Assessment of temperature effect in structural health monitoring with piezoelectric wafer active sensors

  • Kamas, Tuncay;Poddar, Banibrata;Lin, Bin;Yu, Lingyu
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.835-851
    • /
    • 2015
  • This paper presents theoretical and experimental evaluation of the structural health monitoring (SHM) capability of piezoelectric wafer active sensors (PWAS) at elevated temperatures. This is important because the technologies for structural sensing and monitoring need to account for the thermal effect and compensate for it. Permanently installed PWAS transducers have been One of the extensively employed sensor technologies for in-situ continuous SHM. In this paper, the electro-mechanical impedance spectroscopy (EMIS) method has been utilized as a dynamic descriptor of PWAS behavior and as a high frequency standing wave local modal technique. Another SHM technology utilizes PWAS as far-field transient transducers to excite and detect guided waves propagating through the structure. This paper first presents how the EMIS method is used to qualify and quantify circular PWAS resonators in an increasing temperature environment up to 230 deg C. The piezoelectric material degradation with temperature was investigated and trends of variation with temperature were deduced from experimental measurements. These effects were introduced in a wave propagation simulation software called Wave Form Revealer (WFR). The thermal effects on the substrate material were also considered. Thus, the changes in the propagating guided wave signal at various temperatures could be simulated. The paper ends with summary and conclusions followed by suggestions for further work.

딤플 튜브형 EGR Cooler 구조건전성 및 열효율 평가 (Evaluation of Structural Integrity and Heat Exchange Efficiency for Dimpled Tube Type EGR Cooler)

  • 서영호;이현민;박중원;구태완;김정;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.554-559
    • /
    • 2008
  • Most of vehicle manufacturers have applied exhaust gas recirculation (EGR) system to the development of diesel engines in order to obtain the high thermal efficiency without $NO_X$ and Particulate Matter (PM) emitted from the engine. EGR system, which reflow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine, has been used to solve this problem. In order to confirm the safety of the EGR system, finite element analysis was carried out. The safety of EGR system against temperature variation in the shell and tubes was evaluated through the thermal and structural analysis, and the modal analysis using ANSYS was also performed. Finally, the performance of EGR system was verified through the experiment and numerical simulation using effectiveness-NTU method. Program for the estimation of the heat exchange efficiency of the EGR system with regard to the dimpled tube shape was developed.

  • PDF

Molecular Dynamics Simulation of Liquid Alkanes III. Thermodynamic, Structural, and Dynamic Properties of Branched-Chain Alkanes

  • 이송희;이홍;박형숙
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권5호
    • /
    • pp.501-509
    • /
    • 1997
  • In recent papers[Bull. Kor. Chem. Soc. 1996, 17, 735; ibid 1997, 18, 478] we reported results of molecular dynamics (MD) simulations for the thermodynamic, structural, and dynamic properties of liquid normal alkanes, from n-butane to n-heptadecane, using three different models. Two of the three classes of models are collapsed atomic models while the third class is an atomistically detailed model. In the present paper we present results of MD simulations for the corresponding properties of liquid branched-chain alkanes using the same models. The thermodynamic property reflects that the intermolecular interactions become weaker as the shape of the molecule tends to approach that of a sphere and the surface area decreases with branching. Not like observed in the straight-chain alkanes, the structural properties of model Ⅲ from the site-site radial distribution function, the distribution functions of the average end-to-end distance and the root-mean-squared radii of gyration are not much different from those of models Ⅰ and Ⅱ. The branching effect on the self diffusion of liquid alkanes is well predicted from our MD simulation results but not on the viscosity and thermal conductivity.

목조건축물 구조부재의 열전도율에 따른 건물외피의 단열 성능 (Thermal Performance of Wooden Building Envelope by Thermal Conductivity of Structural Members)

  • 김석환;유슬기;서정기;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.515-527
    • /
    • 2013
  • 국내에서 주로 사용되고 있는 건물에너지 성능평가 시뮬레이션 마다 상이한 재료의 열전도율로 평가 되고 있음이 파악되었다. 시뮬레이션을 통한 정확한 건물에너지부하를 평가하기 위하여, 각 시뮬레이션에서 목조건축물의 스터드로 사용되고 있는 목재의 열전도율을 확인하고, 이에 따른 벽체의 열관류율과 부재 접합부위에서의 선형열교 차이를 연구하였다. 각 시뮬레이션은 동일 수종에 대해 상이한 열전도율을 채택 후, 각 시뮬레이션에서 추출한 열전도율 간의 차이가 가장 상이한 소나무의 열전도율을 스터드에 적용하였다. 시뮬레이션 간 지붕, 벽체, 지면 슬래브의 열관류율 중 최대오차는 $0.023W/m^2{\cdot}K$이었으며, 지붕의 서까래 접합부, 지붕-벽체 접합부, 지면슬래브-벽체 접합부 중 최대 선형열교 오차는 $0.025W/m{\cdot}K$이었다. 또한, HEAT2 정상상태전열해석 프로그램을 활용하여 선형열교 및 벽체의 온도변화에 대한 전열해석 이미지를 분석하였다. 구조체에 온도 분포를 선으로 표시하여 단열이 부족한 곳에서는 온도선이 급격하게 변하는 것이 확인되었고, 온도선이 급격하게 변하는 부위에서는 다른 곳보다 온도가 낮으며, 다른 구조체 부분보다 더 많은 열류가 손실됨이 확인되었다.

굴착으로 인한 방사성폐기물 지하처분공동의 거동변화 (A Study on Excavation Responses of Underground Openings for Radioactive Waste Disposal)

  • 김선훈;김대홍;최규섭;김진웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.174-179
    • /
    • 1992
  • In this paper a discussion is presented about excavation responses of underground openings for radioactive waste disposal. The effects of excavation methods, stress redistribution, thermal change, and backfill materials are reviewed. Comparisons of computational models for discontinuous reek masses and discussions on numerical simulation techniques for the excavation of underground openings are also described. Finally, the application of the CAD system to the planning, design and construction of underground openings fop radioactive waste disposal is introduced.

  • PDF

유한 요소 해석을 활용한 직결 주축의 열적 특성 평가 (Evaluation of Thermal Characteristics of a Direct-Connection Spindle Using Finite Element Co-Analysis)

  • 김태원;최진우
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.228-234
    • /
    • 2013
  • This study focuses on development of a finite element model for analysis of thermal characteristics of a direct-connection spindle of a machining center by joint simulation of heat transfer and thermal deformation. Two finite element analyses were carried out procedurally for heat transfer, first, to identify temperature distribution of components of the spindle and then for thermal deformation to identify their structural behavior based on the temperature distribution. It was assumed that the heat transfer between a component revolving and the surrounding air is identical to that between a flat plate and the running air on it and the heat transfer is based on a uniform surface heat flux for turbulent flow. The results from the analyses were compared with those from experiments to validate the finite element model.

용접열사이클 재현에 의한 SS400강 및 STS304강의 특성 평가 -제2보: 부식특성 (Evaluation of Characteristic for SS400 and STS304 steel by Weld Thermal Cycle Simulation - 2nd Report: Corrosion Characteristics)

  • 안석환;최문오;김성광;손창석;남기우
    • 한국해양공학회지
    • /
    • 제21권5호
    • /
    • pp.33-38
    • /
    • 2007
  • The welding methods have been applied in the most structural products from multi-field of automobile, ship construction and construction, and so on. The structure steel must have enough strength of structure. In this study, SS400 steel and STS304 steel were used to estimate the corrosion characteristics of the weld thermal cycle simulated HAZ. To evaluate the corrosion characteristics, also, the materials with two conditions were used in 3.5% NaCl. The one is to the drawing with diameter of ${\Phi}10$ and the other is to the residual stress removal treatment. The electrochemical polarization test and immersion test were carried out. From test results, corrosion potential, corrosion current density, weight loss ratio and corrosion rate were measured. In the kinds of SS400 steels, corrosion potential of weld thermal cycle simulated specimens after the heat treatment showed somewhat the direction of noble potential. And in the base metal to be drawing weight loss ratio and corrosion rate occurred higher than the other kinds. In the kinds of STS304 steels, the result of base metal to be drawing was similar to results of SS400 steels, too. Two kinds of $750^{\circ}C$ and $1300^{\circ}C$ of weld thermal cycle simulation after the heat treatment were rather higher than the other kinds in weight loss ratio and corrosion rate.

Integrated fire dynamics and thermomechanical modeling framework for steel-concrete composite structures

  • Choi, Joonho;Kim, Heesun;Haj-ali, Rami
    • Steel and Composite Structures
    • /
    • 제10권2호
    • /
    • pp.129-149
    • /
    • 2010
  • The objective of this study is to formulate a general 3D material-structural analysis framework for the thermomechanical behavior of steel-concrete structures in a fire environment. The proposed analysis framework consists of three sequential modeling parts: fire dynamics simulation, heat transfer analysis, and a thermomechanical stress analysis of the structure. The first modeling part consists of applying the NIST (National Institute of Standards and Technology) Fire Dynamics Simulator (FDS) where coupled CFD (Computational Fluid Dynamics) with thermodynamics are combined to realistically model the fire progression within the steel-concrete structure. The goal is to generate the spatial-temporal (ST) solution variables (temperature, heat flux) on the surfaces of the structure. The FDS-ST solutions are generated in a discrete form. Continuous FDS-ST approximations are then developed to represent the temperature or heat-flux at any given time or point within the structure. An extensive numerical study is carried out to examine the best ST approximation functions that strike a balance between accuracy and simplicity. The second modeling part consists of a finite-element (FE) transient heat analysis of the structure using the continuous FDS-ST surface variables as prescribed thermal boundary conditions. The third modeling part is a thermomechanical FE structural analysis using both nonlinear material and geometry. The temperature history from the second modeling part is used at all nodal points. The ABAQUS (2003) FE code is used with external user subroutines for the second and third simulation parts in order to describe the specific heat temperature nonlinear dependency that drastically affects the transient thermal solution especially for concrete materials. User subroutines are also developed to apply the continuous FDS-ST surface nodal boundary conditions in the transient heat FE analysis. The proposed modeling framework is applied to predict the temperature and deflection of the well-documented third Cardington fire test.

Experimental analysis of thermal gradient in concrete box girder bridges and effects of polyurethane insulation in thermal loads reduction

  • Raeesi, Farzad;Heydari, Sajad;Veladi, Hedayat
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.645-654
    • /
    • 2022
  • Environmental thermal loads such as vertical and lateral temperature gradients are significant factors that must be taken into account when designing the bridge. Different models have been developed and used by countries for simulating thermal gradients in bridge codes. In most of the codes only vertical temperature gradients are considered, such as Iranian Standard Loads for Bridge code (ISLB), which only considers the vertical gradient for bridge design proposes. On the other hand, the vertical gradient profile specified in ISLB, has many lacks due to the diversity of climate in Iran, and only one vertical gradient profile is defined for whole Iran. This paper aims to get the both vertical and lateral gradient loads for the concrete box girder using experimental analysis in the capital of Iran, Tehran. To fulfill this aim, thermocouples are installed in experimental concrete segment and temperatures in different location of the segment are recorded. A three dimensional finite element model of concrete box-girder bridge is constructed to study the effects of thermal loads. Results of investigation proved that the effects of thermal loads are not negligible, and must be considered in design processes. Moreover, a solution for reducing the negative effects of thermal gradients in bridges is proposed. Results of the simulation show that using one layer polyurethane insulation can significantly reduce the thermal gradients and thermal stresses.