• 제목/요약/키워드: thermocycling

검색결과 229건 처리시간 0.204초

상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향 (EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS)

  • 이용우;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

  • Lee, Jung-Jin;Kang, Cheol-Kyun;Oh, Ju-Won;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE. This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS. Sixty specimens were cut in $15{\times}2.75mm$ discs using zirconia. After air blasting of $50{\mu}m$ alumina, samples were prepared by tribochemical silica coating with $Rocatec^{TM}$ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+$Calibra^{(R)}$, (2) Monobond S+$Multilink^{(R)}$ N and (3) ESPN sil+$RelyX^{TM}$ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS. In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION. In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.

치과용 금합금에 대한 금속 프라이머 처리와 열순환 처리가 교정용 브라켓의 전단결합강도에 미치는 영향 (Effect of metal primer and thermocycling on shear bonding strength between the orthodontic bracket and gold alloy)

  • 이영기;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.320-329
    • /
    • 2009
  • 치과용 금합금에 교정용 브라켓 접착 시 금속 프라이머와 열순환 처리가 전단결합강도에 미치는 영향을 알아보기 위하여 80개의 치과용 금합금 시편을 샌드블라스팅만 처리한 군과 3종류의 금속 프라이머(Alloy Primer, Metaltite, V-Primer)처리를 시행한 군으로 분류하고, 이를 열순환 처리 시행 여부에 따라 모두 8개 군으로 분류하였다. 만능물성 시험기를 사용하여 브라켓의 전단결합강도를 측정하고, modified ARI (Adhesive Remnant Index) scores를 통해 브라켓 접착면의 파절 양상을 평가하였다. 열순환 처리 미시행 시에는 금속 프라이머의 적용 시 샌드블라스팅만 단독으로 처리한 경우에 비하여 통계적으로 유의성 있는 전단결합강도의 증가가 있었다 (p < 0.05). 열순환 처리를 시행한 군에는 금속 프라이머의 처리에 의한 전단결합강도의 변화는 유의한 차이가 없었다 (p > 0.05). 금속 프라이머를 적용한 경우 열순환 처리 미시행 시에는 파절 양상이 브라켓과 접착제 계면에서의 파절 발생 빈도가 높았으나, 열순환 처리 시행 시에는 각 군 간 파절 양상에 유의한 차이가 없었다. 이상의 결과로 금속 프라이머의 적용이 치과용 금합금에 대한 교정용 브라켓 접착 시 초기 접착 강도에서는 유의성 있는 결합력의 증가를 보이나, 열순환 처리 시행 후에는 결합 강도에서는 유의한 차이가 없는 것으로 나타나 금속 프라이머에 의한 결합력 증가가 감소하는 것으로 생각한다.

치아표면 처리방법과 thernocycling이 콤포짓트 레진 코어의 미세누출에 미치는 영향 (THE EFFECTS OF SURFACE TREATMENT AND THERMOCYCLING ON THE MICROLEAKAGE OF COMPOSITE RESIN CORES)

  • 임용철;진태호
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.255-263
    • /
    • 2000
  • The purpose of this study was to compare the microleakage of the composite resin cores according to surface treatment, dentin bonding agents, and thermocycling. For this study, 120 extracted premolar teeth were used. Flat occlusal surfaces were prepared with diamond disk, and treated with air-abrasion, acid-etching, combination. The composite resin core was built with Z-100 after application of Scotchbond Multi-Purpose and All-Bond 2. Prepared specimens were thermocycled for 2,000 cycles. Specimens were immersed in 1% methylene blue solution for 24hours at $37^{\circ}C$. The microleakage was measured with a inverted metallurgical microscope(BHS313, Olympus, Japan). The following conclusions were drawn from this study: 1. The microleakages in the groups treated with air-abrasion and with acid etching were greater than that of the groups treated with combination method before thermocycling(p<0.05), the microleakages of the groups treated with air-abrasion were greater than that of the groups treated with acid-etching and combination method after thermocycling(p<0.05) 2. There were no significant difference between groups using Scotchbond Multi-Purpose and the groups using All-Bond 2. 3. Thermocycling didn't affect the change of microleakage in all cases.

  • PDF

영구 연성 의치상 이장재의 물리적 성질에 관한 연구 (THE STUDY ON THE PHYSICAL PROPERTY OF THE PERMANENT SOFT DENTURE LINERS)

  • 김연미;배정식
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.809-818
    • /
    • 1999
  • This study was performed to evaluate the tensile bond strength and modulus of elasticity of three permanent soft denture liners (Molloplast $B^{(R)}$, Ufi Gel $C^{(R)},\;Tokuyama^{(R)}$) before and after thermocycling. And their water sorption were also evaluated. Each soft denture liner was bonded to PMMA denture base resin blocks and the tensile bond strength and modulus of elasticity were measured by using universal testing machine. For the water sorption, weight measured after immersion of sea denture liners in $37{\pm}1^{\circ}C$ water bath for 4 weeks. The results were as follows : 1. Molloplast $B^{(R)}$ had the highest tensile bond strength, while Tokuyama had the lowest tensile bond strength. There was no significant difference between $Tokuyama^{(R)}$ and Molloplast $B^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in tensile strength of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 2. For the modulus of elasticity, there was no significant difference between Ufi Gel $C^{(R)}\;and\;Tokuyama^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in modulus of elasticity of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 3 The failure modes of Molloplast $B^{(R)}$ and Ufi Gel $C^{(R)}$ were mainley adhesive type and that of $Tokuyama^{(R)}$ was mainly mixed type in case of nonthermocycling and cohesive type after thermocycling. 4. The water sorption of each soft liners was within ${\pm}2%$ in times (p<0.05) but. there was no significant difference among the soft liners in times.

  • PDF

Biaxial flexural strength and phase transformation of Ce-TZP/$Al_2O_3$ and Y-TZP core materials after thermocycling and mechanical loading

  • Gungor, Merve Bankoglu;Yilmaz, Handan;Aydin, Cemal;Nemli, Secil Karakoca;Bal, Bilge Turhan;Tiras, Tulay
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.224-232
    • /
    • 2014
  • PURPOSE. The purpose of the present study was to evaluate the effect of thermocycling and mechanical loading on the biaxial flexural strength and the phase transformation of one Ce-TZP/$Al_2O_3$ and two Y-TZP core materials. MATERIALS AND METHODS. Thirty disc-shaped specimens were obtained from each material. The specimens were randomly divided into three groups (control, thermocycled, and mechanically loaded). Thermocycling was subjected in distilled water for 10000 cycles. Mechanical loading was subjected with 200 N loads at a frequency of 2 Hz for 100000 times. The mean biaxial flexural strength and phase transformation of the specimens were tested. The Weibull modulus, characteristic strength, 10%, 5% and 1% probabilities of failure were calculated using the biaxial flexural strength data. RESULTS. The characteristic strengths of Ce-TZP/$Al_2O_3$ specimens were significantly higher in all groups compared with the other tested materials (P<.001). Statistical results of X-ray diffraction showed that thermocycling and mechanical loading did not affect the monoclinic phase content of the materials. According to Raman spectroscopy results, at the same point and the same material, mechanical loading significantly affected the phase fraction of all materials (P<.05). CONCLUSION. It was concluded that thermocycling and mechanical loading did not show negative effect on the mean biaxial strength of the tested materials.

The effects of cement thickness and cement shade on the final color of lithium disilicate crowns

  • Yigit Yamali;Merve Bankoglu Gungor;Secil Karakoca Nemli;Bilge Turhan Bal
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권2호
    • /
    • pp.93-100
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the effect of resin cement color, cement thickness, and thermocycling on the final color of monolithic lithium disilicate crowns. MATERIALS AND METHODS. A total of ninety prepared central incisors of typodont teeth were restored with lithium disilicate crowns which have different cement thicknesses (40 ㎛, 80 ㎛, and 120 ㎛) and cement shades (clear, yellow, and white). Color parameters of restorations were measured with a spectrophotometer in three different steps 1) before cementing 2) after cementing and 3) after thermocycling with 10000 cycles. Color differences (ΔE00) were calculated with the CIEDE2000 formula and evaluated according to perceptibility (0.8) and acceptability (1.8) thresholds. The ΔE00 data were analyzed by using two-way ANOVA before and after thermocycling (α = .05). RESULTS. There was no interaction between the cement shade and the cement thickness factors. After cementation, the mean ΔE00 was under the perceptibility threshold in the group of 40 ㎛ cement thickness and clear cement while it was between the perceptibility and acceptability thresholds (0.8 < ΔE00 < 1.8) for all other groups. After thermocycling, the ΔE00 values were between the perceptibility and acceptability thresholds for all experimental groups. Although there were no significant differences among the groups, thermocycling increased the color difference values. CONCLUSION. The cementation of restorations with clear, yellow, and white resin cements resulted in color differences with uncemented restorations except for the group cemented with clear cement in 40 ㎛ cement thickness. All study groups revealed perceptible color change after thermocycling.

도재라미네이트 접착용 레진시멘트의 색조 안정성에 관한 연구 (A STUDY ON THE COLOR STABILITY OF RESIN CEMENTS LUTED FOR PORCELAIN LAMINATE VENEER)

  • 김영운;박하옥;방몽숙;양홍서;박상원
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.191-202
    • /
    • 2007
  • Statement of problems: Long-term success of esthetic restorations, depends on various factors, especially on color stability of the restorations. The color stability is affected by resin cements beneath the porcelain laminate veneers. Purpose: The purpose of this study was to comprehend the color stability of resin cements by comparing with 4 different kinds of resin cements (Choice, Variolink II, Nexus 2, Rely-X). Material and methods: Porcelain laminate disk samples were luted with resin cements. After thermocycling of each 1000, 2000 and 3000 cycle, specimens were measured by spectrophotometers and the color differences were. Results: 1. After thermocycling of 1000, 2000 and 3000cycle, color difference, $({\Delta}E^*)$ of all specimens were incresed, but were not statiscally significant differences. 2. In the Choice of A1 shade and the Nexus 2 of A3 shade, color difference$({\Delta}E^*)$ after thermocycling of 3000cycle was $incre^*ased$ significantly than after thermocycling of 1000cycle. However, other groups did not show any statistically significant differences (P<0.05). 3. After thermocycling of 3000cycle, color difference$({\Delta}E^*)$ between A1 shade and A3 shade of Nexus 2 showed statistically significant difference. However no statistically significant differences were observed in other groups (P<0.05). 4. The mean of color difference$({\Delta}E^*)$ is 1.0-2.06 after 3000 thermocycling and the data were ranked in the ascending order of Variolink II, Nexus 2, Choice and Rely-X in A1 shade group and Choice, Rely-X, Variolink II and Nexus 2 in A3 shade group. Conclusion: Above results revealed that, after 3000 thermocycing, the color difference $({\Delta}E^*)$ of experimental resin cements was within clinically acceptable ranges. Color stability of 4 different resin cements was comparatively excellent.

복합레진, 자이오머, 컴포머의 열순환 후 압축강도와 미세경도의 변화 (CHANGES OF COMPRESSIVE STRENGTH AND MICROHARDNESS OF COMPOSITE RESIN, GIOMER AND COMPOMER AFTER THERMOCYCLING TREATMENT)

  • 윤미;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제37권4호
    • /
    • pp.438-444
    • /
    • 2010
  • 자이오머는 불소를 유리하는 최근 개발된 광중합 레진 제재이다. 본 실험에서는 복합레진, 자이오머, 컴포머를 이용하여 $5^{\circ}C$$55^{\circ}C$에서 5000번 열순환 후 압축강도와 미세경도 변화를 비교 평가하였다. 1. 열순환 전.후 모두 압축강도는 복합레진이 가장 높았으며, 자이오머, 컴포머 순으로 낮아졌다. 복합레진은 자이오머, 컴포머와 통계학적으로 유의차를 보였고(p<0.05), 자이오머와 컴포머 사이에는 유의차가 없었다. 2. 열순환 전.후 미세경도는 복합 레진, 자이오머, 컴포머 순으로 낮아졌으며, 각각 통계학적으로 유의차를 보였다(p<0.05). 3. 복합레진, 자이오머, 컴포머는 열순환 후 통계학적으로 유의하게 미세경도가 감소하였다(p<0.05). 이상의 결과를 종합해보면, 자이오머는 컴포머보다 높은 미세경도를 보이지만, 복합레진보다 낮은 압축강도와 미세경도를 보인다. 열순환 후 미세경도가 감소하므로 임상적 사용시 물리적 성질에 대한 충분한 고찰이 필요할 것으로 사료된다.

Thermocycling이 첨상용 레진과 금속 의치상간의 전단결합강도에 미치는 영향 (The Effects of Thermocycling on the Shear Bond Strength between Metal Denture Base and Relining Resin)

  • 이준석
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose: Recently, various metal primers have been developed, and these are known to increase the bond strength between metal and relining resin. In this study, the change in bond strength according to amount of thermocycling was evaluated. Materials and Methods: In this study, 216 specimens were fabricated. Tokuyama Rebase $II^{(R)}$(Tokuyama Corp., Japan) and $Kooliner^{(R)}$(GC America Inc., Japan) as relining material, and MR. $Bond^{(R)}$(Tokuyama Corp., Japan) and Alloy $Primer^{(R)}$(Kuraray Medical Inc., Japan) as a metal primers were used. Using Ni-Cr and various metal surface treatment methods, resin was bonded and the change in bond strength during thermocycling was measured. The data was analyzed by one-way ANOVA, t-test(p<.05 level of significance). Results: When comparing the groups with only sandblasting, rapid decrease in shear bond strength could be seen. In the groups using Tokuyama Rebase $II^{(R)}$, with the exception of the 1000 and 2000 cycle groups, each group showed statistically significant decrease in shear bond strength(p<0.05). In comparison according to relining materials, $Kooliner^{(R)}$ showed higher shear bond strength than Tokuyama Rebase $II^{(R)}$ in all groups. In groups using MR $bond^{(R)}$, $Kooliner^{(R)}$ had higher shear bond strength than Tokuyama Rebase $II^{(R)}$ but, there was no statistical significance(p<0.05). In the other groups, $Kooliner^{(R)}$ showed significantly higher shear bond strength(p<0.05). There was significant difference between groups with sandblasting and metal primer treatments(p<0.05). In comparison according to metal primer materials, Alloy $Primer^{(R)}$ showed the highest shear bond strength but there was no statistical significance(p>0.05). According to the number of thermocycling cycles, when using Tokuyama Rebase $II^{(R)}$, there were no significant differences between the 0, 1000 and 2000 cycle groups regardless of the type of metal primer. There were no differences between the 2000 and 3000 cycle groups. When using $Kooliner^{(R)}$, regardless of the type of metal primer, there were no significant differences between the 0, 1000, 2000 and 3000 cycle groups(p>0.05). Conclusion: The use of metal primers showed increase in bond strength, and the stability after to thermocycling has been authenticated. Thus, the use of metal primers in relining and rebasing of metal frameworks is essential. But when selecting the material various physical properties should be considered.