• Title/Summary/Keyword: thrombosis

Search Result 953, Processing Time 0.02 seconds

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

The Effect of Platelets on Endothelin Production in Bovine Pulmonary Artery Endothelial Cells (혈소판이 소 폐동백 내피세포의 Endothelin 생산에 미치는 효과)

  • Lee, Sang-Do;Shim, Tae-Sun;Kwon, Seog-Woon;Ryu, Jin-Sook;Lee, Jae-Dam;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1114-1124
    • /
    • 1997
  • Background : Endothelin(ET) is a very potent vasoconstrictive peptide produced by endothelial cells of pulmonary artery. The endothelin level was increased in plasma of primary pulmonary hypertension and acute pulmonary thromboembolism and it was suggested that the endothelin might do a critical role in the cardiopulmonary dysfunction in these two conditions. But the exact mechanism of increase of ET has not been known. In these two conditions, platelet activation and thrombosis are the main pathophysiologic findings. So there is a possibility that the platelet might stimulate endothelin secretion from endothelial cells. Therefore, we performed this study to evaluate the role of platelet and its mediators on endothelin production in bovine pulmonary artery endothelial(BPAE) cells. Method : Bovine pulmonary artery endothelial cells, ATCC certified cell line 209, were cultured and treated with human platelets($10^6{\sim}10^8/ml$), thrombin (0.1~10u/ml), TGF-${\beta}1$(1~100uM), serotonin(1~100uM), and endotoxin(1ug/ml) in a final volume of 500ul for 18 hours. Levels of ir(immunoreactive)-ET in each conditioned medium were measured by a radioimmunoassay specific for ET. Result : The increase of ir-ET levels was platelet number and time dependent over 18 hours. When washed human platelets were added($10^8/ml$), the ir-ET levels were significantly higher than that of control(p<0.05) at 8 and 18 hours after culture. Subthreshold concentration of platelets($10^7/ml$) coincubated with endotoxin(1ug/ml) or subthreshold dose of thrombin(0.1u/ml) stimulated ir-ET secretion from BPAE cells significantly(p<0.05) compared with control. Thrombin(1ug/ml, 10ug/ml) and TGF-${\beta}1$(100pM, 1000pM) significantly increased ir-ET secretion from BP AE cells(p<0.05) compared with control, but serotoin(1~100uM) and endotoxin(1ug/ml) did not stimulate the ir-ET secretion. Conclusions : Platelets stimulate endothelin secretion from bovine pulmonary artery endothelial cells. The mechanism of increase of endothelin secretion seems to be a stimulation by platelet itself or by mediators, such as TGF-${\beta}1$, secreted from activated platelets. And, in this study, the priming effect of platelets on endothelin secretion from BPAE cells could be another possibility.

  • PDF

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.