• Title/Summary/Keyword: thick-layer soft rock

Search Result 5, Processing Time 0.021 seconds

Optimization study on roof break direction of gob-side entry retaining by roof break and filling in thick-layer soft rock layer

  • Yang, Dang-Wei;Ma, Zhan-Guo;Qi, Fu-Zhou;Gong, Peng;Liu, Dao-Ping;Zhao, Guo-Zhen;Zhang, Ray Ruichong
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.195-215
    • /
    • 2017
  • This paper proposes gob-side entry retaining by roof break and filling in thick-layer soft rock conditions based on the thick-layer soft rock roof strata migration law and the demand for non-pillar gob-side entry retaining projects. The functional expressions of main roof subsidence are derived for three break roof direction conditions: lateral deflection toward the roadway, lateral deflection toward the gob and vertically to the roof. These are derived according to the load-bearing boundary conditions of the main roadway roof stratum. It is concluded that the break roof angle is an important factor influencing the stability of gob-side entry retaining surrounding rock. This paper studies the stress distribution characteristics and plastic damage scope of gob-side entry retaining integrated coal seams, as well as the roof strata migration law and the supporting stability of caving structure filled on the break roof layer at the break roof angles of $-5^{\circ}$, $0^{\circ}$, $5^{\circ}$, $10^{\circ}$ and $15^{\circ}$ are studied. The simulation results of numerical analysis indicate that, the stress concentration and plastic damage scope to the sides of gob-side entry retaining integrated coal at the break roof angle of $5^{\circ}$ are reduced and shearing stress concentration of the caving filling body has been eliminated. The disturbance of coal mining to the roadway roof and loss of carrying capacity are mitigated. Field tests have been carried out on air-return roadway 5203 with the break roof angle of $5^{\circ}$. The monitoring indicates that the break roof filling section and compaction section are located at 0-45 m and 45-75 m behind the working face, respectively. The section from 75-100 m tends to be stable.

Seismic exploration for understanding the subsurface condition of the Ilwall-dong housing construction site in Pohang-city, Kyongbook (경북 포항시 일월동 택지개발지구의 지반상태 파악을 위한 탄성파탐사)

  • Seo, Man Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.45-56
    • /
    • 1999
  • Seismic refracrion and reflection surveys were conducted along an E-W trending track of 482 m long in Ilwall-dong, Pohang. End-on spread was employed as source-receiver configuration with 2 m for both geophone interval and offset. Seismic data were acquired using 24 channels at every shot fired every 2 m along the track. Refraction data were interpreted using equations for multi-horizontal layers. Reflection data were processed in the sequence of trace edit, gain control, CMP sorting, NMO correction, mute, common offset gathering, and filtering to produce a single fold seismic section. There are two layers in shallow subsurface of the study area. Upper layer has the P-wave velocities ranging from 267 to 566 m/s and is interpreted as a layer of unconsolidated sediments. Lower layer has P-wave velocities of 1096-3108 m/s and is interpreted as weathered rock to hard rock. Most of the lower layer classified as soft rock. Upper layer has lateral variations in both P-wave velocity and thickness. The upper layer in the eastern part of the seismic line is 3-5 m thick and has P-wave velocity of 400 m/s in average. The upper layer in the western part is 8-10 m thick and has P-wave velocity of 340 m/s in average. The eastern part is interpreted as unconsolidated beach sand, while the western part is interpreted as infilled soil to develop a construction site. Three fault systems of high angle are imaged in seismic reflection section. It is interpreted that the area between these fault systems are relatively safe. Large buildings should be located in the safe ground condition of no fault and footings should be designed to be in the basement rock of 3-10 m deep below the surface.

  • PDF

Seismic Behavior of a Bridge with Pile Bent Structures Subjected to Multi-Support Excitation (다지점 가진에 의한 단일형 현장타설말뚝 교량의 지진거동)

  • Sun, Chang-Ho;Ahn, Sung-Min;Kim, Ick-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.425-434
    • /
    • 2019
  • It is important to ensure the seismic safety of pile-bent bridges constructed in areas with thick soft ground consisting of various soil layers against seismic motion in these layers. In this study, several synthetic seismic waves that are compatible with the seismic design spectrum for rock sites were generated, and the ground acceleration history of each soil layer was obtained based on ground analyses. Using these acceleration histories, each soil layer was modeled using equivalent linear springs, and multi-support excitation analyses were performed using the input motion obtained at each soil layer. Due to the nonlinear behavior of the soft soil layers, the intensity of the input ground motion was not amplified, which resulted in the elastic behavior of the bridge. In addition, inputting the acceleration history obtained from a particular layer simultaneously into all the ground springs reduced the response. Therefore, the seismic performance of this type of bridge might be overestimated if multi-excitation analysis is not performed.

Reduction Factor of the Site Coefficient due to the Foundation Embedment in the Soft Soil Layer for the Seismic Analysis of a Building (건축물의 지진해석을 위한 연약지반에 묻힌 기초로 인한 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.1-15
    • /
    • 2010
  • In this study, the reduction factor of the code-defined site coefficient due to the embedment of a foundation was estimated for the seismic analysis of a building built on a soft soil site. This was done by utilizing the in-house finite element software P3DASS, which has the capability of pseudo 3D seismic analysis with nonlinear soil layers. A 30m thick soft soil site laid on the rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were considered to be embedded at 0, 10, 20 and 30m in the soil layer. Seismic analyses were performed with 7 bedrock earthquake records deconvoluted from the outcrop records of which the effective ground acceleration was scaled to 0.1g. The study results showed that the site coefficients are gradually reduced except in the case of a small foundation embedded deeply in the weak soil layer, and it was estimated that the deviation of the site coefficients due to the foundation size was not significant. The standard reduction factor due to the foundation embedment were calculated adding the standard deviation to the average of 5 reduction factors calculated for 5 different foundation radii. Standard reduction factors for the site amplification factor were proposed for the practical amplification and the codes of KBC, etc., in accordance with the average shear wave velocity of the site, and the site class.

Mapping of Underground Geological Boundaries overlain by Conductive Overburden: Application of TEM Soundings (TEM 탐사에 의한 간척지내 전도성 표층 하부 지질 구성 파악)

  • Hwang, Hak-Soo;Moon, Sang-Ho
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.213-219
    • /
    • 2011
  • Transient/time-domain electromagnetic (TEM) soundings were carried out on reclaimed land, since the TEM sounding has good resolution of a conductive and thin overburden. The reclamation material is marine clay dredged from the seafloor, which is currently undergoing consolidation in the upper part of the dredged layer. The conductivity of the marine-origin clay is generally more than 0.3 S/m. The aim of the TEM sounding was to determine the depths of weathered and soft rocks overlain by thick and conductive overburden. The TEM responses were measured at delay times of 0.050-20.575 ms with a $30{\times}30$ m coincident loop array. Data from the TEM inversion and core logging indicate that the resistivities of the conductive overburden are less than 2 ${\Omega}$-m, while those of the weathered and soft rocks are 10-20 and 70 ${\Omega}$-m, respectively. The depth to weathered rock is 26-58 m and the depth to soft rock is 46-75 m.