• Title/Summary/Keyword: three legs

Search Result 248, Processing Time 0.03 seconds

Comparison of House Folkore in China, Korea and Japan (중·한·일 세 나라의 주거민속 연구 -조왕(竈王)-)

  • Kim, kwang-on
    • Korean Journal of Heritage: History & Science
    • /
    • v.34
    • /
    • pp.172-195
    • /
    • 2001
  • This research on the house folklore in China, Korea, and Japan is focusing on a kitchen God that is common in these three countries. This god originated in China and has subsequently influenced Korea and Japan. Today, all three countries use the same name of this kitchen god which is called Youngwang(竈王) as its name has been spelled in Chinese. In China, this kitchen god has been believed in two different ways. The Han people have developed their belief in Youngwang while another creed has been originated from other ethnic groups. Because of the particular house style with upper stories of ethnic groups in the southern and southeast areas of China, a kitchen fireplace is centered in the house. Han people in China also worship painted depictions of kitchen gods. And the ethnic groups believe it has three stone legs for a fire box. These differing beliefs has bad influenced on Korea and Japan. The kitchen god of Cheju island (off the south Korea coast) is believed to be almost the same as among the ethnic groups in China Interestingly, form of belief in the kitchen god in Okinawa (off the south coast of Japan) is almost identical as in the southern area of China Custom in China. Korea, and Japan regarding the kitchen god symbolized family values healing, initiating a new daughter-in-law to reveging the kitchen god, etc. are all the very similar. A fireplace and its fire are very important and, have many taboo, attached. Existing rich tales of kitchen gods are similar in the three countries. Moreover, people in the three countries, think that the clay or time plaster of the fireplace with bring good luck on New Year's eve. However, Korea kitchen god features one thing that is different from those China and Japan, that is that water symbolizes the kitchen god in Korea. A painted kitchen god as they are popular in China, has influenced only some Buddhist temples in Korea.

Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model

  • Dae Joong Kim;Kun Hwang;Hun Kim;Jang Gyu Cha;Hyungseok Jang;Ju-Yong Park;Yeo Ju Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.782-791
    • /
    • 2021
  • Objective: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. Materials and Methods: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. Results: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. Conclusion: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone.

Assessment of the Structural Collapse Behavior of Between Offshore Supply Vessel and Leg in the Jack-up Drilling Rig (잭업드릴링 리그의 레그와 작업 지원선 충돌에 의한 구조붕괴 거동 평가)

  • Park, Joo-Shin;Seo, Jung-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.601-609
    • /
    • 2022
  • Jack-up drilling rigs are mobile offshore platforms widely used in the offshore oil and gas exploration industry. These are independent, three-legged, self-elevating units with a cantilevered drilling facility for drilling and production. A typical jack-up rig includes a triangular hull, a tower derrick, a cantilever, a jackcase, living quarters and legs which comprise three-chord, open-truss, X-braced structure with a spudcan. Generally, jack-up rigs can only operate in water depths ranging from 130m to 170m. Recently, there has been an increasing demand for jack-up rigs for operating at deeper water levels and harsher environmental conditions such as waves, currents and wind loads. All static and dynamic loads are supported through legs in the jack-up mode. The most important issue by society is to secure the safety of the leg structure against collision that causes large instantaneous impact energy. In this study, nonlinear FE -analysis and verification of the requirement against collision for 35MJ recommended by DNV was performed using LS-Dyna software. The colliding ship used a 7,500ton of shore supply vessel, and five scenarios of collisions were selected. From the results, all conditions do not satisfy the class requirement of 35MJ. The loading conditions associated with chord collision are reasonable collision energy of 15M and brace collisions are 6MJ. Therefore, it can be confirmed that the identical collision criteria by DNV need to be modified based on collision scenarios and colliding members.

3D Modeling of Safety Leg Guards Considering Skin Deformation and shape (피부길이변화를 고려한 3차원 다리보호대 모델링)

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.24 no.4
    • /
    • pp.555-569
    • /
    • 2015
  • During a design process of a protective equipment for sports activities, minimizing movement restrictions is important for enhancing its functions particularly for protection. This study presents a three-dimensional(3D) modeling methodology for designing baseball catcher's leg guards that will allow maximum possible performance, while providing necessary protection. 3D scanning is performed on three positions frequently used by a catcher during the course of a game by putting markings on the subject's legs at 3cm intervals : a standing, a half squat with knees bent to 90 degrees and 120 degrees of knee flexion. Using data obtained from the 3D scan, we analyzed the changes in skin length, radii of curvatures, and cross-sectional shapes, depending on the degree of knee flexion. The results of the analysis were used to decide an on the ideal segmentation of the leg guards by modeling posture. Knee flexions to 90 degrees and to $120^{\circ}$ induced lengthwise extensions than a standing. In particular, the vertical length from the center of the leg increases to a substantially higher degree when compared to those increased from the inner and the outer side of the leg. The degree of extension is varied by positions. Therefore, the leg guards are segmented at points where the rate of increase changed. It resulted in a three-part segmentation of the leg guards at the thigh, the knee, and the shin. Since the 120 degree knee-flexion posture can accommodate other positions as well, the related 3D data are used for modeling Leg Guard (A) with the loft method. At the same time, Leg Guard (B) was modeled with two-part segmentation without separating the knee and the shin as in existing products. A biomechanical analysis of the new design is performed by simulating a 3D dynamic analysis. The analysis revealed that the three-part type (A) leg guards required less energy from the human body than the two-part type (B).

Comparative efficacy of three topical anesthetics on 7-11-year-old children: a randomized clinical study

  • Dasarraju, Rupak Kumar;SVSG, Nirmala
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.1
    • /
    • pp.29-37
    • /
    • 2020
  • Background: This study evaluated the efficacy of three intraoral topical anesthetics in reducing the injection needle prick pain from local anesthetic among children aged 7-11 years old. Methods: It is a prospective, Interventional, parallel design, single-blind, randomized clinical trial in which subjects (n=90) aged 7-11 years were included in the study based on an inclusion criteria. Subjects were divided into three groups based on computer-generated randomization with an allocation ratio of 1:1:1. Groups A, B, and C received benzocaine 20% jelly (Mucopain gel, ICPA health products Ltd, Ankleshwar, India), cetacaine anesthetic liquid (Cetylite Industries, Inc, Pennsauken, NJ), and EMLA cream (2% AstraZeneca UK Ltd, Luton, UK), respectively, according to manufacturer's instructions, for 1 minute prior to local anesthetic injection. After application of topical anesthetic agent, for all the groups, baseline pre-operative (prior to topical anesthetic administration) and post-operative scores (after local anesthetic administration) of pulse rate was recorded using Pulse oximeter (Gibson, Fingertip Pulse Oximeter, MD300C29, Beijing Choice Electronic). Peri-operative (i.e., during the administration of local anesthesia) scores were recorded using Face, Legs, Activity, Cry, Consolability (FLACC) Scale, Modified Children hospital of Eastern Ontario Pain Scale (CPS) behavior rating scale, and Faces Pain Scale (FPS-R) - Revised (For self-reported pain). Direct self-reported and physiological measures were ascertained using FPS-R - Revised and Pulse oximeter, respectively, whereas CPS and FLACC scales assessed behavioral measures. To test the mean difference between the three groups, a one way ANOVA with post hoc tests was used. For statistical significance, a two-tailed probability value of P < 0.05 was considered as significant. Results: The Cetacaine group had significantly lower pain scores for self-report (P < 0.001), behavioral, and physiological measures (P < 0.001) than the other two groups. However, there was no significant difference between the Benzocaine group and EMLA group during palatal injection prick. Conclusion: Cetacaine can be considered as an effective topical anesthetic agent compared to benzocaine 20% jelly (Mucopain gel) and EMLA cream.

Effect of Basal Physical Fitness and ADL Function in the Aged According to Horse Riding Exercise (실내 승마운동이 고령자의 기초체력 및 ADL 기능에 미치는 효과)

  • Kim, E.R.;Kang, S.R.;Yu, C.H.;Moon, D.A.;Park, S.Y.;Kwon, T.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.163-169
    • /
    • 2013
  • The purpose of this study was to verify exercise effect of horse riding exercise according to estimate basal physical fitness and activities of daily living(ADL) function in the aged. Participants were nineteen peoples who have no impediment of activity. They performed horse riding exercise using SRider(Neipplus, Co., Korea) at sixty minutes a day. Exercise has progressed three days a week for eight weeks. We measured trunk flexion, sit up, whole body reaction, leg strength and maximal oxygen uptake as basal physical fitness. Also three meter gait, single stance with eyes opened and single stance with eyes closed as ADL function were estimated once a month. The result of legs strength and whole body reaction showed the higher significantly than before the exercise. Moreover, the result of three meter walking ability only increased significantly among the ADL function. This means that horse riding exercise might be activated continuous muscular contraction with maintained tonus of muscle. We thought that continuous movement of horse riding could be lead to isometric muscle contraction in lower limbs. Our study found that horse riding exercise could improve lower strengths and muscle reaction for exercise effect. Also we suggested that horse riding exercise could be adapted to exercise methods that could provide rehabilitation and treatment enough for the aged or disabled person.

Study on Improvement of Working Environment in Plastic House to Prevent Plastic House Syndrome (하우스증 예방을 위한 비닐하우스내 작업환경 개선에 관한 연구)

  • 김명주;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.5 no.2
    • /
    • pp.107-115
    • /
    • 1994
  • This study was conducted to provide a counterplan for preventing so celled “plastic house syndrome” revealed among farmers spending much time in the plastic houses. For this, working environment inside a plastic house was observed. Then, experiments were carried out mostly in a climatic chamber with three kinds of working posture on uneven($D_1-F_1$) or even($D_2-F_2$) ground surface. Tested work loads with three kinds of working posture were : moving in a sitting posture with attaching breast to legs and waving arms ($A_1$), moving in a bending posture with waving arms ($B_1$), and moving a 6kg weighting luggage in a standing posture ($C_1$) Physiological responses in the workers to three different work loads were observed in a climatic chamber, with or without using some instruments, to evaluate work efficiencies. The results obtained are summerized as follows. 1. $C_1$ was the hardest work and $B_1$ was harder than $A_1$ on the even ground. 2. Worker's physiological fatigue and physical loads remarkably decreased when using the instruments such as a chair and a cart with some rollers on the even ground. 3. Working with pushing a cart($F_1$) was the hardest work, and standing($D_1$) was harder than walking($E_1$) on the uneven ground. 4. Worker's physiological fatigues and physical loads remarkably decreased on the even ground. 5. Similar results were obtained when the same experiment was carried out in a plastic house.

  • PDF

Notes on Three Species of the Laboulbeniales (Ascomycotina) Newly Collected from Korea (한국산 충생자낭균류의 미기록종에 관하여)

  • Lee, Yong-Bo;Na, Young-Hee
    • The Korean Journal of Mycology
    • /
    • v.27 no.3 s.90
    • /
    • pp.208-210
    • /
    • 1999
  • Three species belong to the genus Laboulbenia were collected on Carabidae (Coleoptera) and Harpalidae (Coleoptera) from several regions of Korea. Laboulbenia anoplogenii Thaxter was collected from Stenolophus quinquepustulatus Widemann. The characters of this species are the fourth layer of receptacle consisted of two or three cells and the distal end of its posterior cell projecting upward. The thalli were produced on posterior and anterior legs of the hosts. Laboulbenia habui Terada was collected from Chlaenius variicornis Bates. This species is characterized by the basal cells of the secondary appendage composed of short-cylindrical cells, arranged alternately on a double row. The thalli were produced from the elytra and anterior abdomen of the hosts. Laboulbenia pallida Thaxter was collected from Anisodactylus signatus Panzer. This species is distinguished from other related species by the rounded tip of perithecium and the outer appendage branched on the basal cell. The thalli were produced on the posterior elytra of the hosts.

  • PDF

A new species of Parastenocaris from Korea, with a redescription of the closely related P. biwae from Japan (Copepoda: Harpacticoida: Parastenocarididae)

  • Karanovic, Tomislav;Lee, Wonchoel
    • Journal of Species Research
    • /
    • v.1 no.1
    • /
    • pp.4-34
    • /
    • 2012
  • Parastenocaris koreana sp. nov. is described based on examination of numerous adult specimens of both sexes from several localities in Korea. Scanning electron micrographs are used to examine intra- and interpopulation variability of micro-characters, in addition to light microscopy. The new species is most closely related to the Japanese P. biwae Miura, 1969, which we redescribe based on newly collected material from the Lake Biwa drainage area. The two species differ in size, relative length of the caudal rami, shape of the anal operculum, shape of the genital double somite, relative length of the inner distal process on the female fifth leg, as well as relative length of the apical setae on the second, third, and fourth legs exopods in both sexes. Detailed examinations of three disjunct populations of P. koreana reveal also some geographical variation, especially in the surface ornamentation of somites, which may indicate some population structuring or even cryptic speciation. Lack of intraspecific variability in the number and position of sensilla on somites, as well as their potential phylogenetic significance, is a novel discovery. Both species examined here belong to the brevipes group, which we redefine to include 20 species from India (including Sri Lanka), Australia, East Asia, Northern Europe, and North America. A key to species of this group is also provided. In order to test the monophyly of the redefined brevipes group with highly disjunct distribution, as well as relationship between different species, a cladistics analysis is performed based on 39 morphological characters and with help of three outgroup taxa. Six equally parsimonious cladograms are generated, all of which show that the ingroup is well defined by at least three synapomorphies. Reconstructed phylogeny questions the previously suggested hypothesis about the origin of this group in South East Asia, with one Australian species showing the most basal position. We speculate that the present distribution of this group may be a combination of ancient vicariance and subsequent dispersal, with a possible origin in the Gondwanaland, in the rift valley between Australia and India.

Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems

  • Cho, Young-Shin;Jang, Seong-Ho;Cho, Jae-Sung;Kim, Mi-Jung;Lee, Hyeok Dong;Lee, Sung Young;Moon, Sang-Bok
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.872-883
    • /
    • 2018
  • Objective To replace camera-based three-dimensional motion analyzers which are widely used to analyze body movements and gait but are also costly and require a large dedicated space, this study evaluates the validity and reliability of inertial measurement unit (IMU)-based systems by analyzing their spatio-temporal and kinematic measurement parameters. Methods The investigation was conducted in three separate hospitals with three healthy participants. IMUs were attached to the abdomen as well as the thigh, shank, and foot of both legs of each participant. Each participant then completed a 10-m gait course 10 times. During each gait cycle, the hips, knees, and ankle joints were observed from the sagittal, frontal, and transverse planes. The experiments were conducted with both a camera-based system and an IMU-based system. The measured gait analysis data were evaluated for validity and reliability using root mean square error (RMSE) and intraclass correlation coefficient (ICC) analyses. Results The differences between the RMSE values of the two systems determined through kinematic parameters ranged from a minimum of 1.83 to a maximum of 3.98 with a tolerance close to 1%. The results of this study also confirmed the reliability of the IMU-based system, and all of the variables showed a statistically high ICC. Conclusion These results confirmed that IMU-based systems can reliably replace camera-based systems for clinical body motion and gait analyses.