• 제목/요약/키워드: three dimensional motion

검색결과 1,016건 처리시간 0.023초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

재활운동 프로그램에 참가한 엉덩인공관절 수술자의 하지근력 변화에 대한 비교연구 (Lower Limbs Muscle Comparative Research for Verification Effect of Rehabilitation Training Program of Total Hip Arthroplasty)

  • 진영완
    • 생명과학회지
    • /
    • 제20권4호
    • /
    • pp.543-548
    • /
    • 2010
  • 엉덩인공관절 수술 후 지속적으로 재활운동에 참가한 사람들을 대상으로 6개월 지난 시점과 12개월 지난 시점에서 하지근력 테스트와 지면반력 실험을 통하여 재활훈련의 효과를 비교하고 검증하였다. 엉덩관절이 $150^{\circ}$에서 $90^{\circ}$까지 굴곡하는 동안 대퇴직근의 변화를 비교해 본 결과 통계적으로는 유의한 차이(p<0.05)가 나타나지 않았으나 평균의 비교에서 약간의 차이가 있었다. 장요근 평균의 비교에서도 통계적으로 유의한 차이(p<0.05)는 나타나지 않았으나 평균의 비교에서 모든 구간에서 재활훈련기간이 길어질수록 더욱더 큰 값을 나타내고 있는 것으로 보아 굴곡과 신전에 관계하는 근력들이 체계적인 재활훈련을 받을 경우 더욱더 좋아지는 것으로 나타났다. 엉덩관절이 $0^{\circ}$에서 $45^{\circ}$까지 외전하는 동안 중둔근의 변화는 통계적으로 유의한 차이(p<0.05)는 없었으나 재활훈련에 꾸준히 12개월 동안 참가한 수술자가 6개월 재활훈련에 참가한 수술자들보다 외전동작 값이 훨씬 크게 나타났다. 소둔근의 근력변화는 중둔근 보다 외전각도가 $45^{\circ}$각도로 커지면서 12개월 재활훈련에 참가한 수술자의 근력값($0.37{\pm}0.08$)이 6개월 재활훈련 참가자 근력값($0.21{\pm}0.05$) 보다 훨씬 커지는 것으로 나타났다. 무릎관절의 모멘트 값은 통계적으로 유의한 차이(p<0.05)는 없었으나 평균의 비교에서 한 계단을 오르는 동안 시간의 경과에 따라 재활훈련이 길수록 무릎을 펴는 모멘트의 값이 더욱더 크게 증가하는 것으로 나타났다. 엉덩인공관절 수술 후 6개월 재활훈련 참가자와 12개월 재활훈련 참가자 모두 세 가지 지면반력(Fx anterior/posterior force, Fy medio/lateral force, Fz vertical force)의 형태는 통계적으로 유의한 차이는 나타나지 않았으나, 좌우면의 힘(Fy)은 6개월 재활훈련 참가자($109{\pm}45N$)가 12월 재활훈련 참가자($105{\pm}28N$)보다 큰 값을 보이고 있고, 전후면의 힘(Fx) 값은 6개월 재활훈련참가자($-107{\pm}21N$) 보다 12개월 재활훈련 참가자($-175{\pm}33N$)가 큰 값으로 나타났다.

디즈니 애니메이션에 나타난 모더니즘 회화스타일 : 색, 형태, 공간을 중심으로 (Modernist painting style in Disney animation)

  • 문재철;김유미
    • 만화애니메이션 연구
    • /
    • 통권33호
    • /
    • pp.31-53
    • /
    • 2013
  • 20세기 초 모더니즘 예술의 다양한 실험은 필름과 카메라의 발명과 함께 애니메이션을 탄생시켰다. 초창기에는 영화, 사진, 미술 등 예술가들에 의해 이미지와 시간을 접목한 다양한 분야의 이미지 실험이 이루어졌다. 그러나 이후 애니메이션이 상업적으로 성공을 거두면서 점차 흥미위주의 작품이 주류로 자리 잡아 갔으며, 초기 애니메이션의 실험적 특성은 소위 비주류 애니메이션으로 명맥이 유지되었다. 디즈니 애니메이션 역시 상업적인 작품을 제작하면서 초기작품의 실험적 형태, 움직임의 표현, 그리고 초현실주의적 관점이 반영돼 모더니즘 예술로 긍정적인 평가를 받아왔었지만, 점차 영화적 리얼리즘을 표방하여 3차원적 영상 이미지 표현에 몰두하였다. 그 예로 애니메이터들에겐 드로잉과 라이브액션 푸티지(liveaction footage)를 연구하는 클래스를 열어 사람과 동물의 움직임을 재현하는 테크닉을 발전시켜갔다. 또한 2차원 원급법의 표현적 한계를 극복하고자 기술적으로 멀티플레인 카메라(multiplane camera), 3D컴퓨터그래픽스와의 합성 등 이미지의 입체감을 강화시켜갔다. 더욱이 내용면으로 대중적인 동화 소재의 선택과 월트 디즈니 개인의 실사영화에 대한 관심은 애니메이션 연출에서 헐리우드 영화적 내러티브의 관습과 이미지 재현의 사실성을 강화시켜 초기 작품들이 갖고 있던 고유의 특성이 변질되면서 디즈니 애니메이션은 하위 영상문화 또는 아동적인 것으로 인식되는 원인이 됐다. 그러나 사라진 듯 보인 초기 모더니즘의 특성들은 이미지 표현에 있어 현재에도 디즈니 애니메이션에 계승되고 있다. 여전히 장르의 특성상 내러티브의 범주에서 디자인의 대상성은 중요시되지만 그 표현에 있어서는, 모더니즘 회화가 추구했던 이미지의 단순화와 과장으로 형태와 색이 줄 수 있는 심리적작용은 애니메이션 디자인에 활용되어 과거에 비해 그 특성은 더욱 강화됐다. 먼저 간단한 도형의 형태로 단순화된 모더니즘 회화의 특성은 캐릭터 디자인에 차용되고, 색은 대상의 장식이나 고증적 재현의 일차원적 목표를 넘어 카메라와 인물의 움직임으로 한 하면에서 배치가 바뀌면서 충돌 상쇄하여 관객에게 내적 경험을 유도하게 한다. 추상회화에서 색의 해방이 평면성으로 귀결된 것과 같이 캐릭터의 단순화된 개념적 색상의 사용은 캐릭터를 평면적으로 보이게 할뿐더러 이와 대조되는 공간은 더욱 평면적으로 나타나게 된다. 또한 카메라 움직임에 따라 드러나는 배경의 다중시점은 다양한 각도에서 대상의 본질을 표현하려한 모더니즘 회화를 연상시키기에 충분하다. 이러한 특성들이 초기 모더니즘 회화가 줬던 경험을 환기시킨다는 점에 입각하여 본 연구는 현대 작품들 사례를 중심으로 단순화 또는 과장된 형태, 내적표현의 색, 그리고 공간 사건의 배경의 역할을 유지하면서 움직임이 주는 경험을 20세기 초 모더니즘 회화의 특성과 비교 분석한다.

전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향 (Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer)

  • 곽정원;신정욱;김진성;박성용;신동호;윤명근;박소아;김동욱;임영경;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.291-297
    • /
    • 2010
  • 본 연구에서는 양성자 치료에서 치료부위에 금 마커를 삽입하였을 때 양성자 빔의 선량과 그 분포에 미치는 영향을 평가하였다. 1.2 mm 직경에 3 mm 길이의 원통형 금 마커가 사용되었고 양성자 빔의 여러 위치에서 각각의 선량에 미치는 영향을 조사하였다. 3차원 moving 팬텀과 유효 반경이 0.5 mm인 정위적 방사선 치료용 다이로드 검출기를 이용하여 금마커의 방사선 선량으로의 영향을 결정하였다. Gafchromic film을 이용한 필름에 의한 선량 평가도 시행하였다. 그리고 선량-체적관계 히스토그램을 통한 분석을 위하여 GEANT4 전산 모의 도구 모음을 이용한 전산모의를 실시하였다. 마커의 움직임에 대한 영향성을 평가하기 위하여 직장 풍선을 적용하고 금 마커를 삽입한 10명의 환자에 대한 MV 영상을 이용하였다. 하나의 금 마커에 의하여 처방선량의 95% 이하가 들어간 체적은 0.15 cc로 작지만 그 체적은 치료부위 안쪽에 위치하고 평행이동에 대하여 발려져서 없어지지 않았다. 금 마커의 위치와 양성자 빔의 상태에 따라서 선량분포에 각각 다른 영향을 미치고 이는 임상치료에서 충분히 고려되어야 할 것으로 사료된다.

시각적 연출에 의한 3D 입체 애니메이션 표현 연구: 〈드래곤 길들이기〉를 중심으로 (A Study on Expressing 3D Animation by Visual Direction : focused on 〈 How to train your dragon 〉)

  • 김정현
    • 만화애니메이션 연구
    • /
    • 통권26호
    • /
    • pp.1-30
    • /
    • 2012
  • 애니메이션의 목적은 움직임을 통해 재미있는 스토리를 관객에게 전달하는 것이라고 할 수 있다. 이러한 목적을 달성하기 위해 애니메이션은 탄생 이후 지금까지 100여년 이상의 시간동안 수많은 기술들을 도입하면서 다양한 내러티브 방법과 시각 표현 방법을 개발해 왔다. 또한 표현 기술력이 발달하면서 애니메이션을 구성하는 모든 요소들도 점점 체계화되어 왔고, 동시에 현실 그 이상의 세계를 표현할 수 있도록 해 주었다. 말 그대로 애니메이션을 제작하는 감독이 상상하는 모든 것들을 스크린을 통해 관객이 눈으로 볼 수 있는 시대가 된 것이다. 그리고 현재에는 애니메이션을 관람하는 관객이 마냥 프레임 안에서 움직이는 그림에 의해 즐거움을 느끼게 되는 시대를 넘어서도록 많은 노력이 이루어지고 있다. 즉, 수동적으로 바라보는 애니메이션을 넘어 관객이 직접 느끼며, 체감하는 애니메이션으로 목적성이 변화하고 있다는 것이다. 이런 과정에서 그 중심에 3D 입체라는 기술이 애니메이션의 새로운 즐거움을 표현할 수 있도록 해주고 있다. 얼마 전, 국내에서도 극장용 3D 입체 애니메이션이 제작되었으나, 해외의 3D 입체 애니메이션과 같은 완성도 높은 영상미를 기대했던 관객에게 새로운 즐거움을 주지 못해 흥행 면에서 이렇다 할 성적을 거두지 못하였다. 이것은 국내의 입체 애니메이션 제작 산업이 아직 초보적인 단계에 불과하여 3D 입체 애니메이션 제작에 대한 인력 및 기술, 경험이 절대적으로 부족한 상태에서 제작되었기 때문이다. 그리고 대부분의 입체에 대한 연구가 재현 기술적 문제에 집중되어 있어 관객들이 직접적으로 접하게 되는 영상 그 자체에 대한 연구 또한 부족하거나 미흡한 실정인 것도 커다란 문제라 할 수 있다. 이러한 국내 상황 속에서 2010년에 개봉되었고, 현재까지 최고의 3D 입체 애니메이션 흥행작으로 손꼽히고 있는 드림웍스 작품인 <드래곤 길들이기>의 입체영상 화면은 연구될 가치가 충분하다 할 수 있다. 따라서 본 논문은 양질의 국내 3D 입체 애니메이션 제작 및 전문 인력 양성 시기초자료로 활용되고자 풍부한 입체감을 전달하기 위해 화면을 담아내는 시각적 연출을 중심으로 이론적 고찰과 사례를 분석하여 연구하였다. 그 결과 3D 입체 애니메이션은 새로운 분야가 아닌 기존 영상미학의 원리를 기반으로 입체영상의 특성이 적용되어져 확장되고 변화된 영역인 것을 알 수 있었다. 이러한 연구를 통해 실재감 재현을 위한 3D 입체 애니메이션 콘텐츠 제작에 필요한 이론적 기초연구의 토대를 구축하는데 도움이 될 것으로 본다.

잠긴수제가 설치된 만곡수로에서의 이차류 거동 수치모의 (Numerical modeling of secondary flow behavior in a meandering channel with submerged vanes)

  • 이정섭;박상덕;최철희;백중철
    • 한국수자원학회논문집
    • /
    • 제52권10호
    • /
    • pp.743-752
    • /
    • 2019
  • 만곡수로에서의 흐름은 나선형 운동 형태의 이차류가 지배적이며, 이로 인해 일반적으로 만곡 외측을 따라 침식 현상이 발생하게 된다. 이러한 이차류를 약화시키기 위해서 보통 만곡수로 외측을 따라서 수제와 같은 수공구조물을 설치한다. 이 연구에서는 OpenFOAM 오프소스 소프트웨어를 토대로 난류 해석을 위한 하이브리드 RANS/LES 기법과 자유수면 해석을 위한 VoF기법을 이용한 3차원 수치모의를 통해서 $90^{\circ}$ 만곡수로에 설치된 잠긴수제가 후루드수가 0.43인 조건에서 이차류의 발달에 미치는 영향을 분석하였다. 시간과 공간에 대해서 2차 정확도의 유한체적법을 이용하여 수치모의를 수행하였으며, 수치해석 결과는 실험결과와 비교하여 수치모의의 정확도를 평가하였다. 잠긴수제가 설치된 경우의 수치모의 결과를 흐름방향 유속 분포와 횡방향 순환 유속벡터장을 중심으로 수리실험 관측값들과 비교할 때 수치모의 결과는 수리실험에서 관측된 주요 이차류 흐름 거동과 현상들을 대부분 양호한 정확도로 잘 재현하는 것으로 나타났다. 수치모의 결과를 비교해보면, 잠긴수제 설치로 인해서 만곡이 끝나는 단면 외측 하상부근에서의 유속은 약 평균유속의 1/3 정도 감소하는 반면에 수제 상단부에서의 전단층 발달에 따른 흐름 가속으로 자유수면 부근까지 유속이 증가하고 만곡 수충부에서는 수면 부근 유속이 약 20% 증가하는 것으로 나타났다. 결과적으로 잠긴수제는 만곡부에서 발생하는 이차류의 강도를 약화시켜 만곡부 외측 하상의 안정에 도움이 될 것으로 판단된다. 한편, 각 잠긴수제 전면부에서 말발굽와가 그리고 후면부에서는 후류가 형성되면서 수제 구조물 주변에서 강한 국부세굴이 발생하는 것으로 나타남으로, 국부세굴을 최소화할 수 있는 수제의 형상 및 배열에 대한 추가 연구가 요구된다.