• Title/Summary/Keyword: thickness evaluation

Search Result 1,812, Processing Time 0.027 seconds

The Potential Substitution of Oyster Shell Powder for Phosphate in Pork Patties Cured with Chinese Cabbage and Radish Powder

  • Su Min Bae;Jong Youn Jeong
    • Food Science of Animal Resources
    • /
    • v.44 no.4
    • /
    • pp.849-860
    • /
    • 2024
  • The use of natural ingredients in meat processing has recently gained considerable interest, as consumers are increasingly attracted to clean-label meat products. However, limited research has been conducted on the use of natural substitutes for synthetic phosphates in the production of clean-label meat products. Therefore, this study aimed to explore the potential of oyster shell powder as a substitute for synthetic phosphates in pork patties cured with Chinese cabbage or radish powders. Four different groups of patties were prepared using a combination of 0.3% or 0.6% oyster shell powder and 0.4% Chinese cabbage or radish powder, respectively. These were compared with a positive control group that contained added nitrite, phosphate, and ascorbate and a negative control group without these synthetic ingredients. The results showed that patties treated with oyster shell powder had lower (p<0.05) cooking loss, thickness and diameter shrinkage, and lipid oxidation than the negative control but had lower (p<0.05) residual nitrite content and curing efficiency than the positive control. However, the use of 0.6% oyster shell powder adversely affected the curing process, resulting in a decreased curing efficiency. The impact of the vegetable powder types tested in this study on the quality attributes of the cured pork patties was negligible. Consequently, this study suggests that 0.3% oyster shell powder could serve as a suitable replacement for synthetic phosphate in pork patties cured with Chinese cabbage or radish powders. Further research on the microbiological safety and sensory evaluation of clean-label patties during storage is required for practical applications.

Hysteroscopic evaluation of endometrial changes and fallopian tubal functions in women using progestin-only contraceptives

  • Atef Darwish;Ibrahim Mohammad;Samuel Gendy;Dina Darwish;Mohammad Ramdan
    • Journal of Medicine and Life Science
    • /
    • v.21 no.2
    • /
    • pp.21-30
    • /
    • 2024
  • The purpose of this prospective study was to investigate whether office hysteroscopy (OH) can be used to assess the mechanisms of action of progestogen-only contraceptives (POCs), diagnose possible local causes of abnormal uterine bleeding (AUB), and support the treatment plan of symptomatic patients using POCs compared with those who do not use hormones. The study included 140 women who were divided into two groups. Group A consisted of 70 women who used POCs, whereas group B consisted of 70 women who did not use hormones. They were successively examined using transvaginal ultrasonography (TVS), OH, and endometrial sampling. The TVS results were consistent with those of OH and histopathology. The changes in endometrial thickness and vasculature, as well as fallopian tube (FT) functions, were significantly more pronounced in POC users than in non-POC users. There was a significant reduction in the peristalsis of the proximal part of the FT, as well as a reduction in the bubble flow test in group A compared with group B. In addition, the combination of peristalsis and the bubble flow test (Darwishscope test) was significantly lower in group A. It was concluded that using OH as a simple diagnostic tool in women with POCs would contribute to a better understanding of the mechanisms of endometrial and FT effects and explain some local endometrial causes of AUB. This ensures that the combination of TVS and OH would limit routine endometrial sampling in POCs users.

Properties of Cu Pillar Bump Joints during Isothermal Aging (등온 시효 처리에 따른 Cu Pillar Bump 접합부 특성)

  • Eun-Su Jang;Eun-Chae Noh;So-Jeong Na;Jeong-Won Yoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Recently, with the miniaturization and high integration of semiconductor chips, the bump bridge phenomenon caused by fine pitches is drawing attention as a problem. Accordingly, Cu pillar bump, which can minimize the bump bridge phenomenon, is widely applied in the semiconductor package industry for fine pitch applications. When exposed to a high-temperature environment, the thickness of the intermetallic compound (IMC) formed at the joint interface increases, and at the same time, Kirkendall void is formed and grown inside some IMC/Cu and IMC interfaces. Therefore, it is important to control the excessive growth of IMC and the formation and growth of Kirkendall voids because they weaken the mechanical reliability of the joints. Therefore, in this study, isothermal aging evaluation of Cu pillar bump joints with a CS (Cu+ Sn-1.8Ag Solder) structure was performed and the corresponding results was reported.

Evaluation of Mechanical Joint Structural Performance through Actual Performance Testing of PC Connections (PC 접합부의 실물 성능실험을 통한 기계식이음 구조성능 평가)

  • Kim, Jae Young;Kim, Yong Nam;Seo, Min Jung;Kim, Beom Jin;Kim, Sung Jig;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.129-139
    • /
    • 2024
  • In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.

The analysis of tissue elasticity using computer-controlled ultrasonography in the affected upper limb of patients after breast cancer surgery

  • Chan-Hyuk Kwon;Min Woo Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.167-173
    • /
    • 2024
  • In this paper, we propse a quantitative research by investigating the subcutaneous tissue elasticity by using ultrasonography in lymphedema patients after breast cancer surgery. Lymphedema patients who took breast cancer operation were included. Thickness of subcutaneous tissue was assessed at two spots; 10cm below elbow (forearm) and 10cm above elbow (upper arm), not only in affected side but also in sound side. By using probe attached to real-time pressure sensor, stress-strain curves were obtained. We defined tissue elasticity as slope of that curve at range of 7.5~15% of strain to avoid toe region. By comparing the elasticity of normal side and that of affected side, lymphedema tissues were classified into 'softer' and 'harder' tissues. Overall 30 cases of lymphedema tissues and 30 cases of sound tissues were checked. The difference of the elasticity between normal and affected side ranged from -3.98 N/m2 to 1.40 N/m2. The lymphedema tissues were classified into 17 softer tissues and 13 harder tissues. No demographic and clinical values, including clinical stage of lymphedema, showed statistically meaningful differences between two groups. Evaluation of subcutaneous tissue elasticity with ultrasonography and real-time pressure sensor could be one of the useful tools for investigation of lymphedema tissue characteristics.

Impingement wastage experiment with SUS 316 in a printed circuit steam generator

  • Siwon Seo;Bowon Hwang;Sangji Kim;Jaeyoung Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.257-264
    • /
    • 2024
  • The sodium cooled fast reactor (SFR) is one of the Gen-IV reactors with the most operating experience accumulated. Although the technology level is the most mature among the Gen-IV reactors, there is still a safety problem that has not been solved, which is the sodium-water reaction. Since sodium and water are separated only by a heat transfer tube with a thickness of only a few mm, there is inherently a risk of a sodium-water reaction (SWR) accident in the SFR. In this study, it is attempted to quantitatively evaluate the resistance of SWR accidents by replacing the shell and tube steam generator with printed circuit steam generator (PCSG) as a method to mitigate the SWR accident. To do this, a CATS-S (Compact Accident Tolerance Steam Generator-SWR) facility was designed and built. And for the quantitative evaluation of accident resistance, a methodology for measuring the impingement wastage rate was established. As a result of this research, the impingement wastage rate caused by SWR generated in a PCSG was measured first time. It was confirmed that the impingement wastage phenomenon was suppressed in the PCSG, and the accident resistance was higher than that of the SWR through comparison with the experimental results performed in the existing shell and tube steam generator. In conclusion, a PCSG is more resistant to impingement wastage as a result of the SWR accident than existing shell and tube steam generators, and it is estimated that a PCSG can mitigate SWR accidents, an inherent problem of SFR.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

National Genetic Evaluation (System) of Hanwoo (Korean Native Cattle)

  • Park, B.;Choi, T.;Kim, S.;Oh, S.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.2
    • /
    • pp.151-156
    • /
    • 2013
  • Hanwoo (Also known as Korean native cattle; Bos taurus coreanae) have been used for transportation and farming for a long time in South Korea. It has been about 30 yrs since Hanwoo improvement began in earnest as beef cattle for meat yield. The purpose of this study was to determine the trend of improvement as well as to estimate genetic parameters of the traits being used for seedstock selection based on the data collected from the past. Hanwoo proven bulls in South Korea are currently selected through performance and progeny tests. National Hanwoo genetic evaluations are implemented with yearling weight (YW), carcass weight (CW), eye muscle area (EMA), backfat thickness (BF) and marbling score (MS). Yearling weights and MS are used for selecting young bulls, and EMA, BF, and MS are used for selecting proven bulls. One individual per testing room was used for performance tests, and five individuals per room for progeny tests. Individuals tested were not allowed to graze pasture, but there was enough space for them to move around in the testing room. Feeds including roughages and minerals were fed ad libitum, and concentrates were provided at the rate of about 1.8% of individual weight. Overall means of the traits were $352.8{\pm}38.56$ kg, $335.09{\pm}44.61$ kg, $77.85{\pm}8.838\;cm^2$, $8.6{\pm}3.7$ mm and $3.293{\pm}1.648$ for YW, CW, EMA, BF and MS. Heritabilities estimated in this study were 0.30, 0.30, 0.42, 0.50 and 0.63 in YW, CW, EMA, BF and MS, respectively, which are similar to results from previous research. Yearling weight was 315.54 kg in 1998, and had increased to 355.06 kg in 2011, resulting in about 40 kg of improvement over 13 yrs. YW and CW have improved remarkably over the past 15 yrs. Breeding values between 1996 and 2000 decreased or did not change much, but have moved in a desirable direction since 2001. These improvements correspond with the substantial increase in use of animal models since the late 1990s in Korea. Hanwoo testing programs have practically contributed to the improvement in aspects of quality and quantity. In sum, the current selection system is good enough to accommodate circumstances where fewer sires are used on many more cows. Although progeny tests take longer and cost more, they seem to be appropriate under the circumstances of the domestic market with its higher requirement for better meat quality. Consequently, accumulative data collection, genetic evaluation model development, revision of selection indices, as well as cooperation among farms, associations, National Agricultural Cooperative Federation, universities, research institutes, and government agencies must be applied to the Hanwoo selection program. All these efforts will assist the domestic market to secure a competitive position against imported beef under Free Trade Agreement trade system and will provide farmers with higher profits as well as the public with a higher quality of beef.

Performance Evaluation of Floor Vibration of Biaxial Hollow Slab Subjected to Walking Load (보행하중에 대한 2방향 중공슬래브의 진동성능 평가)

  • Kim, Min-Gyun;Park, Hyun-Jae;Lee, Dong-Guen;Hwang, Hyun-Sik;Kim, Hyun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.11-21
    • /
    • 2009
  • Considering that the weight of a biaxial hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a biaxial hollow slab is not significantly lower than that of a general solid slab, there has been a growing need for biaxial hollow slab systems, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a biaxial hollow slab system are quite different from the conventional floor systems. Therefore, in this study, the floor vibration of a biaxial hollow slab system subjected to walking load is investigated in comparison with a conventional floor slab system. For the efficiency of time history analysis, an equivalent plate slab model that can precisely represent the dynamic behavior of a biaxial hollow slab system is used. From the analytical results, it was determined that vibration of a biaxial hollow slab system subjected to walking load is evaluated as "office-level vibration," according to the classifications of the architectural institute of Japan and ANSI.

A Study on Characteristics Analysis of Multichannel Filter Module for Near-infrared Fluorescence Imaging (근적외선 형광 이미징 영상 구현을 위한 다채널 필터 모듈 특성분석 연구)

  • Choi, Jinsoo;Cho, Sang Uk;Kim, Doo-In;Lee, Hak-Guen;Choi, Hak Soo;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, development of multichannel filter module and characteristic evaluation for bio imaging were studied. The filter module was fabricated in order to realize near infrared fluorescence imaging of 700 nm and 800 nm wavelength ranges, and contrast imaging analysis for characteristic evaluation of the filter module was studied through signal to back ground ratio (SBR), controlled by parameters such as magnification, exposure, gain. Furthermore, phantoms, which are biomimetic tissue with equal optical properties of kidney and liver, were fabricated to study characteristics of both filter module depending on thickness and exposure amount of light source for bio imaging analysis. The fabricated filter module has more than 4 of SBR difference despite changes of magnification, exposure, gain, and in the case of the kidney phantom and the liver phantom, contrast imaging of more than 4 of SBR was confirmed on 50 mA, 60 mA exposure amount of light source respectively.