Thermo-Visual Evaluations of Acute Abdomen Pain in Children

  • Aleck Ovechkin;Kyeong-Seop Kim;Jeong-Whan Lee;Sang-Min Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.59-64
    • /
    • 2002
  • About two thirds of patients admitted to hospitals world-wide suffer from acute abdomen pains of varying degrees of severity. Acute abdomen pain due to appendicitis or pancreatitis usually requires urgent surgical treatment, whereas pain due to heart ischemia or enteroviral infection requires only drug treatment. In general, making an immediate decision about whether or not acute abdomen pain requires urgent surgery is very difficult. This decision becomes even more difficult when the patient is a young child who can't properly describe the abdominal pain. In this case, thermo-visual inspection can alternatively be used to decide whether urgent surgical treatment is necessary to cure the abdominal pain.

  • PDF

A Study on Visibility Impairment Impact of the Plume from a Vast Point Source (거대 점 오염원의 플룸에 의한 시정 장애 효과 연구)

  • 배주현;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.599-611
    • /
    • 1999
  • Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.

  • PDF

A Case Study of 13 Patients with Lateral Epicondylitis of Elbow Using Deep Thermo-conductive Acupuncture Therapy (심부가열침술을 이용한 주관절 외상과염 환자 치험 13례)

  • Kim, Chae Weon;Park, Hae In;Lee, Yong Hyun;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.30 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Objectives : The Purpose of this study is to evaluate the effect of the deep thermo-conductive acupuncture therapy for the patients with lateral epicondylitis of the elbow. Methods : Thirteen patients with lateral epicondylitis were included from April 2011 to December 2012 and all the patients were treated with the deep thermo-conductive acupuncture therapy. Then we checked visual analog scale(VAS) scores of the patients at every hospital visit, and compared the differences for before and after treatment. We also divided them into 3 age groups(in 40s, 50s, 60s) and 4 groups of the duration of illness(~1 week, ~1month, ~6 months, 6 months ~), and compared the effects for 3 age groups as well as 4 groups of duration of illness. Results : 1. VAS scores had been changed significantly from $6.0769{\pm}1.5390$ to $3.3077{\pm}1.9207$(p=0.005). 2. No significant differences were found between 3 age groups(p=0.968) as well as 4 groups of the duration of illness(p=0.724). Conclusions : This study suggests that deep thermo-conductive acupuncture therapy is effective for healing of the lateral epicondylitis of elbow. But the age and the duration of illness seem to have no influence on results.

Low Power IR Module Design for Small Arms Using Un-cooled Type Detector (비냉각 검출기를 이용한 소화기용 저전력 열상모듈 설계)

  • Sung, Gi-Yeul;Kwak, Dong-Min;Kwak, Ki-Ho;Kim, Do-Jong;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.138-144
    • /
    • 2007
  • This paper introduces the design techniques of an IR module using the 2-D array un-cooled type infrared detector which is applied to the individual combat weapon. Considering the size and weight of the hand carried weapon system, we used a very small-sized detector and applied an adaptive temperature control algorithm so that the operation consumed with low power can be possible. We applied the AR(Auto Regressive) filter to improve the signal-to-noise ratio in a thermal image processing step. We also applied the plateau equalization and boundary enhancement techniques to improve the visibility for human visual system.

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

Development of Concurrent Engineering System for Design of Composite Structures (복합재 구조물의 설계를 위한 동시공학 시스템의 개발)

  • ;;;H.T.Hahn
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.43-52
    • /
    • 1999
  • This paper explains the development of a concurrent engineering system for the rlesign of composite structures. The concurrent engineering system is developed to meet the demand for the better quality products with lower production cost and time. In this study, to compose the architecture of concurrent engineering system, the commercial and noncommercial programs related to design and analysis of composite structures are surveyed and classified. The concurrent engineering system is including various design modules such as design/analysis of composite structures using CLPT and FEM, buckling and post bucking analysis, thermo-elastic analysis of carbon-carbon composite, and optimum design using expert system and genetic algorithm. For the integration and management of softwares, the concurrent engineering system is realized by Microsoft visual $C++{^\circledR}$ that provide multi-tasking and graphic user interface environment.

  • PDF

Influence of mineral by-products on compressive strength and microstructure of concrete at high temperature

  • Sahani, Ashok Kr.;Samanta, Amiya K.;Roy, Dilip K. Singha
    • Advances in concrete construction
    • /
    • v.7 no.4
    • /
    • pp.263-275
    • /
    • 2019
  • In the present work, Granulated Blast Furnace Slag (GBFS) and Fly ash (FA) were used as partial replacement of Natural Sand (NS) and Ordinary Portland Cement (OPC) by weight. One control mix, one with GBFS, three with FA and three with GBFS-FA combined mixes were prepared. Replacements were 50% GBFS with NS and 20%, 30% and 40% FA with OPC. Preliminary investigation on development of compressive strength was carried out at 7, 28 and 90 days to ensure sustainability of waste materials in concrete matrix at room temperature. After 90days, thermo-mechanical study was performed on the specimen for a temperature regime of $200^{\circ}-1000^{\circ}C$ followed by furnace cooling. Weight loss, visual inspection along with colour change, residual compressive strength and microstructure analysis were performed to investigate the effect of replacement of GBFS and FA. Although adding waste mineral by-products enhanced the weight loss, their pozzolanicity and formation history at high temperature played a significant role in retaining higher residual compressive strength even up to $800^{\circ}C$. On detail microstructural study, it has been found that addition of FA and GBFS in concrete mix improved the density of concrete by development of extra calcium silicate gel before fire and restricts the development of micro-cracks at high temperature as well. In general, the authors are in favour of combined replacement mix in view of high volume mineral by-products utilization as fire protection.

A Study on the Cold Pad Batch Dyeing of a String Wallcovering with Reactive Dyestuff (반응성염료를 이용한 스트링벽지 패딩염색에 관한 연구)

  • Lee, Joonhan;Kang, Youngwoong;Kim, Sunmee
    • Journal of Fashion Business
    • /
    • v.21 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • A string wallcovering is a kind of textile wallcovering which is made of cellulose fiber yarn laminated on base paper. Compared with normal paper or PVC wallpaper, a string wallcovering is preferred continually in the interior design market, as it is not only environmentally friendly but it also has less cost on mass production without the weaving process and has a natural visual effect, excellent functionality such as thermo keeping, permeability, sound absorption. However, in the dyeing process, it is not appropriate to use plenty of energy such as water, electricity, steam or chemicals considering the environmental trend and the government policy plenty of energy such as water, electricity, steam or chemicals. Currently, a string wallcovering is made of raw white yarn and padding with direct dye or pigment which includes toxic elements, especially the use of direct dye is restricted in a part of the developed country due to inclusion of azo. In this study, we researched dyeing based on cold pad batch dyeing of a string wallcovering with reactive dyestuff. The peel strength and bending depth test confirmed that the optimum adhesive type and spread amount improved the water resistance of the string wallcovering. Also, pad batch dyeing with optimum reactive dyestuff enhanced the color fastness to light and rubbing in dry and wet conditions. Additionally, for improvement of color fastness to rubbing in a wet condition, the additional treatment finishing without soaping process which is used water. The results of this study can be used as basic data for environmentally friendly and energy saving of the textile wallcovering.