• 제목/요약/키워드: thermometer

검색결과 356건 처리시간 0.029초

정규기상관측자료를 이용한 주간의 현열 플럭스 추정 (Estimation of Daytime Sensible Heat Flux using Routine Meteorological Data)

  • 이종범;김용국;박철용
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.109-114
    • /
    • 2000
  • The purpose of the present study is to develope the estimation scheme for sensible heat flux by semi-empirical approach using routine meteorological data such as solar radiation and air temperature. To compare observed sensible heat flux with estimated sensible heat flux, the sensible heat fluxes were measured by three dimensional sonic anemometer-thermometer. The field observation was performed during 1 year from December 1, 1995 to November 30, 1996 on a rice paddy field in Chunchon basin. The heat fluxes were measured at a heights of 5m and mean meteorological variables were obtained at two levels, 2.5m(or 1.5m) and 10m. Since condition of rice paddy field such as, wetness of the field, roughness length, vary widely, we devided annual data to 5 periods. Comparing with two sensible heat fluxes, the results showed that the correlation coefficients were more than 0.86. Thus, we can conclude that the estimation method of sensible heat fluxes using routine meteorological data is practical and reliable enough.

  • PDF

Programmable Digital On-Chip Terminator

  • Kim, Su-Chul;Kim, Nam-Seog;Kim, Tae-Hyung;Cho, Uk-Rae;Byun, Hyun-Guen;Kim, Suki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1571-1574
    • /
    • 2002
  • This paper describes a circuit and its operations of a programmable digital on-chip terminator designed with CMOS circuits which are used in high speed I/O interface. The on-chip terminator matches external reference resistor with the accuracy of ${\pm}$ 4.1% over process, voltage and temperature variation. The digital impedance codes are generated in programmable impedance controller (PIC), and the codes are sent to terminator transistor arrays at input pads serially to reduce the number of signal lines. The transistor array is thermometer-coded to reduce impedance glitches during code update and it is segmented to two different blocks of thermometer-coded transistor arrays to reduce the number of transistors. The terminator impedance is periodically updated during hold time to minimize inter-symbol interferences.

  • PDF

IGBT의 열 특성 및 히트싱크 모델링 (Thermal Characteristics and Heatsink Modeling. for IGBT)

  • 류세환;배경국;신호철;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.172-173
    • /
    • 2007
  • As the power density and switching frequency increase, thermal analysis of power electronics system becomes imperative. The thermal analysis provides valuable information on the semiconductor rating, long-term reliability. In this paper, thermal distribution of the Non Punchthrough(NPT) Insulated Gate Bipolar Transistor has been studied. For analysis of thermal distribution, we obtained experimental and simulation results by using finite element simulator, Ansys and by using photographic infrared thermometer, we compared experimental date with simulation result. and got good agreement. Also this paper provided thermal distribution of IGBT connected to heat sinks. and this results will be good information to design optimal heat sink for IGBT.

  • PDF

바이메탈식 온도센서를 적용한 건조설비에서의 화재 위험성 연구 (Study of the Fire Risk Caused by the Use of a Bimetal type Thermometer in the Drying Equipment)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.73-78
    • /
    • 2017
  • 본 논문에서는 바이메탈식 온도센서를 적용한 건조설비에서의 화재 위험성에 대하여 연구하였다. 건조설비는 산업현장 등에서 광범위하게 사용되고 있으며, 건조 대상물이 가열될 때 발생하는 가연성 가스 및 증기에 의한 폭발 및 화재 등이 일어나기 용이하기 때문에 구조와 사용방법 등에 대한 규제가 엄격하게 이루어지고 있지만 부적합한 온도센서를 활용한 건조로 등의 내부온도 측정시 정확한 온도 측정이 이루어지지 못하는 경우에는 그만큼 화재 위험성이 증가하게 된다. 따라서 본 논문에서는 건조설비에 광범위하게 사용되고 있는 바이메탈식 온도센서의 구조를 분석하고, 측정 대상물의 성상에 따른 온도 측정 실험을 수행하였다. 측정 대상물에 따른 온도 측정 결과, 기체 및 고체에 대한 온도 측정에 있어서는 실제 온도에 비해 낮은 온도로 측정되었으며, 액체 대상물의 경우에는 비교적 정확한 온도 측정이 가능하였다. 이러한 실험 결과로부터 바이메탈식 온도센서는 기체 및 고체의 온도 측정에는 부적합하며, 액체의 온도 측정에 보다 적합한 특성을 나타내었다.

Development of Two-color Radiation Thermometer for Harsh Environments

  • Mohammed, Mohammed Ali Alshaikh;Kim, Ki-Seong
    • 한국분무공학회지
    • /
    • 제21권4호
    • /
    • pp.184-194
    • /
    • 2016
  • Many industrial processes require reliable temperature measurements in harsh environments with high temperature, dust, humidity, and pressure. However, commercially-available conventional temperature measurement devices are not suitable for use in such conditions. This study thus proposes a reliable, durable two-color radiation thermometer (RT) for harsh environments that was developed by selecting the appropriate components, designing a suitable mechanical structure, and compensating environmental factors such as absorption by particles and gases. The two-color RT has a simple, compactly-designed probe with a well-structured data acquisition system combined with efficient LabVIEW-based code. As a result, the RT can measure the temperature in real time, ranging from 300 to $900^{\circ}C$ in extremely harsh environments, such as that above the burden zone of a blast furnace. The error in the temperature measurements taken with the proposed two-color RT compared to that obtained using K-type thermocouple readouts was within 6.1 to $1.4^{\circ}C$ at a temperature range from 200 to $700^{\circ}C$. The effects of absorption by gases including $CO_2$, CO and $H_2O$ and the scattering by fine particles were calculated to find the transmittance of the two wavelength bands of operation through the path between the measured burden surface and the two-color probe. This method is applied to determine the transmittance of the short and long wavelength bands to be 0.31 and 0.51, respectively. Accordingly, the signals that were measured were corrected, and the true burden surface temperature was calculated. The proposed two-color RT and the correction method can be applied to measure temperatures in harsh environments where light-absorbing gases and scattering particles exist and optical components can be contaminated.

정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구 (An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions)

  • 윤홍석;문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.34-41
    • /
    • 2015
  • 정상 및 비정상상태의 화재조건에서 설치가 용이하고 저가형인 판형 열유속계(PT)의 적용성에 대한 실험적 연구가 수행되었다. 열원으로서 적외선 복사 히터와 C3H8이 적용된 정사각형 버너가 사용되었다. PT의 상대적 측정 정확도는 Gardon-type 열유속 미터를 이용한 측정결과와의 비교를 통해 평가되었다. 정상 및 비정상상태의 화재조건에서 PT의 최적 크기 및 두께는 측정 정확도와 실용적 관점에서 각각 100 mm와 0.6 mm로 확인되었다. 이 결과들은 PT의 크기 및 두께의 변화에 따른 전도 열손실과 열관성에 의해 설명되었다. 또한 Slow보다 빠른 화재 성장속도의 조건에서 PT를 이용한 열유속 측정에는 상당한 주의가 요구됨을 확인하였다.

도심 녹음수의 체감온도지수(WBGT) 조절효과 (The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index))

  • 주민진;이춘석;류남형
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)

℃ 이하 적외선 복사온도계 비교 교정장치 구축 (Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃)

  • 유용심;김봉학
    • 한국광학회지
    • /
    • 제29권2호
    • /
    • pp.70-76
    • /
    • 2018
  • $0^{\circ}C$ 이하 적외선 복사온도계의 복사온도눈금 교정을 위해 기준 복사온도계 TRT2 (Transfer Radiation Thermometer 2, HEITRONICS)와 온도가변 흑체 ME30 (Model: ME30, HEITRONICS)을 사용하여 비교 교정장치를 구축하였다. 3개의 고정점(Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), Sn ($231.928^{\circ}C$))과 플랑크형 사쿠마-하토리식을 사용하고, $-50^{\circ}C$에서 TRT2의 내외삽 오차를 불확도에 포함시켜 TRT2의 복사온도 눈금을 교정하였다. ME30 흑체 개구에 공압으로 동작되는 뚜껑을 설치한 후 30초 동안만 뚜껑을 열고 복사온도를 측정함으로써 ME30 내에서 생기는 성에를 방지할 수 있었으며 비교 교정에 소요되는 시간도 반으로 줄일 수 있었다. $0{\sim}232^{\circ}C$ 영역 밖으로 벗어날수록 비교 교정장치의 불확도는 증가하며 $-20^{\circ}C$에서 확장 불확도는 0.26 K였다.

초등학생의 실험 기구 조작 능력에 대한 실태 조사 (A Fact-finding Research Exercise into the Handling Abilities of Experimental Apparatus by Elementary School Students)

  • 박재원;윤상미;원정애;백성혜
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제26권2호
    • /
    • pp.161-170
    • /
    • 2007
  • This study aims at helping us improve the methods used to teach elementary school students how to handle experimental apparatus by examining their manual skills and their understanding of the alcohol lamp, spuit and thermometer. To evaluate their ability to handle each experimental apparatus, a practical skills test and knowledge evaluation sheets were developed. The evaluation was carried out with 270 students from 2 classes each in the 3rd, 4th, 5th and 6th grade of D Elementary School located in Daejeon City. For their handling ability of the alcohol lamp, the results for the practical skills test showed that the students had a very low ability in placing objects in the center of the apparatus for safe use and also in adjusting the height of the trivet to place objects so that they contact the outer flames correctly. For the spuit, the pass rate of the skills test was generally low in regards to how students should grasp a spuit and the timing and method of depressing the rubber part before dipping it into liquid. For the thermometer, on the other hand, the pass rate was relatively high in every respect. The knowledge evaluation results for the use of experimental apparatus showed a very high rate of correct answers for alcohol lamps and thermometers. The test results for spoils also produced a relatively high rate of correct answers, with the exception of the test item regarding the way that students should grasp them.

  • PDF