• 제목/요약/키워드: thickness evaluation

검색결과 1,812건 처리시간 0.033초

The Potential Substitution of Oyster Shell Powder for Phosphate in Pork Patties Cured with Chinese Cabbage and Radish Powder

  • Su Min Bae;Jong Youn Jeong
    • 한국축산식품학회지
    • /
    • 제44권4호
    • /
    • pp.849-860
    • /
    • 2024
  • The use of natural ingredients in meat processing has recently gained considerable interest, as consumers are increasingly attracted to clean-label meat products. However, limited research has been conducted on the use of natural substitutes for synthetic phosphates in the production of clean-label meat products. Therefore, this study aimed to explore the potential of oyster shell powder as a substitute for synthetic phosphates in pork patties cured with Chinese cabbage or radish powders. Four different groups of patties were prepared using a combination of 0.3% or 0.6% oyster shell powder and 0.4% Chinese cabbage or radish powder, respectively. These were compared with a positive control group that contained added nitrite, phosphate, and ascorbate and a negative control group without these synthetic ingredients. The results showed that patties treated with oyster shell powder had lower (p<0.05) cooking loss, thickness and diameter shrinkage, and lipid oxidation than the negative control but had lower (p<0.05) residual nitrite content and curing efficiency than the positive control. However, the use of 0.6% oyster shell powder adversely affected the curing process, resulting in a decreased curing efficiency. The impact of the vegetable powder types tested in this study on the quality attributes of the cured pork patties was negligible. Consequently, this study suggests that 0.3% oyster shell powder could serve as a suitable replacement for synthetic phosphate in pork patties cured with Chinese cabbage or radish powders. Further research on the microbiological safety and sensory evaluation of clean-label patties during storage is required for practical applications.

Hysteroscopic evaluation of endometrial changes and fallopian tubal functions in women using progestin-only contraceptives

  • Atef Darwish;Ibrahim Mohammad;Samuel Gendy;Dina Darwish;Mohammad Ramdan
    • Journal of Medicine and Life Science
    • /
    • 제21권2호
    • /
    • pp.21-30
    • /
    • 2024
  • The purpose of this prospective study was to investigate whether office hysteroscopy (OH) can be used to assess the mechanisms of action of progestogen-only contraceptives (POCs), diagnose possible local causes of abnormal uterine bleeding (AUB), and support the treatment plan of symptomatic patients using POCs compared with those who do not use hormones. The study included 140 women who were divided into two groups. Group A consisted of 70 women who used POCs, whereas group B consisted of 70 women who did not use hormones. They were successively examined using transvaginal ultrasonography (TVS), OH, and endometrial sampling. The TVS results were consistent with those of OH and histopathology. The changes in endometrial thickness and vasculature, as well as fallopian tube (FT) functions, were significantly more pronounced in POC users than in non-POC users. There was a significant reduction in the peristalsis of the proximal part of the FT, as well as a reduction in the bubble flow test in group A compared with group B. In addition, the combination of peristalsis and the bubble flow test (Darwishscope test) was significantly lower in group A. It was concluded that using OH as a simple diagnostic tool in women with POCs would contribute to a better understanding of the mechanisms of endometrial and FT effects and explain some local endometrial causes of AUB. This ensures that the combination of TVS and OH would limit routine endometrial sampling in POCs users.

등온 시효 처리에 따른 Cu Pillar Bump 접합부 특성 (Properties of Cu Pillar Bump Joints during Isothermal Aging)

  • 장은수;노은채;나소정;윤정원
    • 마이크로전자및패키징학회지
    • /
    • 제31권1호
    • /
    • pp.35-42
    • /
    • 2024
  • 최근 반도체 칩의 소형화 및 고집적화에 따라 미세 피치에 의한 범프 브리지 (bump bridge) 현상이 문제점으로 주목받고 있다. 이에 따라 범프 브리지 현상을 최소화할 수 있는 Cu pillar bump가 미세 피치에 대응하기 위해 반도체 패키지 산업에서 널리 적용되고 있다. 고온의 환경에 노출될 경우, 접합부 계면에 형성되는 금속간화합물(Intermetallic compound, IMC)의 두께가 증가함과 동시에 일부 IMC/Cu 및 IMC 계면 내부에 Kirkendall void가 형성되어 성장하게 된다. IMC의 과도한 성장과 Kirkendall void의 형성 및 성장은 접합부에 대한 기계적 신뢰성을 약화시키기 때문에 이를 제어하는 것이 중요하다. 따라서, 본 연구에서는 CS(Cu+ Sn-1.8Ag Solder) 구조 Cu pillar bump의 등온 시효 처리에 따른 접합부 특성 평가가 수행되었으며 그 결과가 보고되었다.

PC 접합부의 실물 성능실험을 통한 기계식이음 구조성능 평가 (Evaluation of Mechanical Joint Structural Performance through Actual Performance Testing of PC Connections)

  • 김재영;김용남;서민정;김범진;김승직;이기학
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.129-139
    • /
    • 2024
  • In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.

The analysis of tissue elasticity using computer-controlled ultrasonography in the affected upper limb of patients after breast cancer surgery

  • Chan-Hyuk Kwon;Min Woo Ha
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권6호
    • /
    • pp.167-173
    • /
    • 2024
  • 본 연구에서는 컴퓨터로 제어되는 초음파를 이용하여 피하 조직의 탄성도를 도출할 수 있는 방법을 개발하였다. 림프 부종은 유방암 수술에서 흔한 합병증으로 유방암 생존자에 있어 삶의 질을 저하시키는 주요 원인으로 알려져 있다. 그러나 아직 부종 조직의 성상을 정량적으로 분석할 수 있는 방법은 정립되어 있지 않다. 유방암 수술 이후 한 쪽 상지에 부종으로 인한 불편감을 호소하는 환자를 대상으로 총 30례의 부종 조직과 그에 상응하는 정상 조직에서의 초음파 분석을 수행하였고, 건측과 환측 간 탄성도의 차이를 도출하였다. 그에 따라 차이가 음수인 더 딱딱한 그룹과(n=13) 양수인 더 부드러운 그룹으로(n=17) 분류하였다. 컴퓨터 제어 초음파 검사와 실시간 압력 센서를 이용한 피하 조직 탄력성 평가는 유방암 수술 후 발생한 림프 부종 환자에서 조직의 성상을 분석할 수 있는 유용한 도구가 될 것이다.

Impingement wastage experiment with SUS 316 in a printed circuit steam generator

  • Siwon Seo;Bowon Hwang;Sangji Kim;Jaeyoung Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.257-264
    • /
    • 2024
  • The sodium cooled fast reactor (SFR) is one of the Gen-IV reactors with the most operating experience accumulated. Although the technology level is the most mature among the Gen-IV reactors, there is still a safety problem that has not been solved, which is the sodium-water reaction. Since sodium and water are separated only by a heat transfer tube with a thickness of only a few mm, there is inherently a risk of a sodium-water reaction (SWR) accident in the SFR. In this study, it is attempted to quantitatively evaluate the resistance of SWR accidents by replacing the shell and tube steam generator with printed circuit steam generator (PCSG) as a method to mitigate the SWR accident. To do this, a CATS-S (Compact Accident Tolerance Steam Generator-SWR) facility was designed and built. And for the quantitative evaluation of accident resistance, a methodology for measuring the impingement wastage rate was established. As a result of this research, the impingement wastage rate caused by SWR generated in a PCSG was measured first time. It was confirmed that the impingement wastage phenomenon was suppressed in the PCSG, and the accident resistance was higher than that of the SWR through comparison with the experimental results performed in the existing shell and tube steam generator. In conclusion, a PCSG is more resistant to impingement wastage as a result of the SWR accident than existing shell and tube steam generators, and it is estimated that a PCSG can mitigate SWR accidents, an inherent problem of SFR.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

National Genetic Evaluation (System) of Hanwoo (Korean Native Cattle)

  • Park, B.;Choi, T.;Kim, S.;Oh, S.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권2호
    • /
    • pp.151-156
    • /
    • 2013
  • Hanwoo (Also known as Korean native cattle; Bos taurus coreanae) have been used for transportation and farming for a long time in South Korea. It has been about 30 yrs since Hanwoo improvement began in earnest as beef cattle for meat yield. The purpose of this study was to determine the trend of improvement as well as to estimate genetic parameters of the traits being used for seedstock selection based on the data collected from the past. Hanwoo proven bulls in South Korea are currently selected through performance and progeny tests. National Hanwoo genetic evaluations are implemented with yearling weight (YW), carcass weight (CW), eye muscle area (EMA), backfat thickness (BF) and marbling score (MS). Yearling weights and MS are used for selecting young bulls, and EMA, BF, and MS are used for selecting proven bulls. One individual per testing room was used for performance tests, and five individuals per room for progeny tests. Individuals tested were not allowed to graze pasture, but there was enough space for them to move around in the testing room. Feeds including roughages and minerals were fed ad libitum, and concentrates were provided at the rate of about 1.8% of individual weight. Overall means of the traits were $352.8{\pm}38.56$ kg, $335.09{\pm}44.61$ kg, $77.85{\pm}8.838\;cm^2$, $8.6{\pm}3.7$ mm and $3.293{\pm}1.648$ for YW, CW, EMA, BF and MS. Heritabilities estimated in this study were 0.30, 0.30, 0.42, 0.50 and 0.63 in YW, CW, EMA, BF and MS, respectively, which are similar to results from previous research. Yearling weight was 315.54 kg in 1998, and had increased to 355.06 kg in 2011, resulting in about 40 kg of improvement over 13 yrs. YW and CW have improved remarkably over the past 15 yrs. Breeding values between 1996 and 2000 decreased or did not change much, but have moved in a desirable direction since 2001. These improvements correspond with the substantial increase in use of animal models since the late 1990s in Korea. Hanwoo testing programs have practically contributed to the improvement in aspects of quality and quantity. In sum, the current selection system is good enough to accommodate circumstances where fewer sires are used on many more cows. Although progeny tests take longer and cost more, they seem to be appropriate under the circumstances of the domestic market with its higher requirement for better meat quality. Consequently, accumulative data collection, genetic evaluation model development, revision of selection indices, as well as cooperation among farms, associations, National Agricultural Cooperative Federation, universities, research institutes, and government agencies must be applied to the Hanwoo selection program. All these efforts will assist the domestic market to secure a competitive position against imported beef under Free Trade Agreement trade system and will provide farmers with higher profits as well as the public with a higher quality of beef.

보행하중에 대한 2방향 중공슬래브의 진동성능 평가 (Performance Evaluation of Floor Vibration of Biaxial Hollow Slab Subjected to Walking Load)

  • 김민균;박현재;이동근;황현식;김현수
    • 한국지진공학회논문집
    • /
    • 제13권5호
    • /
    • pp.11-21
    • /
    • 2009
  • 2방향 중공슬래브 시스템은 슬래브 두께가 증가해도 자중은 크게 증가하지 않으면서 솔리드 슬래브에 비해서 휨강성이 크게 저하되지 않는 장점이 있다. 따라서 최근 넓은 바닥판 구조에 대한 수요가 커지면서 2방향 중공슬래브 시스템에 대한 관심이 증가하고 있다. 그러나 이러한 장스팬 구조의 경우 바닥판 진동의 증가에 의한 사용성에 문제가 발생할 수 있고 특히 2방향 중공슬래브의 경우 기존의 구조시스템과 동적특성이 상이하다. 따라서 본 연구에서는 기존의 라멘조 시스템과 2방향 중공슬래브 시스템의 바닥진동성능을 보행하중을 가하여 검토해 보았다. 본 연구에서는 해석의 효율성을 위하여 2방향 중공슬래브의 동적특성을 정확히 나타낼 수 있는 등가의 플레이트 모델을 사용하여 시간이력해석을 수행하였다. 해석결과를 바탕으로 일본건축학회와 미국표준협회에서 제안하는 진동성능평가 기준을 이용하여 진동성능 평가를 수행한 결과 2방향 중공슬래브가 사무실 수준의 진동성능을 만족하고 있는 것으로 나타났다.

근적외선 형광 이미징 영상 구현을 위한 다채널 필터 모듈 특성분석 연구 (A Study on Characteristics Analysis of Multichannel Filter Module for Near-infrared Fluorescence Imaging)

  • 최진수;조상욱;김두인;이학근;최학수;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2016
  • 본 연구에서는 생체 영상 이미징을 위한 다채널 필터 모듈 개발 및 특성 평가 연구를 수행하였다. 필터 모듈은 700 nm 및 800 nm 파장대의 근적외선 형광 이미징을 동시에 구현할 수 있도록 제작되었으며, 모듈의 특성 평가를 위해 magnification, exposure, gain의 변수에 따른 signal to back ground ratio (SBR)을 통한 대조영상 평가를 진행하였다. 또한 생체 영상 분석을 위해 신장 및 간의 광학적 특성이 동일한 생체 모사 조직인 phantom을 제작하여 두께에 따른 필터 모듈의 특성 및 광원의 주입량에 따른 특성 연구를 진행하였다. 제작된 필터 모듈은 magnification, exposure, gain의 변화에도 4이상의 SBR 차이를 보이며, kidney phantom 및 liver phantom의 경우 각각 50 mA, 60 mA의 광원 주입량에서 4이상의 SBR 대조 영상을 확인하였다.