• Title/Summary/Keyword: thickness evaluation

Search Result 1,817, Processing Time 0.03 seconds

Reaction Characteristics between In-l5Pb-5Ag Solder and Au/Ni Surface Finish and Reliability Evaluation of Solder Joint (In-l5Pb-5Ag 솔더와 Au/Ni Surface Finish와의 반응 특성 및 접합 신뢰성 평가)

  • 이종현;엄용성;최광성;최병석;윤호경;박흥우;문종태
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • The metallurgical reaction properties between the pad consisted of 0.5 $\mu\textrm{m}$Au/5 $\mu\textrm{m}$Ni/Cu layers on a conventional ball grid array (BGA) substrate and In-15 (wt.%)Pb-5Ag solder ball were characterized during the reflow process and solid aging. During the reflow process of 1 to 5 minutes, it was observed that thin $AuIn_2$ or Ni-In intermetallic layer was formed at the interface of solder/pad. The dissolution rate of the Au layer into the molten solder was about $2\times 10^{-3}$ $\mu\textrm{m}$/sec which is remarkably low in comparison with a eutectic Sn-37Pb solder. After solid aging treatment for 500 hrs at $130^{\circ}C$, the thickness of $Ni_{28}In_{72}$ intermetallic layer was increased to about 3 $\mu\textrm{m}$ in all the conditions nevertheless the initial reflow time was different. These result show that In atoms in the solder alloy were diffused through the $AuIn_2$ phase to react with underlaying Ni layer during solid aging treatment. From the microstructural observation and shear tests, the reaction properties between In-15Pb-5Ag alloy and Au/Ni surface finish were analyzed not to trigger Au-embrittlement in the solder joints unlike Sn-37Pb composition.

  • PDF

Drop reliability evaluation of Sn-3.0Ag-0.5Cu solder joint with OSP and ENIG surface finishes (OSP.ENIG 표면 처리된 기판과 Sn-3.0Ag-0.5Cu 솔더 접합부의 낙하충격 신뢰성 평가)

  • Ha, Sang-Ok;Ha, Sang-Su;Lee, Jong-Bum;Yoon, Jeong-Won;Park, Jai-Hyun;Chu, Yong-Chul;Lee, Jun-Hee;Kim, Sung-Jin;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2009
  • The use of portable devices has created the need for new reliability criterion of drop impact tests because of the tendency to accidentally drop in the use of these devices. The effects of different PCB surface finishes (organic solderability preservative (OSP) and electroless nickel immersion gold (ENIG)) and high temperature storage (HTS) test on the drop reliability were studied. Various drop test conditions were used to evaluate a drop reliability of assemblies to endure such impact and shock load. In the case of the as-reflowed samples (no HTS test), the SAC/OSP boards exhibited a better drop impact reliability than that of SAC/ENIG. However, the reverse was true if HTS test is performed. In addition, significant decrease of drop reliability was observed for both SAC/ENIG and SAC/OSP assemblies after HTS test. It was also observed that the thickness of intermetallic compound layer do play an important role in the brittle fracture of drop test.

  • PDF

Development of the computer program calculating the stress induced by various loads for buried natural gas pipeline (II) (매설 천연가스 배관의 제반하중에 의한 응력 계산용 프로그램 개발 (II))

  • Bang I.W.;Kim H.S.;Yang Y.C.;Kim W.S.;Oh K.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.26-33
    • /
    • 1998
  • The thickness of buried gas pipeline is determined mainly with internal pressure and location factor according to the requirements of ANSI B3l.8. But the stress of buried gas pipeline is determined by not only internal stress but also external loads. The change of burying and environmental conditions, therefore, may result in increasing stress of pipeline. In order to avoid the decrease of safety degree resulting from change of environmental condition, the evaluation of stress level shall be necessary. The reliable equations have been developed for calculating stress of buried pipeline from internal pressure, earth load, vehicle load, ground subsidence. But they are very difficult to understand and use for non-specialist. For easy calculation of non-specialist, the new computer program to calculate stress of buried natural gas pipeline have been developed. The program can calculate maximum stress resulted from earth load, vehicle load, thermal load, four type ground subsidence. The stress is calculated by the equations and extrapolation of the graph resulted from FEM. In this paper, as the series of paper I, the operating method and the functions of the program is explained.

  • PDF

Classification of Ground Subsidence Factors for Prediction of Ground Subsidence Risk (GSR) (굴착공사 중 지반함몰 위험예측을 위한 지반함몰인자 분류)

  • Park, Jin Young;Jang, Eugene;Kim, Hak Joon;Ihm, Myeong Hyeok
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.153-164
    • /
    • 2017
  • The geological factors for causing ground subsidence are very diverse. It can be affected by any geological or extrinsic influences, and even within the same geological factor, the soil depression impact factor can be determined by different physical properties. As a result of reviewing a large number of papers and case histories, it can be seen that there are seven categories of ground subsidence factors. The depth and thickness of the overburden can affect the subsidence depending on the existence of the cavity, whereas the depth and orientation of the boundary between soil and rock are dominant factors in the ground composed of soil and rock. In case of soil layers, more various influencing factors exist such as type of soil, shear strength, relative density and degree of compaction, dry unit weight, water content, and liquid limit. The type of rock, distance from the main fracture and RQD can be influential factors in the bedrock. When approaching from the hydrogeological point of view, the rainfall intensity, the distance and the depth from the main channel, the coefficient of permeability and fluctuation of ground water level can influence to ground subsidence. It is also possible that the ground subsidence can be affected by external factors such as the depth of excavation and distance from the earth retaining wall, groundwater treatment methods at excavation work, and existence of artificial facilities such as sewer pipes. It is estimated that to evaluate the ground subsidence factor during the construction of underground structures in urban areas will be essential. It is expected that ground subsidence factors examined in this study will contribute for the reliable evaluation of the ground subsidence risk.

Interaction between Nutrient Density Diets and Sex on Carcass and Quality Characteristics in Finishing Pigs (사료의 영양소 수준과 성별이 도체 및 육질특성에 미치는 영향)

  • Ha, Y.J.;Lee, J.I.;Lee, J.Y.;Lee, J.W.;Jung, J.D.;Kwack, S.J.;Song, Y.M.;Do, C.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.57-72
    • /
    • 2005
  • The present study was undertaken to investigate the effects of nutrient density diets and sex on carcass and pork quality characteristics in finishing pigs. A total of 96 pigs(58.04 $\pm$ 6.85 kg) were divided into 2 groups(gilts and barrows), each sex group was assigned to 3 nutrient density(high : 18.5%, middle : 16.0% and low: 14.0% CP, respectively) and raised up to 1l0kg live weight. Each treatment had four replicates with three or five pigs per replicate. The treatments comprised the feeding regimes of 1) the low density diet for 60 days, 2) the middle nutrient density diet for the 30 days followed by a low nutrient density diet for the remaining 30 days and 3) the high nutrient density diet for the 30 days followed by a middle nutrient density diet for the remaining 30 days. Pigs were conventionally slaughtered, and then chilled overnight. Carcass characteristics and grades were determined on those carcasses, and pork loin muscle was removed from each left side at 5th to 13th rib for quality evaluation were evaluated. There were no differences in the carcass weight between sex and nutrient density. Dressing percent of L-L(gilts) treatment was significantly higher than that of other treatments(P< 0.05). Barrows showed a thicker back fat thickness than gilts. There were no difference in intramuscular fat, subcutaneous fat and springiness between sex and nutrient density. Intermuscular fat of barrows groups was significantly higher than the gilts groups(P < 0.05). In the meat quality characteristics, there were no difference in general composition, meat and fat color between sex and nutrient density. pH of L-L(gilts) treatment was significantly higher than that of other treatments(P < 0.05). Cooking loss and shear force value of H-M(barrows) treatment were significantly higher than those of other treatments(P< 0.05). Purge loss of barrows groups was significantly higher than the gilts groups(P < 0.05). Myoglobin content of H-M treatment was significantly lower than L-L and M-L treatments(P< 0.05). Texture of H-M treatment was higher than L-L and M-L treatments. The content of myristic, palmitic, palmitoleic and oleic acid were significantly higher in the barrows groups(P< 0.05). However, stearic, linoleic and arachidonic acid were significantly higher in the gilts(P < 0.05). Amino acid content of L-L treatment was significantly higher than M-L and H-M treatments(P < 0.05). In conclusion, carcass and pork quality characteristics were affected by sex and nutrient density.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection (머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구)

  • Lee, Cho-Hee;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3117-3122
    • /
    • 2011
  • Skull A-P projections are the bi-product where the ESD (Entrance Surface Dose) for digital radiography is much higher than that conventional screen-film radiography. Therefore, the aim of this study was to reduce radiation doses to patients by using an added filter. This research focuses on the identification of the reduction of exposure to radiation based on the thickness of an added filter when applying the 'Skull A-P Projection' by using the 'Skull Phantom'. Also, an experiment was conducted to evaluate the qualitative decline of images through filtration. The measurement of one's exposed dose to radiation was executed by locating the 'Skull Phantom' on the position of the 'Skull AP,' while changing 16 kinds of added filters from 0.1 mmAl to 0.5 mmCu + 2.0 mmAl in terms of incident and penetrating doses. For the qualitative evaluation of images, a total number of 17 images have been acquired in the 'Skull Phantom' under the same conditions as those for the measurement of one's exposed dose. The acquired images have been evaluated by a radiological specialist. As a result, the images with a diagnostic value have been obtained by using such added filters as the compound filter of 0.2 mmCu +1.0 mmAl. The exposed dose absorbed on the 'Skull Phantom' is about 0.6 mGy. The value is only 12% of 5 mGy, the ESD value acquired on the 'Skull P-A Projection', which is recommended by the International Atomic Energy Agency (IAEA). As a result, depending on the parts of inspection, it is possible to reduce the patient's exposed dosage of radiation considerably by using an appropriate added filter.

The evaluation of surface roughness and polishing time between polishing systems (연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가)

  • Kim, Ye-Mi;Shin, Su-Jung;Song, Min-Ju;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.

Properties of liquid crystal alignment layers exposued to ion-beam irradiation enemies (이온빔 에너지에 따른 액정배향막의 전기광학적 특성연구)

  • Oh, Byeong-Yun;Lee, Kang-Min;Park, Hong-Gyu;Kim, Byoung-Yong;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.430-430
    • /
    • 2007
  • In general, polyimides (PIs) are used in liquid crystal displays (LCDs) as alignment layer of liquid crystals (LCs). Up to date, the rubbing alignment technique has been widely used to align liquid crystals on the PI surface, which is suitable for mass-production of LCDs because of its simple process and high productivity. However, this method has some disadvantages. Rubbed PI surfaces include the debris left by the cloth and the generation of electrostatic charges during rubbing process. Therefore, rubbing-free techniques for LC alignment are strongly required in LCD technology. In this experiment, PI was uniformly coated on indium-tin-oxide electrode substrates to form LC alignment layers using a spin-coating method and the PI layers were subsequently imidized at 433 K for 1 h. The thickness of the PI layer was set at 50 nm. The LC alignment layer surfaces were exposed to an $Ar^+$ ion-beam under various ion-beam energies. The antiparallel cells and twisted-nematic (TN) cells for the measurement of pretile angle and electro-optical characteristics were fabricated with the cell gap of 60 and $5\;{\mu}m$, respectively. The LC cells were filled with nematic LC (NLC, MJ001929, Merck) and were assembled. The NLC alignment capability on ion-beam-treated PI was observed using photomicroscope and the pretilt angle of the NLC was measured by the crystal-rotation method at room temperature. Voltage-transmittance (V-T) and response time characteristics of the ion-beam irradiated TN cell were measured by a LCD evaluation system.

  • PDF

Optical Monte Carlo Simulation on Spatial Resolution of Phosphor Coupled X-ray Imaging Detector (형광체 결합형 X선 영상검출기의 공간 해상력 몬테카를로 시뮬레이션)

  • Kang, Sang-Sik;Kim, So-Yeong;Shin, Jung-Wook;Heo, Sung-Wook;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.328-328
    • /
    • 2007
  • Large area matrix-addressed image detectors are a recent technology for x-ray imaging with medical diagnostic and other applications. The imaging properties of x-ray pixel detectors depend on the quantum efficiency of x-rays, the generated signal of each x-ray photon and the distribution of the generated signal between pixels. In a phosphor coated detector the light signal is generated by electrons captured in the phosphor screen. In our study we simulated the lateral spread distributions for phosphor coupled detector by Monte Carlo simulations. Most simulations of such detectors simplify the setup by only taking the conversion layer into account neglecting behind. The Monte Carlo code MCNPX has been used to simulate the complete interaction and subsequent charge transport of x-ray radiation. This has allowed the analysis of charge sharing between pixel elements as an important limited factor of digital x-ray imaging system. The parameters are determined by lateral distribution of x-ray photons and x-ray induced electrons. The primary purpose of this study was to develop a design tool for the evaluation of geometry factor in the phosphor coupled optical imaging detector. In order to evaluate the spatial resolution for different phosphor material, phosphor geometry we have developed a simulation code. The developed code calculates the energy absorption and spatial distribution based on both the signal from the scintillating layer and the signal from direct detection of x-ray in the detector. We show that internal scattering contributes to the so-called spatial resolution drop of the image detector. Results from the simulation of spatial distribution in a phosphor pixel detector are presented. The spatial resolution can be increased by optimizing pixel size and phosphor thickness.

  • PDF