• Title/Summary/Keyword: thickness changes

Search Result 1,709, Processing Time 0.027 seconds

Electrochemical Behavior for a Reduction of Uranium Oxide in a $LiCl-Li_{2}O$ Molten Salt with an Integrated Cathode assembly

  • Park, Sung-Bin;Park, Byung-Heung;Seo, Chung-Seok;Jung, Ki-Jung;Park, Seong-Won
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.39-50
    • /
    • 2005
  • Electrolytic reduction of uranium oxide to uranium metal was studied in a $LiCl-Li_{2}O$ molten salt system. The reduction mechanism of the uranium oxide to a uranium metal has been studied by means of a cyclic voltammetry. Effects of the layer thickness of the uranium oxide and the thickness of the MgO on the overpotential of the cathode and the anode were investigated by means of a chronopotentiometry. From the cyclic voltamograms, the decomposition potentials of the metal oxides are the determining factors for the mechanism of the reduction of the uranium oxide in a $LiCl-3\;wt{\%} Li_{2}O$ molten salt and the two mechanisms of the electrolytic reduction were considered with regards to the applied cathode potential. In the chronopotentiograms, the exchange current and the transfer coefficient based on the Tafel behavior were obtained with regard to the layer thickness of the uranium oxide which is loaded into the porous MgO membrane and the thickness of the porous MgO membrane. The maximum allowable currents for the changes of the layer thickness of the uranium oxide and the thickness of the MgO membrane were also obtained from the limiting potential which is the decomposition potential of LiCl.

  • PDF

The Effect of Sputtering Conditions on Magnetic Properties of CoCrMo/Cr Magnetic Thin Film (CoCrMo/Cr 자성박막의 제조조건이 자기적성질에 미치는 영향)

  • 박정용;남인탁;홍양기
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.4
    • /
    • pp.320-324
    • /
    • 1993
  • The effect of sputtering conditions on magnetic properties of CoCrMo/Cr magnetic thin film was investigated. Substrate temperature were controlled from R. T to $250^{\circ}C$. The thickness changes of Cr underlayer and CoCrMo magnetic layer were in the range of $1000-2500\AA$ and $300-800\AA$, respectively. Grain size was found to be decreased with increasing magnetic layer thickness(from $500\AA$ to $800\AA$). CoCrMo magnetic layer microstructure showed relatively small dependence on Cr underlayer thickness, substrate temperature. Coercivity increased with increasing Cr underlayer, magnetic layer thickness and substrate temperature. CoCrMo/Cr thin film showed a coercivity of 880 Oe in $700\AA$ magnetic layer thickness and $1000\AA$ Cr underalyer thickness.

  • PDF

Body Shape Variations Measurements with 3D Scanner for Wearing Foundation (3D Scanner를 이용한 foundation 착용시의 인체 변화 계측)

  • Park, Ji-Eun;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.9 no.6
    • /
    • pp.651-657
    • /
    • 2007
  • This study was carried out to analyse body configuration and to observe any space between skin and foundation. A special 3D scanner was used to analyze this foundation. Experimental foundations were brassiere, girdle, and all-in-one. Four subjects volunteered, each subject was scanned while wearing foundation and not wearing foundation. Body shape variations were analyzed with an Auto CAD and ScanWax program which analyzes cross section of the skin surface to look for any changes. Height was increased all parts of body, circumference was increased in breast and bust while wearing the foundation. The hip thickness was not increased with wearing the foundation. Therefore this foundation makes people have a different appearance due to unexpected body shape variations. The effects of this foundation should be classified by observing height, circumference, and thickness changes in the body.

Polypyrrole Film Studied by Three-Parameter Ellipsometry

  • 김동래;이덕환;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.8
    • /
    • pp.707-712
    • /
    • 1996
  • Growth and changes of electronically conducting polypyrrole (PPy) in the form of thin films polymerized on metal electrodes were investigated by electrochemical and in situ three-parameter ellipsometry methods at the wavelength of 632.8 nm. Although the optical equations produced multiple sets of solution, it was possible to determine a unique set of thickness and the optical constants of a film by auxiliary measurements and/or physical reasoning. The changes in the thickness and the optical properties of the polymers during polymerization and electrochemical oxidation/reduction was successfully followed by the three-parameter ellipsometric technique. The optical properties of the polymers continuously changed as the film grew. The imaginary part of the refractive index of polypyrrole seemed to be dominantly determined by the existence of an absorption band around the visible range.

Evaluation of changes in the maxillary alveolar bone after incisor intrusion

  • Atik, Ezgi;Gorucu-Coskuner, Hande;Akarsu-Guven, Bengisu;Taner, Tulin
    • The korean journal of orthodontics
    • /
    • v.48 no.6
    • /
    • pp.367-376
    • /
    • 2018
  • Objective: This study was performed to investigate the changes in alveolar bone after maxillary incisor intrusion and to determine the related factors in deep-bite patients. Methods: Fifty maxillary central incisors of 25 patients were evaluated retrospectively. The maxillary incisors in Group I (12 patients; mean age, $16.51{\pm}1.32years$) were intruded with a base-arch, while those in Group II (13 patients; mean age, $17.47{\pm}2.71years$) were intruded with miniscrews. Changes in the alveolar envelope were assessed using pre-intrusion and post-intrusion cone-beam computed tomography images. Labial, palatal, and total bone thicknesses were evaluated at the crestal (3 mm), midroot (6 mm), and apical (9 mm) levels. Buccal and palatal alveolar crestal height, buccal bone height, and the prevalence of dehiscence were evaluated. Two-way repeated measure ANOVA was used to determine the significance of the changes. Pearson's correlation coefficient analysis was performed to assess the relationship between dental and alveolar bone measurement changes. Results: Upper incisor inclination and intrusion changes were significantly greater in Group II than in Group I. With treatment, the alveolar bone thickness at the labial bone thickness (LBT, 3 and 6 mm) decreased significantly in Group II (p < 0.001) as compared to Group I. The LBT change at 3 mm was strongly and positively correlated with the amount of upper incisor intrusion (r = 0.539; p = 0.005). Conclusions: Change in the labial inclination and the amount of intrusion should be considered during upper incisor intrusion, as these factors increase the risk of alveolar bone loss.

A Study on Flare Skirt Pattern by Utilizing CAD System (어패럴 CAD시스템을 활용한 플레어 스커트 연구)

  • 류경옥;송미령
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.139-148
    • /
    • 1998
  • This study was performed to develop the flare skirt pattern in CAD system by each of the textile's test. 1 made 28 flare skirts(360$^{\circ}$, length of 60 cm, straight gram at front ST side seam, 28 kind of textiles) and found the changes of skirt length. And I measured thickness, weight, density, drapability and bending in these textiles. Therefore, It analyzed these data and found it regression.

  • PDF

A Study on Chemical Mechanical Polishing using Pattern Density based Modeling (패턴 밀도를 고려한 Chemical Mechanical Polishing에 관한 연구)

  • 이재경;문원하;황호정
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.221-224
    • /
    • 2002
  • Recently, simulation of Chemical Mechanical Polis hing is becoming more important because Process parameters on the material removal rate are complicated. And pattern-depent effects are a key concern in CMP processes. In this paper, we have been studied the changes of pattern density vs. oxide thickness with Stine's simulation model. We also have estimated the effective density using optimal window size with density mask, and have made a study of the change of oxide thickness as a function of polishing time.

  • PDF

Change of Muscle Thickness on Exercise Type of Core Stabilization in Aged Men (남성노인의 코어 안정화 운동 형태가 근 두께에 미치는 영향)

  • Lim, Chaegil
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • Purpose : The purpose of this study was to provide more effective interventions for elderly men with weak core muscles by measuring the thickness of the muscles according to the five core stabilization exercise and comparing the thickness differences in muscles in each posture. Methods : The study selected 29 elderly men aged 65 to 80 years old among outpatient patients at S Medical Center in B city, and measured the muscle thickness by exercise posture once. In order to find out the thickness of the external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) muscles were measured by using rehabilitative ultrasound imaging (RUSI) in five exercise conditions. Results : A significant change in the thickness of the EO muscles in each group was measured by the method of motion, followed by the abdominal crunches (1.67±0.15), the lower body rotations (1.54±0.07). As a result of measuring the thickness of the IO muscles of each group according to the exercise method, the bridge group (1.14±0.22) was the highest, followed by the abdominal drawing group (1.05±0.03). As a result of measuring the thickness of the TrA muscles of each group according to the exercise method, the abdominal crunches (0.98±1.00) were the highest, and the bridge group (0.57±0.05) were higher in order of magnitude. Conclusion : Consequently, the five core stabilization exercises all affect changes in abdominal thickness and are expected to continue to require training studies on muscle posture.

Comparison of Muscle Thickness and Changing Ratio for Cervical Flexor Muscles During the Craniocervical Flexion Test Between Subjects With and Without Forward Head Posture

  • Lee, Jae-hyun;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.180-186
    • /
    • 2022
  • Background: The craniocervical flexion test (CCFT) was developed for the activation and endurance of deep cervical flexors. However, the muscle thickness and muscle thickness changing ratio of the sternocleidomastoid (SCM) and deep cervical flexor (DCF) muscles in subjects with and without forward head posture (FHP) have not been reported. Objects: To determine the difference in thickness of the SCM and DCF muscles and the difference in the muscle thickness changing ratio between SCM, DCF, and DCF/SCM 20 mmHg and DCF/SCM 30 mmHg between subjects with and without FHP. Methods: Thirty subjects with and without FHP were enrolled. The muscle thickness of the SCM and DCF was measured when maintained at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg using a pressure biofeedback unit during the CCFT. Ultrasonography was used to capture images of SCM and DCF muscle thickness during the CCFT, which was calculated using the picture archiving and communication system (PACS). Results: We observed a significant difference within the pressure main effect between SCM and DCF at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg (p < 0.05). However, there was no significant difference in the muscle thickness and muscle thickness changing ratio for SCM and DCF during CCFT between subjects with and without FHP. Conclusion: There was no significant difference in the muscle thickness recruitment pattern during CCFT in posture changes between subjects with and without FHP.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.