• Title/Summary/Keyword: three-phase rectifiers

Search Result 55, Processing Time 0.022 seconds

Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply (보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감)

  • Kim, Jong-Su;Seo, Dong-Hoan;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • The input current of three phase rectifier which is mainly used in the propulsion system of the electric propulsion ship includes a variety of low order harmonics. To reduce these harmonics, the power conversion system, used in the large vessels which high power is required, is currently used the rectifiers of 12-pulse output, but it still has a problem that occurs $12{\pm}1$ harmonics. Also, in the case of the direct torque control technique which is widely used for the speed and torque control, the torque ripple is severe and the input current of motor has greatly included harmonics by the switching of the inverter. In order to reduce harmonics and improve the performance of torque control, this paper presents that the auxiliary supply assisted into the 12-pulse rectifier of the electric propulsion system using direct torque control technique. We confirm the validity of the proposed method through the simulation under the environment of a real vessel system.

A Study to Improve the DC Output Waveforms of AFE Three-Phase PWM Rectifiers (AFE 방식 3상 PWM 정류기의 직류 출력파형 개선에 관한 연구)

  • Jeon, Hyeon-Min;Yoon, Kyoung-Kuk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.739-745
    • /
    • 2017
  • Many studies have been conducted to reduce environmental pollution by ships and reduce fuel consumption. As part of this effort, research on power conversion systems through DC distribution systems that link renewable energy with conventional power grids has been pursued as well. The diode rectifiers currently used include many lower harmonics in the input current of the load and distort supply voltage to lower the power quality of the whole system. This distortion of voltage waveforms causes the malfunctions of generators, load devices and inverter pole switching elements, resulting in a large number of switching losses. In this paper, a controller is presented to improve DC output waveforms, the input Power Factor and the THD of an AFE type PWM rectifier used for PLL. DC output voltage waveforms have been improved, and the input Power Factor can now be matched to the unit power factor. In addition, the THD of the input power supply has been proven by simulation to comply with the requirements of IEEE Std514-2014.

Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method (직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법)

  • 김진선;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.213-221
    • /
    • 2004
  • In recent years, since more and more diode rectifiers with smoothing dc capacitor are used in electronic equipments, household appliances and ac drives, harmonics generated by these loads have become a major issue. In addition, 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. This systems show excessive currents in the neutral. These neutral currents are fundamentally third harmonic, and their presence is tied to wiring failure, elevating of neutral potentials, transformer overheating, etc. In response to the concerns, this paper proposes a series active power filter scheme based on direct compensating voltage extraction method and the advantage of this control algorithm is direct extraction of compensation voltage reference without multiplying gain. Therefore, the calculation of the compensation voltage reference will becom much simpler than other control algorithm. To verify the effectiveness of the proposed algorithm, a prototype active power filter is built and some experiments are carried out.

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie;Liu, Jinjun;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.175-182
    • /
    • 2014
  • Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.

A New High-Efficient Interleaved Converter for Low-Voltage and High-Current Power Systems (저전압 고전류 사양에 적합한 고효율 인터리브 컨버터)

  • Cho, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.600-608
    • /
    • 2016
  • This paper proposes a new high-efficient interleaved phase-shift full-bridge (PSFB) converter for low-voltage and high-current power systems. The proposed converter is composed of three switch-bridges and two transformers in the primary side and two rectifiers in the secondary side. Each transformer handles half of the total power with an interleaved operation, so that the proposed converter has high system reliability, as much as the conventional interleaved PSFB converter. The soft-switching characteristics of the proposed converter are better than those of the conventional converter due to the modulated primary side configuration. The proposed converter represents a single lagging-leg bridge, which has a poor soft switching condition in its operation, while the conventional converter has two lagging-leg bridges in its operation. Therefore, the number of switches having hard-switching conditions is reduced by half in the proposed converter. In addition, the reduced switch counts in the primary side of the proposed converter helps decrease the complexity of the proposed converter compared to that of the conventional converter. The operational principle and analysis are presented in this paper and the characteristics are verified using a PSIM simulation with 3kW server power specification.