• 제목/요약/키워드: thermotherapy device

검색결과 7건 처리시간 0.044초

한방의료기관의 온열 치료 기기 활용 현황 및 개발 수요에 대한 조사 연구 (A Survey on the Utilization and Demand of Thermotherapy Devices in Korean Medical Institutions)

  • 인소영;임수란;박지연;박정환;김송이
    • Korean Journal of Acupuncture
    • /
    • 제40권4호
    • /
    • pp.194-205
    • /
    • 2023
  • Objectives : This study investigated the current utilization status of thermotherapy devices in Korean medicine (KM) institutions and identified areas for improvement and further development, as perceived by KM doctors (KMDs). Methods : An online survey was conducted, targeting KMDs primarily engaged in clinical patient care. The questionnaire included items about respondents' clinical practices, the extent of thermotherapy device usage, their opinions on these devices, and perceived improvement needs. The collected data underwent quantitative analysis. Results : From the 1,025 respondents, data from 862 respondents who provided complete responses were analyzed. On average, respondents utilized thermotherapy treatments for 80% of their patients. Infrared (IR) phototherapy unit, electrical moxibustion apparatus, and heater-based thermotherapy devices were predominantly owned by respondents, with IR being the most frequently used. The average satisfaction score for current thermotherapy devices was 79. A significant concern raised was the necessity for improved health insurance coverage and efficacy evaluation. Conclusions : This research has confirmed that the extensive use of thermotherapy devices by KMDs in treating primarily musculoskeletal and gastrointestinal ailments - common conditions among patients in KM institutions. The main areas identified for improvement encompass safety, cost-effectiveness, and device efficacy. Future enhancements in thermotherapy devices should address these crucial aspects.

드롭랜딩 시 국소부위 온열처치와 동적 준비운동이 하지의 운동역학적 변인에 미치는 영향 (Thermotherapy and Dynamic Warm-up on the Kinetic Parameters during Drop-landing)

  • Kim, Sungmin;Song, Jooho;Han, Sanghyuk;Moon, Jeheon
    • 한국운동역학회지
    • /
    • 제31권4호
    • /
    • pp.297-307
    • /
    • 2021
  • Objective: The aim of this study was to analyze kinetic variables between thermotherapy and dynamic warm-up during drop-landing. Method: Twenty male healthy subjects (Age: 21.85 ± 1.90 years, Height: 1.81 ± 0.06 cm, Weight: 68.5 ± 7.06 kg) underwent three treatments applied on the thermotherapy of femoral muscles and a dynamic warm-up. The thermotherapy was performed for 15 minutes while sitting in a chair using an electric heating pad equipped with a temperature control device. Dynamic warm-up performed 14 exercise, a non-treatment was sitting in a chair for 15 minutes. Core temperature measurements of all subjects were performed before landing at a height of 50 cm. During drop-landing, core temperature, joint angle, moment, work of the sagittal plane was collected and analyzed. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was Bonferroni. Results: Results indicated that Thermotherapy was increased temperature than other treatments (p = .000). During drop-landing, hip joint of dynamic warm-up was slower for angular velocity (p < .005), and left ankle joint was fastest than other treatments (p = .004). Maximum joint moment of dynamic warm-up was smaller for three joints (hip extension: p = .000; knee flexion/extension: p = .001/.000; ankle plantarflexion: p = .000). Negative work of dynamic warm-up was smaller than other treatments (p = .000). Conclusion: In conclusion, the thermotherapy in the local area doesn't affect the eccentric contraction of the thigh. The dynamic warm-up treatment minimized the joint moment and negative work of the lower joint during an eccentric contraction, it was confirmed that more active movement was performed than other treatment methods.

생리통 완화를 위한 저주파 치료기(TENS) 내장 스마트 의복 개발 연구 (R & D of Smartwear Built-In TENS Device for Relief of Dysmenorrhea)

  • 이원준;엄소희
    • 복식문화연구
    • /
    • 제17권2호
    • /
    • pp.320-329
    • /
    • 2009
  • This research attempts to develop a method to relieve dysmenorrhea, which is an obstacle to many women's social activities, by designing a smartwear with built-in thermotherapy and TENS device. TENS therapy has the advantages of being controlled by patients and not depending on the use of drugs. The TENS device is designed as a stomach band so as to be unnoticeable to others when outer clothes are worn; the size was minimized and attached to underwear to facilitate use everywhere at any time. A current problem is the limitation of minimizing, but as battery technology is further developed, we can anticipate much smaller devices. The development of aforementioned smartwear function will increase women's choices in occupations and general improvement in quality of life.

  • PDF

Development of the Electronic Moxibustion Device for Realizing the Heating Effect of the Moxa Cautery

  • Kim, Tae-Gon;Lee, Yu-Mi;Park, Yong-Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.28-31
    • /
    • 2014
  • This study aims to develop an electronic moxibustion device for the quantification of moxibustion, which progresses a critical role in traditional oriental medicine as well as to assess the characteristics of heating. The assessment revealed that the proposed electronic moxibustion treatment device can reduce the time required for reaching the desired heat level and continue to provide heat consistently. Moreover, heat transmitted to the treated area was found to correspond to a heating pattern of the proposed electronic moxibustion device. It proved both quantitative control and safe treatment for the proposed electronic moxibustion device.

Effect of Wearing a Thermal Compression Sleeve on Isokinetic Strength and Muscle Activity of Wrist Flexors and Extensors

  • Kim, Ki Hong;Jeong, Hwan Jong;Hong, Chan Jeong;Kim, Hyun Sung;Kim, Byung Kwan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.183-191
    • /
    • 2022
  • The purpose of this study, the wearing conditions of functional pressure clothing applied with the thermotherapy device were determined by three types (NW, CW, TCW) and the difference in isokinetic strength, muscle activity around the forearm was investigated and the effects of products mixed with thermotherapy and pressure treatment were verified. Ten men in their 20s were selected as subjects, and all subjects were randomly assigned three wearing conditions, and wrist flexion/extension exercise was performed at 30° and 90° angular velocity in isokinetic equipment. Peak torque, average power, and EMG were measured during exercise in all conditions. For peak torque, CW was significantly highest at velocity of 30°/sec flexion. Average power showed no significant difference by condition. In the angular velocity of 90°/sec, flexion was significantly higher in CW and TCW than in NW. As a result, wearing clothes with pressure effect and heat effect can show high efficiency in high muscle strength development and fast contraction activity during low speed exercise, and it is thought that it can show improvement of exercise ability through efficient recruitment of motor unit.

조직모델에서 냉.온치료기의 열전달 특성 비교 연구 (A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities)

  • 김유종;신경민;김은정;김경호;김갑성;이승덕
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.125-138
    • /
    • 2013
  • Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.

기외 열처리와 경정접목을 이용한 사과 폿트묘에서의 바이러스 제거 (Combining ex vitro thermotherapy with shoot-tip grafting for elimination of virus from potted apple plants)

  • 천재안;권지영;이선기
    • Journal of Plant Biotechnology
    • /
    • 제49권3호
    • /
    • pp.222-229
    • /
    • 2022
  • 사과는 국내 과수산업에서 가장 많이 재배되고 있는 과종이다. 하지만 apple mosaic virus (ApMV), apple stem grooving capillovirus (ASGV), apple stem pitting virus (ASPV), apple chlorotic leaf spot virus (ACLSV), apple scar skin viroid (ASSVd)와 같은 바이러스 및 바이로이드에 감염되면 과실의 수확량 감소 및 품질 저하를 야기시킨다. 본 연구에서는 국내 사과 농가에서 가장 많이 감염되어 있는 ASGV 바이러스를 제거하기 위한 효율적인 무병화 시스템을 확립하고자 하였다. ASGV에 감염된 폿트묘를 36℃, 38℃, 40℃가 유지되는 항온·항습장치에서 4주간 열처리를 수행하였으며, 신초 생장율과 바이러스 제거율을 조사하였다. 신초 생장률은 36℃ 처리구에서 가장 높았으며 신초의 중간부와 상단부는 바이러스가 제거되었으나 하단부는 바이러스가 제거되지 않았다. 38℃, 40℃ 처리구는 신초의 모든 구간에서 바이러스가 제거되지 않았으며, 40℃ 처리구는 신초의 생장 없이 열처리 3주 후 고사되었다. 36℃ 온도에서 열처리된 폿트묘의 경정을 절취하여 기외에서 접목하였으며 94%의 생존율과 20%의 바이러스 제거율을 보였다. 따라서 열처리 및 경정접목을 통해 무병묘 생산이 가능할 것으로 판단되었다.