• Title/Summary/Keyword: thermographic

Search Result 205, Processing Time 0.025 seconds

Effects of Qigong therapy on the thermal changes of upper, middle, lower $Danj{\breve{o}}n$(Ex-HN3, CV17, CV4) examined by Digital Infrared Thermographic Imaging(DITI) (기공체조(氣功體操)가 DITI로 촬영한 상(上), 중(中), 하단전(下丹田)의 체표온도(體表溫度)에 미치는 영향(影響))

  • Nam, Sang-Soo;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 2002
  • Objectives : It is the object of Qigong therapy to promote the circulation of Qi and blood, and to relieve mentality by way of warming lower Danjon. In this study, to prove that Qigong therapy could actually subside heat on upper or middle Danjon and warm the temperature on lower Danjon, we observed the thermal changes of upper, middle, lower Danjon before and after Qigong therapy and compared them. Methods : We selected 16 patients, treated Qigong therapy and examined by D.I.T.I.(Digital Infrared Thermographic Imaging) before and after Qigong therapy, among patients who visited. Qigong clinic, Kangnam Korean hospital, Kyunghee University(Daechi-2dong, Kangnam-Gu) from april to october, 1999. We watched the difference of temperature among upper, middle, lower Danjon before and after Qigong therapy, and used student T-test(paired type, 2 tail) for proving effects of Qigong therapy statistically. Conclusions 1. The difference of temperature$({\Delta}T)$ between upper(Ex-HN3) and lower Danjon(CV4) significantly decreased about $0.55^{\circ}C$ after Qigong therapy(p<0.01). 2. The difference of temperature${\Delta}T$ between middle(CV17) and lower Danjon(CV4) significantly decreased about $0.39^{\circ}C$ after Qigong therapy(p<0.05). 3. The difference of temperature${\Delta}T$ between upper(Ex-HN3) and middle Danjon(CV17) decreased about $0.25^{\circ}C$ after Qigong therapy, but it was not statistically significant.

  • PDF

Thermographic Inspection of Fatigue Crack by Using Contact Thermal Resistance (접촉 열저항 효과를 이용한 피로균열의 적외선검사)

  • Yang, Seungyong;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.187-192
    • /
    • 2013
  • Fatigue crack was detected from a temperature change around surface crack using the thermographic technique. Thermal gradient across the crack decreased very much due to thermal resistance of contact surface in the crack. Heat diffusion flow passing through the discontinuity was visualized in temperature by infrared camera to find and locate the crack. A fatigue crack specimen(SM-45C), which was prepared according to KS specification and notched in its center to initiate fatigue crack from the notch tip, was heated by halogen lamp at the end of one side to generate a heat diffusion flow in lateral direction. A abrupt jump in temperature across the fatigue crack was observed in thermographic image, by which the crack could be located and sized from temperature distribution.

A Case Report on the Effects of Gamiguibi-tang Combined with Sweet Bee Venom to Improve Raynaud's Disease (봉약침 치료와 병행한 가미귀비탕으로 호전된 레이노병 환자 치험 1례)

  • Lee, Myeong-hwa;Son, byeon-woo;Kim, Kyoung-min;Kim, Young-kyun
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.5
    • /
    • pp.698-708
    • /
    • 2017
  • Objectives: The aim of this study was to report the clinical effects of a combination of Gamiguibi-tang and sweet bee venom on a patient with Raynaud's disease. Methods: The patient with Raynaud's disease was treated with Gamiguibi-tang three times a day for 43 days and with sweet bee venom daily. The effects on Raynaud's disease were measured on both hands using a cold stress test and an infrared thermometer and by digital infrared thermographic imaging and a NRS (Numeric Rating Scale). We conducted the cold stress test at 6-8 day intervals from 2016.04.27 to 2016.06.08. Results: After treatment, the symptoms of pain were decreased in both hands and digital infrared thermographic imaging (DITI) confirmed a rise in the temperature of the fingers. The fingertip temperature increased from 29.6 to 30.4 degrees and the cooling/rewarming ratio (CRR) increased steadily. No adverse events were found at discharge. Conclusions: Gamiguibi-tang combined sweet bee venom may improve symptoms in patients with Raynaud's disease.

A Case report of Idiopathic Scoliosis Patient : Comparison of X-ray and Digital Infrared Thermographic Imaging (특발성 척추측만증 환자의 X-ray와 적외선 체열촬영의 비교 1례)

  • Jo, Jun-Young;Kim, Jin-Woo;Park, Kyoung-Sun;Lee, Jin-Moo
    • Journal of Oriental Medical Thermology
    • /
    • v.9 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • Purpose : The purpose of this study is to report the comparison of X-ray and Digital Infrared Thermographic Imaging (DITI) of a patient with idiopathic scoliosis. Method: The patient in this case was a 25-year-old female. Her chief complaint was a pain in lumbar, scapular and shoulder regions. We examined her with DITI and X-ray. And then We compared DITI and X-ray. Results: Cobb's angle of thoracic spine was $24.78^{\circ}$ as a primary curve. Cobb's angle of thoracolumbar spine was $17.63^{\circ}$. Temperature on convex side of the thoracic spine was $0.3^{\circ}C$ higher than the other side. Temperature on convex side of cervical spine was $1.4^{\circ}C$ higher than the other side. There was no correlation curvature degree with temperature difference. Conclusion : There was a tendency that the temperature on convex side of the spine is higher than the other side of the spine. DITI is a useful assessment tool when it is used with X-ray as a diagnostic tool of idiopathic scoliosis. Further studies are needed.

  • PDF

A Basic Study to Reveal the Relationships between Solar Thermal Radiation and Thermographic Images (태양 복사와 열화상이미지의 관계에 대한 기초 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2020
  • Among the factors that must be taken into account when using thermal imaging cameras that are expanding their application to various fields, a basic study was conducted focusing on temperature on the effect of solar radiation on the photographed thermal image. Through all experiments, in order to use an image taken with a thermal imaging camera for an object installed or located outdoors, a separate temperature correction according to the size of solar radiation or a separate device to block the effect of solar radiation must be additionally installed. Since the temperature of the same object may vary in the thermal image taken indoors or outdoors, it is necessary to calibrate it through comparison with other temperatures as a reference point. In the case of measuring the temperature of a glossy surface such as metal indoors with a thermal imaging camera, it was confirmed that an environment that can remove the light reflection effect by the glossy surface must be constructed and photographed.

Case Report of Raynaud's Disease Treated with Prescription of Modified Woogyu-yeum (우귀음가미방(右歸飮加味方) 투여로 호전된 레이노 병 환자 1례)

  • Ha, Ye-Jin;Cho, Mun-Young;Jang, Won-Seok;Eun, Seon-Hye;Shin, Yong-Jeen;Shin, Sun-Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.5
    • /
    • pp.908-913
    • /
    • 2011
  • Major symptoms of Raynaud's Disease are pain, edema, cyanosis, and redness of hands, feet, nose, and etc. The purpose of this report is to show the curative effect of herbal medicine for Raynaud's Disease. We provided Prescription of Modified Woogyu-yeum(Yougui-yinjiaweifang ) to patient who was diagnosed with Raynaud's Disease three times a day for 22 days. We observed changes of symptoms through Digital Infrared Thermographic Imaging, taking photos of both hands, and collecting the survey answered by the patient. Modified Woogyu-yeum reduced pain, edema, and redness of both hands. The frequency of cyanosis decreased after the treatment. Digital Infrared Thermographic Imaging proved a rise in temperature of fingertips after the treatment. In conclusion, Modified Woogyu-yeum showed the possibility of effect on Raynaud's Disease.

Changes of Infrared Thermographic Findings in Bilateral Bell's Palsy Treated with Stellate Ganglion Block -A case report- (양측성 안면마비에서 적외선 체열 영상 촬영으로 평가한 성상신경절 차단의 치료 효과 -증례 보고-)

  • Lee, Youn-Woo;Jeong, Joo-Young;Kim, Hee-Jung;Shin, Yang-Sik
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.93-97
    • /
    • 2001
  • Facial nerve palsy is not a serious disease, but it can be both upsetting and disabling for patients. More than half of the lesions of facial nerve palsy fall into the category termed Bell's palsy. It is very rare to find a representative case of bilateral Bell's palsy. Here we report the changes of infrared thermographic findings in bilateral Bell's palsy treated with a stellate ganglion block (SGB). A 45-year-old female patient who had a right facial palsy which developed 2 weeks before. Steroid administration and acupuncture was not effective and so she was referred to pain clinic. The right facial palsy was cured after 19th right SGB. Twenty eight days after the onset of the right facial palsy, left facial palsy also developed and cured completely with a left SGB. Serial infrared thermograms were performed. The hypothermias on the affected side improved symmetrically by the end of the treatment.

  • PDF

The Nondestructive Reliability Evaluation which it Applies Ultrasound Thermography about Cutting Crack of Piston Skirt (초음파 서모그래피를 적용한 피스톤 스커트 절단균열에 대한 비파괴 신뢰성 평가)

  • Yang, Yong-Ha;Ma, Sang-Dong;Kim, Jea-Yeol
    • Tribology and Lubricants
    • /
    • v.26 no.6
    • /
    • pp.336-340
    • /
    • 2010
  • Ultrasound thermography detects defects by radiating 20 ~ 30 kHz ultrasound waves to the samples and capturing the heat generated from the defects with the use of an infrared thermographic camera. This technology is being spotlighted as a next-generation NDE for the automobile and aerospace industries because it can test large areas and can detect defects such as cracks and exfoliations in real time. The heating mechanism of the ultrasound vibration has not been accurately determined, but the thermomechanical coupling effect and the surface or internal friction are estimated to be the main causes. When this heat is captured by an infrared thermographic camera, the defects inside or on the surface of objects can be quickly detected. Although this technology can construct a testing device relatively simply and can detect defects within a short time, there are no reliable data about the factors related to its detection ability. In this study, the ultrasound thermography technique was used to manufacture gasoline and diesel engine piston specimens, and nondestructive reliability tests to verify the applicability and validity of the ultrasound thermography technique.

Standardization of Temperature Measurement System for Stable and Reliable Infrared Thermographical Image (열화상 이미지의 신뢰성 확보를 위한 온도입력시스템의 표준화)

  • Yoon, Se-Hyun;Chung, Lan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.681-687
    • /
    • 2008
  • This study presents a technique to quantitatively measure the corrosion level of a reinforcing bar using infrared thermography system. We found out electric heating method having an important effect on thermal data in previous study. This study purposed an efficient way for grip standardization to reduce constriction resistance problem, and providing reliable thermal data using infrared thermographic method. Using vise type earth clamp, the surface resistance of rebar was smaller than that of traditional plier type earth clamp through temperature-distribution relationship. Also this study contains experiments with toque wrench to improve heating contact problem.

BIM and Thermographic Sensing: Reflecting the As-is Building Condition in Energy Analysis

  • Ham, Youngjib;Golparvar-Fard, Mani
    • Journal of Construction Engineering and Project Management
    • /
    • v.5 no.4
    • /
    • pp.16-22
    • /
    • 2015
  • This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. Several case studies were conducted to experimentally evaluate their impact on BIM-based energy analysis to calculate energy load. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.