAT) in atherosclerosis and aneurysm progression, respectively. This study explored the link between PVAT attenuation and abdominal aortic aneurysm (AAA) progression using computed tomography angiography (CTA). Materials and Methods: This multicenter retrospective study analyzed patients with AAA who underwent CTA at baseline and follow-up between March 2015 and July 2022. The following parameters were obtained: maximum diameter and total volume of the AAA, presence or absence of intraluminal thrombus (ILT), maximum diameter and volume of the ILT, and PVAT attenuation of the aortic aneurysm at baseline CTA. PVAT attenuation was divided into high (> -73.4 Hounsfield units [HU]) and low (≤ -73.4 HU). Patients who had or did not have AAA progression during the follow-up, defined as an increase in the aneurysm volume > 10 mL from baseline, were identified. Kaplan-Meier and multivariable Cox regression analyses were used to investigate the association between PVAT attenuation and AAA progression. Results: Our study included 167 participants (148 males; median age: 70.0 years; interquartile range: 63.0-76.0 years), of which 145 (86.8%) were diagnosed with AAA accompanied by ILT. Over a median period of 11.3 months (range: 6.0-85.0 months), AAA progression was observed in 67 patients (40.1%). Multivariable Cox regression analysis indicated that high baseline PVAT attenuation (adjusted hazard ratio [aHR] = 2.23; 95% confidence interval [CI], 1.16-4.32; P = 0.017) was independently associated with AAA progression. This association was demonstrated within the patients of AAA with ILT subcohort, where a high baseline PVAT attenuation (aHR = 2.23; 95% CI, 1.08-4.60; P = 0.030) was consistently independently associated with AAA progression. Conclusion: Elevated PVAT attenuation is independently associated with AAA progression, including patients of AAA with ILT, suggesting the potential of PVAT attenuation as a predictive imaging marker for AAA expansion.

3D Visualization System of Blood Flow Reconstructed using Curvature Estimation (곡률 추정을 이용하여 재건된 혈류의 3차원 가시화 시스템)

  • Kwon, Oh-Seo;Yoon, Joseph;Kim, Young-Bong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.224-232
    • /
    • 2016
  • The methodology to visualize the shape of blood vessel and its blood flow have been attracting as a very interesting problem to forecast and examinate a disease in thrombus precursor protein. May previous visualization researches have been appeared for designing the blood vessel and also modeling the blood flow using a doppler imaging technique which is one of nondestructive testing techniques. General visualization methods are to depict the blood flow obtained from doppler effects with fragmentary stream lines and also visualize the blood flow model using volume rendering. However, these visualizeation techniques have the disadvantage which a set of small line segments does not give the overall observation of blood flows. Therefore, we propose a visualization system which reconstruct the continuity of the blood flow obtained from doppler effects and also visualize the blood flow with the vector field of blood particles. This system will use doppler phase difference from medical equipments such as OCT with low penetration and reconstruct the blood flow by the curvature estimation from vector field of each blood particle.

Alternative Mechanism of Aspirin in Anti-Thrombotic Therapy: Inhibition of Thrombin Activatable Fibrinolysis Inhibitor

  • An, Seong-Soo A.;Greenfield, Robert S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.3048-3054
    • /
    • 2012
  • The use of aspirin is widely recommended for the prevention of heart attacks owing to its ability to inhibit platelet activation by irreversibly blocking cyclooxygenase 1. However, aspirin also affects the fibrinolytic and hemostatic pathways by mechanisms that are not well understood, causing severe hemorrhagic complications. Here, we investigated the ability of aspirin and aspirin metabolites to inhibit thrombin-activatable fibrinolysis inhibitor (TAFI), the major inhibitor of plasma fibrinolysis. TAFI is activated via proteolytic cleavage by the thrombin-thrombomodulin complex to TAFIa, a carboxypeptidase B-like enzyme. TAFIa modulates fibrinolysis by removing the C-terminal arginine and lysine residues from partially degraded fibrin, which in turn inhibits the binding of plasminogen to fibrin clots. Aspirin and its major metabolites, salicylic acid, gentisic acid, and salicyluric acid, inhibit TAFIa carboxypeptidase activity. Salicyluric acid effectively blocks activation of TAFI by thrombin-thrombomodulin; however, salicylates do not inhibit carboxypeptidase N or pancreatic carboxypeptidase B. Aspirin and other salicylates accelerated the dissolution of fibrin clots and reduced thrombus formation in an in vitro model of fibrinolysis. Inhibition of TAFI represents a novel hemostatic mechanism that contributes to aspirin's therapy-associated antithrombotic activity and hemorrhagic complications.

A Study of the Acoustical Properties of the Mechanical Heart Valve Using MUSIC (MUSIC을 이용한 기계식 심장 판막의 음향 신호 특성 연구)

  • Yi S. W.;Choi M. J.;Min B. G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.131-134
    • /
    • 1999
  • This paper considers the acoustical characteristics of the mechanical valve employed in the Korean type Artificial Heart. $Bj\"{o}rk-Shiley$ tilting disc valve was chosen for the study and acoustic measurements were performed for the artificial heart operated in a mock circulation system as well as implanted to an animal as a Bi Ventricular Assist Device (BVAD). In the mock system, three different conditions of the valve were examined which were normal, damaged (torn off), pseudothrombus attached. Microphone measurements for the BVAD were carried out at a regular time interval for 5 days after the implantation operation. Of the recorded acoustic emissions from the artificial heart, click sounds mainly originated from the valves were further analyzed using Multiple Signal Classification (MUSIC) for estimating their spectral properties. It was shown that the spectral peaks below 4 kHz and the optimal order number for MUSIC, equivalent to the number of the spectral component, might be the key parameters which were highly correlated to the physiological states of the valve like the mechanical damage of the valve or the formation of thrombus on the valves.

  • PDF