• 제목/요약/키워드: thickness evaluation

검색결과 1,812건 처리시간 0.024초

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test

  • Bayarchimeg, Dorjpalam;Namgoong, Hee;Kim, Byung Kook;Kim, Myung Duk;Kim, Sungtae;Kim, Tae-Il;Seol, Yang Jo;Lee, Yong Moo;Ku, Young;Rhyu, In-Chul;Lee, Eun Hee;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제43권1호
    • /
    • pp.30-36
    • /
    • 2013
  • Purpose: Implant stability at the time of surgery is crucial for the long-term success of dental implants. Primary stability is considered of paramount importance to achieve osseointegration. The purpose of the present study was to investigate the correlation between the insertion torque and primary stability of dental implants using artificial bone blocks with different bone densities and compositions to mimic different circumstances that are encountered in routine daily clinical settings. Methods: In order to validate the objectives, various sized holes were made in bone blocks with different bone densities (#10, #20, #30, #40, and #50) using a surgical drill and insertion torque together with implant stability quotient (ISQ) values that were measured using the Osstell Mentor. The experimental groups under evaluation were subdivided into 5 subgroups according to the circumstances. Results: In group 1, the mean insertion torque and ISQ values increased as the density of the bone blocks increased. For group 2, the mean insertion torque values decreased as the final drill size expanded, but this was not the case for the ISQ values. The mean insertion torque values in group 3 increased with the thickness of the cortical bone, and the same was true for the ISQ values. For group 4, the mean insertion torque values increased as the cancellous bone density increased, but the correlation with the ISQ values was weak. Finally, in group 5, the mean insertion torque decreased as the final drill size increased, but the correlation with the ISQ value was weak. Conclusions: Within the limitations of the study, it was concluded that primary stability does not simply depend on the insertion torque, but also on the bone quality.

에폭시수지계 중성자 차폐재의 제조 및 방사선 차폐능 평가 (Fabrication and Evaluation of Radiation Shielding Property of Epoxy Resin-Type Neutron Shielding Materials)

  • 조수행;윤정현;최병일;도재범;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.77-83
    • /
    • 1997
  • 사용 후 핵연료 수송용기 등에 사용되는 에폭시수지계 중성자 차폐재, KNS(Kaeri Neutron Shield)-101, KNS-102 및 KNS-103를 제조하였다. 기본물질은 에폭시수지이며, 첨가제로는 폴리프로필렌, 수산화알루미늄 및 탄화붕소이다. 이들 중성자 차폐재들은 유동성이 좋아 수송용기와 같은 복잡한 구조에 사용할 수 있다. 제조된 중성자 차폐재들을 가압경수로 사용 후 핵연료 28다발을 수송할 수 있는 수송용기에 적용하여 차폐능 평가를 수행하였다. 세가지 중성자 차폐재를 수송용기에 적용하여 ANISN 코드로 차폐능 평가를 수행한 결과 정상수송시 중성자 차폐재의 두께가 10 cm 이상 일때 수송용기 반경방향표면에서 최대 방사선량율은 $300{\mu}Sv/h$로 나타났으며, 수송용기 표면에서 100 cm 지점에서의 최대 방사선량율은 $97{\mu}Sv/h$로 나타났다. 이들은 모두 관련된 법규들에서 규정된 최대허용 방사선량율을 만족하는 것으로 나타났다.

  • PDF

중온 아스팔트 혼합물의 성능 평가를 위한 아스팔트 바인더와 골재 사이의 접착물성분석 방법에 관한 연구 (A Study on the Performance Evaluation Method of Warm-mix Asphalt Mixture by the Analysis of Bonding Properties between Asphalt Binder and Aggregate)

  • 유인상;조동우;황성도;이석근
    • 대한토목학회논문집
    • /
    • 제31권6D호
    • /
    • pp.803-810
    • /
    • 2011
  • 국내외적으로 지구 온난화와 에너지 절약에 관한 관심이 커지고 있는 가운데 아스팔트관련 산업에서도 이러한 친환경 소재 및 기술 개발에 관심을 가지고 있다. 기존 가열 아스팔트에 비해 낮은 온도에서 생산할 수 있는 기술인 중온 아스팔트는 이러한 친환경 소재관련 기술 개발의 결과로서 지속적인 개발연구의 대상이 된다. 이러한 연구대상중의 하나는 중온 아스팔트 바인더의 접착능력을 측정하는 것이다. 그리고 또한 이러한 접착능력 평가와 아스팔트 혼합물 성능을 직접 연결하는 노력도 필요하다. 본 논문은 중온 아스팔트 바인더와 골재의 접착능력에 관한 내용을 다루고 있고, 그 접착능력을 평가하기 위한 시험방법을 제시하고 있다. 본 연구에서는 기존 DSR 수분손상시험을 사용해 가열 및 중온 아스팔트 바인더와 골재사이 접착부분의 물성을 비교 평가했고, 또한 아스팔트 혼합물 성능과의 관계성을 구하기 위해 인장강도 비를 측정해서 확인해 보았다. 본 연구를 통해서 나온 결론은 다음과 같다. 기존의 수퍼페이브 표준 아스팔트 바인더 시험법에서 사용하는 선형점탄성 $G^*$ 값보다는 85% 선형점탄성 $G^*$에서의 전단응력 값이 가열 아스팔트 바인더 또는 중온 아스팔트 바인더와 골재의 접착성을 좀 더 적확하게 평가하기 위한 물성 값이 될 수 있다. 그리고 얇은 아스팔트 피막두께의 접착능력을 평가하는 것이 실재 아스팔트 바인더와 골재의 접착능력을 좀 더 잘 반영할 수 있는 방법이 될 것이다.

거세한우 비육후기 농후사료 에너지 수준이 육질 및 경제성에 미치는 영향 (Effects of Energy Level of Concentrate Feed on Meat Quality and Economic Evaluation in Finishing Hanwoo Steers)

  • 백봉현;홍성구;권응기;조원모;유영모;신기준
    • Journal of Animal Science and Technology
    • /
    • 제47권3호
    • /
    • pp.447-456
    • /
    • 2005
  • This study was conducted to evaluate the effects of energy level of concentrate feed in finishing Hanwoo steers for 6 months before slaughter. Feeding trial was done with 2 treatment groups, IDN72 (72% of TDN in concentrate) and TDN74 (74 % of TDN in concentrate). The body weight (from 19 to 24 months) tended to be higher in TDN74 than in TDN72, but was not significant. Average daily gain of TDN74 was higher by 4.4 % in comparison to TDN72. There was no significant differences in concentrate, dry matter and TDN intake per I kg body weight gain between TDN72 and TDN74. And there was a tendency to improve crude protein intake per I kg body weight gain by increasing TDN content from 72 to 74 %. The dressing percentage tended to be higher in TDN74 than in TDN72, but was not significant. Salable meat percentage tended to be lower in TDN74 than in TDN72 because of higher body fat percentage in TDN74 than in TDN72. There were no significant differences in marbling score, meat color, fat color, carcass weight, rib-eye area and back fat thickness between TDN72 and TDN74. Significant differences were not found in shear value, cooking loss, water holding capacity or moisture and protein contents of longissimus dorsi (LD) muscles between TDN72 and TDN74. Fat content of LD muscles tend to be lower in TDN74 than in IDN72 but without any significance. There was a tendency to improve juiciness and taste by feeding IDN74 rather than TDN72. Especially, tenderness of TDN74 was increased by 7.4% in comparison to TDN72 (p < 0.05). Gross income from TDN74 was higher than TDN72 by 5% The results suggested that significant differences were not found in growth performance, feed conversion and carcass characteristics between TDN72 and TDN74. The results also show that more studies are required to clarify the energy level for finishing Hanwoo steers.

H2O2/HCl 처리한 Ti 임플란트의 생체활성 평가 (Evaluation of Bioactivity of Titanium Implant Treated with H2O2/HCl Solution)

  • 유재선;권오성;이오연;이민호;송기홍
    • 한국재료학회지
    • /
    • 제15권5호
    • /
    • pp.353-360
    • /
    • 2005
  • Surface treatment play an important role in nucleating calcium phosphate deposition on surgical Ti implant. Therefore, the purpose of this study is to examine whether the precipitation of apatite on cp-Ti and Ti alloys are affected by surface modification in HCl and $H_2O_2$ solution. Specimens were then chemically treated with a solution containing 0.1 M HCl and 8.8M $H_2O_2$ at $80^{\circ}C$ for 30 mins, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface was examined with XRD, SEM, EDX ana XPS. Also, pure Ti, Ti-6Al-4V and Ti-6Al-7Nb alloy specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. All specimens chemically treated with HCl and $H_2O_2$ solution have the ability to form a apatite layer in the HBSS which has inorganic ion composition similar to human blood plasma. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $38.57\;{\mu}m,\;62.27\;{\mu}m\;and\;45.64\;{\mu}m$ in the cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloy specimens with the chemical treatment respectively, and $52.20\;{\mu}m,\;75.62\;{\mu}m\;and\;66.56\;{\mu}m$ in the commercial specimens of cp-Ti, Ti-6Al-4V and Ti-6Al-7Nb without any treatment respectively. The results of this evaluation indicate that the chemically treated cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloys have better bioactivity and biocompatibility compared to the other metals tested.

유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰 (Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography)

  • 양한준;주미화;고신관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.113-119
    • /
    • 2007
  • 인체의 유방은 조직 간의 엑스선 흡수차가 작기 때문에 엑스선관 Target/Filter의 적절한 조합으로 피사체의 대 조도를 높이는 일이 중요하다. 최근 장비들은 다양한 유방두께와 유선조직 밀도에 따라서 Target/Filter의 조합을 변화시켜 환자의 피폭 선량 경감 및 진단에 알맞는 화질을 얻고 있다. 본 실험은 Target/Filter의 조합에 따라 해상력 챠트를 이용하여 MTF 영상의 평가와 유방 팬톰 영상을 평가하여 다음과 같은 결론을 얻었다. 1. 아크릴 두께(2 cm, 3 cm, 4 cm)의 조합(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al)에 따라 고유원자번호에 의해 엑스선 에너지에서 큰 차이를 보였다. 2. MTF 곡선에서 선예도를 나타내는 MTF 0.5에서의 Lp/mm 값은 아크릴 2 cm일 때 Mo/Mo은 2.4 Lp/mm, 4 cm일 때 Mo/Rh은 2.63 Lp/mm, 6 cm일 때 Rh/Rh은 2.9 Lp/mm로 높게 나타났다. 3. 분해능을 나타내는 MTF 값은 아크릴 2 cm일 때 Mo/Mo은 6.0 Lp/mm, 4cm일 때 Rh/Al은 4.60 Lp/mm, 6 cm일 때 Rh/Al은 6.03 Lp/mm로 MTF 값이 높게 나타났다. 4. 시각적 식별이 가능한 2.5 Lp/mm에서 MTF 값은 2 cm일 때 Mo/Mo은 0.48 Lp/mm, 4 cm일 때 Mo/Rh은 0.53 Lp/mm, 6 cm일 때 Rh/Rh은 0.59 Lp/mm로 높게 나타났다. 5. 유방 팬톰 영상평가에서는 Mo/Mo일 때 12점, Mo/Rh일 때 11점, Rh/Rh일 때 10.5점, Mo/Al일 때 10점, Rh/Al일 때 9점 순으로 나타났다.

  • PDF

자기공명영상 화질 평가용 팬텀 개발에 관한 연구 (Development of MRI Phantom for Assessing MR Image Quality)

  • 안창범;나동규;김광기;김동성;김인수;이정휘;홍석주;변재호;강현수;장기원;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.89-97
    • /
    • 2006
  • 목적 : 자기공명영상 화질을 평가하는 팬텀으로서 코일 장착도구가 내장된 새로운 형태의 팬텀을 개발하였다. 대상 및 방법 : 자기공명영상 화질평가항목인 절편 두께 정확도, 공간 분해능, 대조도 분해능, 기하학적 정확도, 절편 위치 정확도, 영상강도 균일성, 고스트 신호 백분율, 신호대잡음비 등 총 8개의 사양을 가진 팬텀을 고안하였다. 팬텀의 코일 장착을 위한 장치가 팬텀 표면에 설치 되었다. 개발된 팬텀의 임상적용가능성을 알아보기 위하여 6개의 다른 종류의 자기공명영상기기를 사용하여 영상을 습득하였고 이들 화질이 평가되었다. 결과 : 사용된 모든 자기공명영상기기에서 영상평가에 문제가 없는 영상을 보여주었고 그들의 평가결과는 일부 평가항목에서 실측치와 비교하여 적절한 값 범위에 있음을 확인하였다. 코일장착도구를 사용하여 팬텀을 두부용 코일 안에 설치하는 데 문제가 없음을 확인하였다. 결론 : 본 논문에서 개발된 팬텀은 자기공명영상 화질을 평가하는 데 있어 그 임상적용 가능성이 있음을 보여주었다.

  • PDF

단감분말 첨가 유형에 따른 저염 미트패티제품의 저온저장 중 품질특성 (Effects of Sweet Persimmon Powder Type on Quality Properties of Low Salted Pork Patties during Cold Storage)

  • 김일석;진상근;하창주
    • Journal of Animal Science and Technology
    • /
    • 제50권1호
    • /
    • pp.133-144
    • /
    • 2008
  • 미트패티 제품에 열풍건조 단감분말(HP)과 동결건조 단감분말(FP)을 각각 3%(HP-3%, FP- 3%)와 6%(HP-6%, FP-6%)를 첨가하여 제조한 후 폴리비닐랩으로 포장한 후 4℃에 저장하였다. 수분함량은 대조구와 HP-3%가 다른 처리구에 비하여 유의적으로 높았으며(p<0.05), 조단백질 함량은 FP-6%, 조지방 함량은 FP-3% 처리구가 다른 처리구에 비하여 높았으며, 조회분 함량은 유의적인 차이가 없었다(p>0.05). 저장기간이 경과함에 따라 pH, L* 및 a*값은 모든 처리구에서, 보수력은 CTL와 HP-6%, 가열감량은 HP-3%에서 유의적으로 감소하였다(p< 0.05). 미트패티의 직경과 두께는 저장기간이 경과함에 따라 감소하였다. VBN은 저장기간이 경과함에 따라 모든 제품에서 증가하였다(p<0.05). 처리구들의 TBARS는 저장 전 기간 동안 CTL보다 유의적으로 높았다(p<0.05). 저장 8일까지 총균수는 4.61 log10 CFU/g 수준을 유지하였다. 관능검사결과, 향과 풍미, 육색 및 전체적인 기호도는 처리구가 더 좋은 점수를 얻었다(p<0.05).

폴리프로필렌의 변형속도 및 온도변화에 따른 판재 인장시험 평가 (Tensile Test Evaluation of Polypropylene Sheets Following as Strain Rate and Temperature Variation)

  • 김기주
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.32-36
    • /
    • 2018
  • 500kgf 용량의 Instron 시험기를 이용하여 폴리프로필렌 판재의 인장시험 평가를 행하였다. 두께가 0.8 mm인 폴리프로필렌 판재의 변형속도민감도를 평가하기 위하여 변형속도는 $5{\times}10^{-4}/sec{\sim}5{\times}10^{-2}/sec$으로 100배 변화를 주어 상온 및 고온인장시험 하였다. 이를 통하여 변형속도 및 온도 변화에 따른 강도변화를 비교하였다. 실험결과 초기 변형속도가 증가할수록 강도가 증가하였으며 이는 폴리프로필렌은 변형속도민감도가 강한 양의 값을 지닌 재료임을 알 수 있었다. 또한 폴리프로필렌 판재의 고온 인장특성을 평가하기 위하여 온도는 80, 120, $160^{\circ}C$로 변화시켜 시험하였다. 고온인장시험 결과 온도가 증가할수록 강도는 감소하였으며 특히 $160^{\circ}C$에서는 강도가 인장강도가 0으로 강하하였다. 변형속도 증가에 따른 온도 증가의 영향을 살펴보면 상온, $80^{\circ}C$$120^{\circ}C$까지는 항복강도 및 인장강도의 증가 폭이 비슷한 수준을 나타내었으나 $160^{\circ}C$에서는 응력이 0에 가까워짐에 따라 강도 증가가 거의 없는 것으로 나타났다. 고온 인장시험에서 변형속도 증가에 따라 항복강도 값이 증가하는 양 보다는 인장강도 값이 증가하는 폭이 컸다.