• Title/Summary/Keyword: thickness of lens

Search Result 187, Processing Time 0.022 seconds

Analytical Study of the Image Reconstruction of Fourier Holograms Using Varifocal Electric-Field-Driven Liquid Crystal Fresnel Lenses

  • Kim, Taehyeon;Lee, Seung-Chul;Park, Woo-Sang
    • Current Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2020
  • A novel method is proposed for controlling the distance of an image plane in Fourier holograms using varifocal electric-field-driven liquid-crystal (ELC) lenses. Phase Fresnel lenses are employed to reduce the thickness and response time of the ELC lenses. The voltages applied to the electrodes of the ELC Fresnel lens are adjusted so that the lens has the same retardation distribution as an ideal lens. The focal length can be controlled by changing the retardation distribution with the applied voltages. Simulations were conducted for the image reconstruction of Fourier holograms with various focal lengths of the ELC Fresnel lenses. The simulation results indicate that the distance of the image plane can be properly controlled with the varifocal ELC Fresnel lens.

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

Micro lens system design for the optical fiber communication (광통신 변조기용 미세광학소자의 설계)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.217-221
    • /
    • 1992
  • A micro lens system was designed for the modulator in optical fiber communication. One was the collimating lens which transferred the diffracted beam from optical fiber to the modulator. The other was the coupling lens which connected the modulated collimating beam to the optical fiber. The light source was He-Ne laser beam. The lens would be made of optical glass BK-7. We determined the tolerance of curvature radius, thickness and conic constant.

  • PDF

Fundamentals of Contact Lens Movement (콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2008
  • Purpose: This review article was written to investigate what kind of forces are acting on the contact lens fitted on the cornea and its subsequent motion. Methods: A capillary action-induced force develops in the tear layer between the lens and cornea, which leads to the restoring force due to difference in layer thickness according to lens rotation. The characteristics of the lens movement can be determined by the various factors such as friction between eyelid and lens, acceleration force based on blinking and the restoring force incorporated with the viscous damping force. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped motion of lenses. The model predicts the time dependence of lenses during and after the blink varying the BC, blink period and eyelid pressure. Results: It was found that both the blink period and lid pressure increases the movement increases because of the enhanced lid friction. As the BC increases the viscous damping reduces due to the lacrimal layer's increase which resulted in the enhanced lens motion. After blink the lens illustrates the damped oscillation because of the restoring force by the increased lacrimal layer thickness and reduced viscous resistance. The time for the lens to return to the equilibrium shortens as the BC increase because of the resistance reduction. Conclusions: The movement of the contact lens is governed by the characteristics of the lacrimal layer between the lens and cornea as well as the lid blink.

  • PDF

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

Design of a Rod-Type Aspheric Lens Collimator for Optical Telecommunication (막대 형태의 비구면 렌즈를 이용한 광통신용 시준기의 설계)

  • Kang, Seok-Bong;Kang, Eun-Kyoung;HwangBo, Chang-Kwon;Kang, Sang-Do;Kim, Jong-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • A rod-type aspheric lens collimator for the optical telecommunication system which shows high coupling efficiency and experiences small coupling loss for misalignment errors is designed. The working distance, thickness, and diameter of the rod-type aspheric lens are determined to be close to those of the GRIN lens collimator in order to replace the GRIN lens with the rod-type aspheric lens. Since the coupling loss mainly originated from the spherical aberration of the lens, the spherical aberration in the rod-type aspheric lens is reduced drastically, and it turns out that the coupling efficiency of the rod-type aspheric lens collimator is higher than that of the available collimators, such as ball lens, GRIN lens, and C-type lens collimators.

Dose Assessment of Orbital Adnexa in Electron Beam Therapy for Orbital Lymphoma (안와림프종의 전자선 치료 시 안구 부속기관에 대한 선량평가)

  • Dong Hwan Kim;Yong In Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.283-292
    • /
    • 2024
  • Radiation side effects and complications on the ocular adnexa during electron beam therapy for orbital lymphoma can increase the incidence of posterior subcapsular cataracts. This study simulated a medical linear accelerator and a mathematical model of the eye using monte carlo simulations to evaluate the dose to the ocular adnexa and compare the shielding effectiveness on different parts of the ocular adnexa based on lens shield thickness. The dose assessment results of the ocular adnexa showed that the lens's sensitive area had the highest absorbed dose distribution when no shield was used, followed by the lens's non-sensitive area, the anterior chamber, vitreous humor, cornea, and eyelid in descending order. With the use of a shield, a 2 mm thick shield demonstrated a dose reduction effect of over 90% in the lens's sensitive area, over 83% in the non-sensitive area and anterior chamber, and a dose reduction effect of 30 to 62% in the vitreous body, cornea, and eyelid. For dose reduction in the lens's sensitive area during electron beam therapy for orbital lymphoma, it is necessary to use a shield of at least 2 mm thickness. Additionally, shielding strategies considering the thickness and area of the shield for other ocular adnexa besides the lens are required.

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

Athermal Elastomeric Lens Mount for Space Optics

  • Kihm, Hag-Yong;Yang, Ho-Soon;Moon, Il-Kweon;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.201-205
    • /
    • 2009
  • We investigated the optimum adhesive thickness for athermalizing an elastomeric lens mount in our space optics application. Theoretical results were compared with finite element solutions using two different models; discrete circular pads and discrete circular pads with columns filling the insertion holes reflecting the reality. A noticeable difference between their optimal thicknesses was observed, and physical interpretation revealed the uncertainty of prevailing athermal equations. A pilot sample was made to check our results and thermo-optical stress was assessed using an interferometer after isothermal load. This study presented insight into preliminary design guidance in elastomeric lens mounting.