• 제목/요약/키워드: thermal sensation

검색결과 286건 처리시간 0.021초

손의 한랭자극이 인체생리반응과 의복의 쾌적성에 미치는 영향 -한랭혈관반응, 온랭감각, 한랭통증을 중심으로- (Effect of Cooling Hands in the Cold Water for the Physiological Responses and Clothing Comfort -Focused on Vascular Hunting Reaction, Thermal Sensation and Pain Sensation-)

  • 이원자
    • 복식문화연구
    • /
    • 제12권2호
    • /
    • pp.279-289
    • /
    • 2004
  • This study was conducted to compare the hunting reaction of finger in the cold water. Finger skin temperature is measured the left middle finger tip immersion in cold water of 5℃ for 30 minutes and measurements were made on finger skin temperature(Ts), thermal comfort, and cold pain sensations during the experiment at the spring (March) and Winter(December). Results were follows. Is before immersion was at the highest in spring and at the lowest in winter and was closely related to the indoor temperature Ts during immersion and recovery. Mean of finger skin temperature(MST), the skin temperature at the first rise(TTR) and amplitude of finger skin temperature reaction during immersion(AT) were significant higher in spring than that in winter(P<.01). The lowest skin temperature(LST) during the cold water immersion were significantly higher in spring than that in winter (P<.05). The frequency of the appearance of cold-Induced vase dilation(CIVD) was higher in spring than that in winter. However, time for the first temperature(TTR) and recovery time(RT) had no seasonal variation. In addition, cold pains during immersion were felt more strongly in spring than in winter. Local thermal sensation, finger thermal sensation in dynamic state during hand immersion was different from that in the Winter. Spring was slowly cold in cold water immersion.

  • PDF

남한의 연 누적 온습도 지수에 따른 생리기후유형의 특성 (The Characteristics of Bioclimatic Types According to Annual Cumulative Temperature-Humidity Index in South Korea)

  • 강철성
    • 대한지리학회지
    • /
    • 제43권3호
    • /
    • pp.312-323
    • /
    • 2008
  • 본 논문에서는 인간 생활에 기본이 되는 온도, 상대습도를 기초로 하여 인간의 온열감을 측정하여 남한의 온열감 분포의 특성과 기후유형을 파악하였다. 연구 방법은 설문지 검사를 통하여 온습도 지수 공식을 이용, 월별 온열감, 연 누적 온열감 지수를 계산하였다. 월별 온열감 지수 분석 결과 온열감의 지역적 차이는 위도 및 고도, 지형적 요인, 기단체계에 따른 영향으로 나타났다. 연 누적 온열감 지수분포는 대체로 남쪽에서 북쪽으로 갈수록, 해안에서 내륙으로 갈수록 기후 스트레스가 증가하였다. 이러한 원인으로 겨울의 추위 스트레스와 여름의 더위 스트레스가 높기 때문에 나타나는 현상으로 사료된다. 연 생리 기후유형은 쾌적함(M)기후유형, 극히 무더움(ES)유형, 쾌적함-극히 무더움(M-ES)유형, 쾌적함-무더움(M-S)유형, 더움-극히 무더움(W-ES)유형, 서늘함-극히 무더움(C-ES)유형, 서늘함-쾌적함(C-M)유형, 서늘함-쾌적함-극히 무더움(C-M-ES)유형으로 도합 8개의 기후유형으로 구분된다.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

대구지역 동계 제복 근무자의 피복 착의 앙상블과 쾌적성의 주관적 평가 (The Subjective Estimation on the Ensemble and Comfort of Workers Wearing winter Uniform in Taegu)

  • 류덕환;이옥자;김승진;송민규;조지현;정명선
    • 한국의류산업학회지
    • /
    • 제2권3호
    • /
    • pp.253-264
    • /
    • 2000
  • The purpose of this study was to examine the thermal comfort characteristics of the garments for school, textile and bank worker's uniform. The garments selected for this study were frequently used in Taegu area in terms of design and material used for making garments by the survey for the study The human subject tests were performed to determine the thermal comfort characteristics of garments including thermal, humidity, and wearing sensation and the data were analysed statistically. The results of the study were as follows: 1. According to the result of the survey jacket was mostly used as a school uniform for both male and female high school students. The survey showed that 93% of male students wore 'neck T-shirts' and dimensional fitness for the school uniform got suitable at 2~3 grade high school students. In terms of human subject tests, most students rated 'uncomfortable' in wearing sensation of their school uniform. One of this reason was due to the humidity sensation and air velocity sensation. Level of significance of the thermal sensation for gender difference was higher in hands and feet of the subjects than in chest and thigh of them. 2. According to the result of the survey jacket with zipper was mostly used as a textile worker's uniform. The result of the survey indicated that some textile workers are wearing their inner wear (38.7% for upper and 46.6% for lower). In the human subject tests, about 50% of subjects rated 'comfortable to slightly comfortable' for wearing sensation of the textile worker's uniform. It showed that the female subjects of the humidity sensation was rated higher than the male subjects of the humidity sensation, while the male subjects of the thermal sensation was rated higher than the female subjects of the thermal sensation. There was a closer correlation with the subjective thermal sensation for textile worker's uniform in center parts of the subjects such as back and waist than exposed parts. 3. The result of the survey showed that 70% and 23% of the female banker uniform were blouse and jacket, respectively and 75% and 25% of the male banker uniform were jacket and T-shirt, respectively. All interviewee rated trousers and skirts that were used for their lower. 4. The result indicated that 50% male and 67.7% female subjects for the banker uniform rated 'slightly comfortable for the comfort' sensation. 50% male subjects rated 'neutral' and about 50% female subjects rated 'slightly warm to neutral' for the thermal sensation. In addition, The result showed that 75% male subjects for both upper and lower rated 'neutral' for the humidity sensation and also 75% female subjects rated 'neutral to slightly dry'. Thus, there was no significant different between gender. 5. In the thermal sensation of the subjects for the banker's uniform by parts, 50% subjects rated 'neutral' for their body parts, including head, neck, back, waist, hip, lower arm, and thigh. The extremely cold parts were hands and feet for both male and female subjects.

  • PDF

겨울철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Winter)

  • 배귀남;이철희;이춘식;최항철
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.310-318
    • /
    • 1995
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 138 occupants were questioned to evaluate Korean thermal comfort in office building in winter. Thermal sensation was estimated by using PMV(Predicted Mean Vote) and ET*(New Effective Temperature) indices. Comparing present experimental result with international standards and that of other research, Korean thermal responses were discussed. Seasonal difference between summer and winter was also discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained; TSV=0.432ET*-8.814 and neutral temperature is $20.4^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $19.4{\sim}22.4^{\circ}C$.

  • PDF

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

남녀 중학생의 겨울철 교실 내 한서감과 기후적응성 (Thermal Sensation in Winter Classroom and Cold Climate Adaptability of Junior High School Students)

  • 조아름;심현섭
    • 한국의류산업학회지
    • /
    • 제20권6호
    • /
    • pp.744-751
    • /
    • 2018
  • This study aimed to provide the information on the thermal sensation and the amount of clothing worn of junior high school students in winter classroom the relation with their climate adaptability. Total usable questionnaires were obtained from 467 male and female students. The questionnaire included general characteristics, physical characteristics, self awareness of body shape, climate adaptability and subjective thermal sensation in winter classroom. The data were analyzed using SPSS Statistics 18.0 for frequency analysis, factor analysis, chi-square analysis, t-test and correlation analysis. The results were as follows. The average body type based on BMI was normal($20.1kg/m^2$ ). Females perceived their body type as thinner than males. They wore more (8.67 garment items compared to 8.14 for males). Only about 25% of students voted the thermal sensation to neutral(47% cool~very cold, 28% warm~very hot). Females were more sensitive to the cold, perceived less healthy, and wore more garments in the cold. Students felt colder in winter classroom when their cold adaptability was lower and they actively adjusted thermal insulation against the cold. It is recommended to suggest the guidelines for the proper indoor temperature and for the wear behavior in classroom in the perspectives of increasing the learning efficiency and improving the students' climate adaptability.

실내 난방시 온열쾌적성 평가에 관한 연구(part I;실내 난방시 실온변화에 따른 감성이미지 평가) (Experimental Study on Thermal Sensation Evaluation in Heating(part I: Emotion & Sensibility Image Evaluation by Indoor Temperature Change in Heating))

  • 한남규;금종수;김형철;김동규;김창연
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2003년도 춘계학술대회 논문집
    • /
    • pp.41-46
    • /
    • 2003
  • In recently, Is inhabiting more than 70% indoors during a day in case of company employee and ordinary people which is looking at usual business. Therefore Thermal comfort of human body about indoor temperature and air flow acting very heftily. When intestine temperature is fallen for external low temperature and air flow in winter in case enter into heated room feel comfort by effect of temperature and feel comfort or discomfort by room heating condition gradually. Therefore it is important that grasp thermal comfort about temperature and air flow in heating to keep continuous comfort in indoor dwelling. Temperature and thermal comfort factor of emotion & sensitivity image exert fair effect since heating middle although thermal comfort change greatly effect on sensation about temperature at actuality heating early. Need much study yet in vantage point of emotion & sensitivity although much study were held about thermal and comfort sensibility and when heat in existing research until now. Therefore this study is targeting that evaluate thermal comfort through introduction of estimation method by emotion & sensibility image real and synthetic sensibility about thermal environment that is becoming winter heating.

  • PDF

여름철 냉방실내의 적정착의량에 관한 연구 (A Study on the Optimal Clothing Weight in an Air Conditioned Office in Summer)

  • 김선영;이순원
    • 한국의류학회지
    • /
    • 제9권3호
    • /
    • pp.45-51
    • /
    • 1985
  • The purpose of this study is to research into the thermal condition and the weight of clothes suitable for the officers engagged in light works in an air-conditioned room in summer. The Major findings are as follows: 1. Thermal conditions of the working environment are $24.5^{\circ}C$ (Dry bulb temp.), $68\%$ (Relative humidity) and 2.6m/sec (Air Velocity). 2. Total clothing weights are 416.6 g/$m^2$ (male) and 340.9 g/$m^2$ (female). Underwear weights are 96.8g/$m^2$ (male) and 85.1g/$m^2$ (female). The latter turned out to be statistically significant in Sexual difference. 3. Means of the thermal sensation are 3.0 (comfortable; male) 2.7 ('Slightly cool' -'Comfortable'; female) and the relationship between clothing weights and thermal sensation proves to be significantly correlated in the case of female. 4. $66.7\%$ of the women and $37.1\%$ of the men feel sensation of coldness at the body's specific area and $79.5\%$ of the women and $54.3\%$ of the men reveals air-conditioning disturbance. 5. As the thermal sensation is close to 'cool-cold', sensation of coldness or air conditioning disturbance are showed up more frequently which is reversely related with weight of under-wear. It is also proved that air conditioning disturbances are influenced by sexual difference in addition to sensation of coldness and thermal sensation. 6. According to the result of experiment, we can have the idea that at condition $X_1$, the drop of limbs' skin temp. is remarkable. At condition $X_2$ skin temp. for distal limbs and mean skin temp. are raised and the falling degree is similar. At condition $X_3$, mean skin temp. and distal skin temp. are remarkably raised, and the falling degree decreases and the beats of pulse rate increase and diastoric blood pressure is lowered.

  • PDF

체형특성(體型特性)이 체온조절반응(體溫調節反應) 및 온열쾌적감(溫熱快適感)에 미치는 영향(影響) (Effects of Somatotype Characteristics on Body Temperature Control Reaction & Thermal Sensation)

  • 심부자;유현
    • 패션비즈니스
    • /
    • 제7권1호
    • /
    • pp.27-37
    • /
    • 2003
  • This study is the first part of the research to reveal the effects of somatotype characteristics on body temperature control reaction as well as thermal sensation. Nine healthy female collegians (classified into 3 body types of thin, normal, and obese according to Rohrer index) living in Busan were chosen as the subjects. The following are the results: Significant differences of skin temperature appeared in the parts of epigastrium (thin/normal>obese), anterior forearm (normal>thin/obese), and anterior leg (obese > thin/normal) as well as mean skin temperature. Mean skin temperature temporarily dropped owing to the exercise but tended to recover as time went by. Skin temperature of normal/thin shows higher than obese type. The change of skin temperature was noticed in the order of forehead > epigastrium > anterior forearm > anterior leg > anterior thigh (obese type) ; epigastrium > forehead > anterior forearm > anterior thigh > anterior leg (normal type) ; epigastrium > forehead > anterior forearm > anterior thigh > anterior leg (thin type, before and after exercise); epigastrium > forehead > anterior forearm > anterior leg > anterior thigh (thin type, during exercise). Significant differences were shown in the temperature change inside clothes according to somatotypes. No significant differences were revealed in thermal sensation, moisture sensation, and comfortable sensation according to body types and time.