• Title/Summary/Keyword: threshold values

Search Result 981, Processing Time 0.028 seconds

The Effect of Acupuncture with Magnetic Ring on Pain Threshold Using Algometer (자기장을 통한 침자극이 압통 역치에 미치는 영향)

  • Lee, Jong-Hoon;Min, Byung-Il;Hwang, Byung-Gil;Jang, Jin;Hong, Mu-Chang
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • Like acupuncture, magnetic therapy has been known to yield effectiveness when it is applied to relieve from fatigue, musculoskelectal diseases, sore sites, rheumatic arthritis and chronic pain syndromes. However, combined application of acupuncture and magnet has not yet been studied. This study is designed to investigate effectiveness of acupuncture therapy when in the magnetic field for the pain relief. Magnetic field was made by magnetic ring ($7{\psi}{\times}2.3{\psi}{\times}1.5mm$). Twenty-one male swimmers with latent muscular pain at the GB21 area in the university course of physical education in Daegu were chosen and divided into three groups; 1) acupuncture treatment group (n=7), 2) acupuncture treatment with iron ring group (n=7), 3) acupuncture treatment with magnetic ring group (n=7). Manual Acupuncture was given to the GB21 point for 20 minutes. The degree of pressure pain threshold (PPT, $kg/cm^2$) in GB21 was measured with algometer. Before acupuncture treatment, the PPT values were $6.08{\pm}1.69$, $6.39{\pm}1.72$ and $5.59{\pm}1.11$ in acupuncture treatment group, acupuncture treatment with iron ring group, acupuncture treatment with magnetic ring group, respectively. After acupuncture treatment, the PPT values were $6.48{\pm}2.33$, $6.31{\pm}1.31$ and $6.59{\pm}1.80$, respectively. Pressure threshold was significantly increased in the acupuncture treatment with magnetic ring group compared to the other groups. Based on these results, acupuncture treatment with magnetic ring produced better effects on pain threshold, and these effects can be considered to be associated with the currents or voltages induced by the acupuncture needle and magnetic ring at present.

  • PDF

The Preliminary Study for Normative Current Perception Threshold values in the Korean Adults (성인의 Current Perception Threshold 예비조사)

  • Park, Dae-Gyu;Chun, Sung-Hong;Jeon, Jae-Soo;Kim, Yong-Ik;Hwang, Kyung-Ho;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.5-10
    • /
    • 1997
  • Background : The Current Perception Threshold (CPT) provides an objective, quantitative gauge of sensory nerve integrity which is obtainable from any cutaneous site. CPT measurement can confirm and quantify or rule out dysfunction of nerve through comparison with established normative values ($Neuval^{TM}$ CPT database). The aim of this study is to compare collected data from Korean adults with $Neuval^{TM}$ CPT database. Method : Normative data from 5 standard test site in face, hand, toe were obtained from 50 healthy adults. Three frequencies(5, 250, 2000 Hz) were stimulated with $Neuromoter^{(R)}$ CPT device. Results : The results of our data were statistically significantly different than Neuval data except in face, but within normal range. Sensory Threshold increased as the frequency of the stimulus changed from 5 Hz to 250 Hz to 2000 Hz., and from face to hand to toe. Conclusion : CPT testing is a valuable neurologic testing modality that is noninvasive and highly reliable for diagnosis and evaluation of sensory nerves where neuropathy is suspected.

  • PDF

A Warning Threshold Proposal for Operation Improvement of Maritime DGPS Reference Station (해양용 DGPS 운영성 개선을 위한 시스템 경고 임계값 제안)

  • Choi, Yong Kwon;Lee, Ju Hyun;Son, Seok Bo;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.12-20
    • /
    • 2017
  • A maritime DGPS in Korea offers pseudo-range correction information and monitors integrity of correction data by using multiple GNSS receivers. The maritime DGPS reference station and integrity monitor service sets alarm threshold value about integrity monitoring parameters for preventing service interruption status. However there is no way to avoid system interruption according to malfunction of backup systems and outside factors. Therefore, in this paper, warning threshold values were proposed for maritime DGPS operator can be counteract in advance. And Markov analysis method was carried out for selection of these warning threshold values.

Estimation or Threshold Runoff on Han River Watershed (한강유역 한강유출량 산정)

  • Kim, Jin-Hoon;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.2 s.163
    • /
    • pp.151-160
    • /
    • 2006
  • In this study, threshold runoff which is a hydrologic component of flash flood guidance(FFG) is estimated by using Manning's bankfull flow and Geomorphoclimatic Instantaneous Unit Hydrograph(GcIUH) methods on Han River watershed. Geographic Information System(GIS) and 3' Digital Elevation Model database have been used to prepare the basin parameters of a very fine drainage area($1.02\~56.41km^2$), stream length and stream slope for threshold runoff computation. Also, cross-sectional data of basin and stream channel are collected for a statistical analysis of regional regression relationships and then those are used to estimate the stream parameters. The estimated threshold runoff values are ranged from 2 mm/h to 14 mm/6hr on Han River headwater basin with the 1-hour duration values are$97\%$ up to 8mm and the 6-hour values are $98\%$ up to 14mm. The sensitivity analysis shows that threshold runoff is more variative to the stream channel cross-sectional factors such as a stream slope, top width and friction slope than the drainage area. In comparisons between the computed threshold runoffs on this study area and the three other regions in the United States, the computed results on Han River watershed are reasonable.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Epidemiological application of the cycle threshold value of RT-PCR for estimating infection period in cases of SARS-CoV-2

  • Soonjong Bae;Jong-Myon Bae
    • Journal of Medicine and Life Science
    • /
    • v.20 no.3
    • /
    • pp.107-114
    • /
    • 2023
  • Epidemiological control of coronavirus disease 2019 (COVID-19) is needed to estimate the infection period of confirmed cases and identify potential cases. The present study, targeting confirmed cases for which the time of COVID-19 symptom onset was disclosed, aimed to investigate the relationship between intervals (day) from symptom onset to testing the cycle threshold (CT) values of real-time reverse transcription-polymerase chain reaction. Of the COVID-19 confirmed cases, those for which the date of suspected symptom onset in the epidemiological investigation was specifically disclosed were included in this study. Interval was defined as the number of days from symptom onset (as disclosed by the patient) to specimen collection for testing. A locally weighted regression smoothing (LOWESS) curve was applied, with intervals as explanatory variables and CT values (CTR for RdRp gene and CTE for E gene) as outcome variables. After finding its non-linear relationship, a polynomial regression model was applied to estimate the 95% confidence interval values of CTR and CTE by interval. The application of LOWESS in 331 patients identified a U-shaped curve relationship between the CTR and CTE values according to the number of interval days, and both CTR and CTE satisfied the quadratic model for interval days. Active application of these results to epidemiological investigations would minimize the chance of failing to identify individuals who are in contact with COVID-19 confirmed cases, thereby reducing the potential transmission of the virus to local communities.

Wavelet-Based Watermarking using Threshold Values and PN-Code for Copyright Protection (저작권 보호를 위한 임계값과 PN-Code를 이용한 웨이블릿 영역에서의 워터마킹)

  • 정용훈;오휘빈;최영규;이준환;이상범
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.561-568
    • /
    • 2003
  • This paper suggests that watermarking technique make use of Threshold Values and PN code for preservation of copyright. To protect copyright, six binary images that are generated by a Dynamic Threshold Value to LSB(least significant bit) of wavelet coefficient through wavelet conversion and watermark image use PN code to each frequency sphere-HL1, LH1, HL2, LH2, HL3, LH3, decide coordinates, operate XOR, and insert watermark. They put the sphere except from low frequency which has much image deterioration and high frequency which has weak loss compression in watermark. As an experimental result, we acquired watermark inserting image that has little image deterioration and extract watermark strongly.

  • PDF

Banding Artifacts Reduction Method in Multitoning Based on Threshold Modulation of MJBNM (MJBNM의 임계값 변조를 이용한 멀티토닝에서의 띠 결점 감소 방법)

  • Park Tae-Yong;Lee Myong-Young;Son Chang-Hwan;Ha Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.2 s.308
    • /
    • pp.40-47
    • /
    • 2006
  • This paper proposes a multitoning method using threshold modulation of MJBNM(Modified Jointly Blue Noise Mask) for banding artifacts reduction. As banding artifacts in multitoning appear as uniform dot distributions around the intermediate output levels, such multitone output results in discontinuity and visually unpleasing patterns in smooth transition regions. Therefore, to reduce these banding artifacts, the proposed method rearranges the dot distribution by introducing pixels in the neighborhood of output levels that occurs banding artifacts. First of all principal cause of banding artifacts are analyzed using mathematical description. Based on this analytical result, a threshold modulation technique of MJBNM which takes account of chrominance error and correlation between channels is applied. The original threshold range of MJBNM is first scaled linearly sot that the minimum and maximum of the scaled range include two pixel more than adjacent two output levels that cover an input value. In an input value is inside the vicinity of any intermediate output levels produce banding artifacts, the output is set to one of neighboring output levels based on the pointwise comparison result according to threshold modulation parameter that determines the dot density and distribution. In this case, adjacent pixels are introduced at the position where the scaled threshold values are located between two output levels and the minimum and maximum threshold values. Otherwise, a conventional multitoning method is applied. As a result, the proposed method effectively decreased the appearance of banding artifacts around the intermediate output levels. To evaluate the quality of the multitone result, HVS-WRMSE according to gray level for gray ramp image and S-CIELAB color difference for color ramp image are compared with other methods.

Tuning the Parameters for the Decision Making System in Order to Define Athlete's Aerobic and Anaerobic Thresholds

  • Ketola, Jaakko;Saastamoinen, Kalle;Turunen, Esko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.317-320
    • /
    • 2004
  • In this work we have managed to find parameters for defining athlete's aerobic and anaerobic thresholds. Thresholds which are of vital importance for top athletes. It is shown how differential evolution and different similarity measures has been used to tune computational model for threshold definitions. From our results it is obvious that the use of right parameter values for this kind expert system is of vital importance.

  • PDF

Quad Tree Representation and Compression for LiDAR Data (LiDAR 데이터의 Quad Tree 구조 표현과 압축에 관한 연구)

  • Lee, Hyo-Jong;Woo, Seung-Young;Jo, Ki-Seong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.753-754
    • /
    • 2008
  • LiDAR data are acknowledged as very useful method to represent 3-D geographical information. In this paper aquad tree has been utilized to represent the 3-D spatial information. Compression algorithm is implemented based on a given threshold. The efficiency of compress is very high with large threshold values.

  • PDF