• 제목/요약/키워드: thermal load

Search Result 1,838, Processing Time 0.024 seconds

A Experimental Study on the Effects of the Impingement-wall on the Spray and Combustion Characteristics of Direct-Injection LPG (충돌벽면이 직분식 LPG의 분무 및 연소 특성에 미치는 영향에 관한 실험 연구)

  • Hwang, Seong-Ill;Chung, Sung-Sik;Yeom, Jeong-Kuk
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • As an alternative fuel that can be used in SI engine, LPG is one of clean fuels with larger H/C ratio compared to gasoline, low $CO_2$ emission, and small amount of pollutants such as sulfur compounds. When LPG is used in spark ignition engine, volumetric efficiency of the engine can be improved and pumping loss can be reduced by performing direct injection into the combustion chamber instead of port fuel injection. LPG-DI engine allows for lean combustion and stratified combustion under low load. In case of stratified combustion, air fuel ratio can be greatly increased compared to theoretic mixture ratio combustion. Improved thermal efficiency of the engine and reduced pumping loss can be expected from stratified combustion. Accordingly in this study, an experimental apparatus for visualization was designed and manufactured to study the combustion process of LPG after injection and ignition, intended to examine ignition probability and combustion characteristics of spark ignition direct injection(SIDI) LPG fuel. Ambient pressure, ambient temperature and fuel injection pressure were found as important variables that affect ignition probability and flame propagation characteristics of LPG-air mixture. Also, it was verified that the injected LPG fuel can be directly ignited by spark plug under appropriate ambient conditions.

Development of Large Superalloy Exhaust Valve Spindle by Dissimilar Inertia Welding Process (이종재료 마찰용접에 의한 초내열합금 대형 배기밸브 스핀들 개발)

  • Park Hee-Cheon;Jeong Ho-Seung;Cho Jong-Rac;Lee Nak-Kyu;Oh Jung-Seok;Han Mvoung-Seoup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.891-898
    • /
    • 2005
  • Inertia welding is a solid-state welding process in which butt welds in materials are made in bar and in ring form at the joint race, and energy required lot welding is obtained from a rotating flywheel. The stored energy is converted to frictional heat at the interface under axial load. The quality of the welded joint depends on many parameters, including axial force, initial revolution speed and energy amount of upset. working time, and residual stresses in the joint. Inertia welding was conducted to make the large exhaust valve spindle for low speed marine diesel engine. superalloy Nimonic 80A for valve head of 540mm and high alloy SNCrW for valve stem of 115mm. Due to different material characteristics such as, thermal conductivity and flow stress. on the two sides of the weld interface, modeling is crucial in determining the optimal weld geometry and Parameters. FE simulation was performed by the commercial code DEFORM-2D. A good agreement between the Predicted and actual welded shape is observed. It is expected that modeling will significantly reduce the number of experimental trials needed to determine the weld parameters. especially for welds for which are very expensive materials or large shaft. Many kinds of tests, including macro and microstructure observation, chemical composition tensile , hardness and fatigue test , are conducted to evaluate the qualify of welded joints. Based on the results of the tests it can be concluded that the inertia welding joints of the superalloy exhaust valve spindle are better properties than the material specification of SNCrW.

A Study on the Engine Performance and Emission Characteristics in a LP EGR System with Electronic Throttle Control (ETC를 적용한 저압 EGR시스템의 엔진성능 및 배출가스 특성에 관한 연구)

  • Park, Jun-Heuk;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.379-387
    • /
    • 2011
  • Research and development of LP EGR system for the performance improvement and emission reduction on diesel engine is proceeding at a good pace. LP EGR system seems to be helpful method to further reduce$NO_x$ emissions while maintaining PM emissions at a low level because the boost pressure is unchanged while varying EGR rate. This study is experimentally conducted on a 2.0L common rail DI engine at the medium load condition (2000 rpm, BMEP 1.0 MPa, boost pressure 181.3 kPa) that difficult to use large amount of EGR gas because of deteriorations of performance and fuel consumption. And we investigated the characteristics of performance and fuel consumption while varying EGR systems. The overall results using LP EGR system equipped with ETC identified benefits on reduction of PM and improvement of fuel consumption and thermal efficiency while keep the $NO_x$ level compared to HP EGR and LP EGR with back pressure valve.

Effect of Compression Ratio Change on Emission Characteristics of HCNG Engine (압축비 변화가 수소-천연가스 엔진의 배기특성에 미치는 영향)

  • Lee, Sung Won;Lim, Gi Hun;Park, Cheol Woong;Choi, Young;Kim, Chang Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.473-479
    • /
    • 2013
  • This study focused on a heavy-duty natural gas engine fuelled with HCNG (CNG: 70 vol%, hydrogen: 30 vol%) and CNG. To study the emission characteristics of an HCNG engine with high compression ratio, the exhaust gas of CNG and HCNG fuel were analyzed in relation to the change in the compression ratio at the half load condition. The results showed that the thermal efficiency improved with an increase in the compression ratio. Consequently, $CO_2$ emission decreased. CO emission increased with inefficient oxidation due to the low exhaust gas temperature. $NO_x$ emission with high compression ratio was increased at the same excess air ratio condition. However, $NO_x$ emission was not affected by a compression ratio exceeding ${\lambda}$ = 1.9 because of the same MBT timing.

A Study on the Fire Resistance of yLRC Composite Columns with Steel Sheet Forms and Angles (강재 영구거푸집을 사용한 yLRC 합성기둥의 내화성능 연구)

  • Kim, Bo Ram;Kang, Seong Deok;Kim, Hyung Geun;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.365-375
    • /
    • 2008
  • The main objective of this paper is to study the behaviour of yLRC composite columns at elevated temperatures by experimental test. The effects of load ratios, cross-section size and fire protection for the yLRC columns were investigate d by the test and compared using the heat transfer analysis perfo rmed based on the finite element program ANSYS 10.0 using the ISO834 standard fire curve, following the main guidelines proposed by the EC4 Part 1.2. As heat transfer is the movement of heat by conduction, convection, and radiation, and as temperature inside an object varies by position and time, time. As the steel's thermal conductivity is higher than that of concrete, steel loses its strength rapidly in a high-temperature situation such as a fire. Fire resistance performance of the yLRC composite column under fire conditions was evaluated througheat transfer analysis for parametric study.

The Effects of Hydrogen on DME HCCI Combustion (DME 예혼합 압축착화 엔진에서 수소의 영향)

  • Baek, Cheul-Woo;Yoon, Hyeon-Sook;Yeom, Ki-Tae;Jang, Jin-Young;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.15-21
    • /
    • 2007
  • The aim of this paper is controlling ignition timing and load in homogeneous charge compression ignition (HCCI) combustion with low cetane number fuel, hydrogen. Homogeneous charge compression ignition (HCCI) combustion is an advanced combustion technology that achieves higher thermal efficiency and lower $NO_x$ emissions than that of conventional combustion system. Dimethyl ether (DME), which has been researched widely as the most attractive alternative fuel of diesel, is attractive for HCCI combustion because of the easy evaporation. In this study, the single cylinder DME engine operated with a direct injection system has been used to investigate combustion processes and emissions of DME HCCI with a premixed hydrogen supply. The experiment was carried out under various engine speed and fraction rates of hydrogen. As a result, the increase of fraction rates of hydrogen retard the DME ignition timing and eliminated the knocking during high engine speed condition. IMEP was increased with increase of fraction rates of hydrogen by 30%. 40% of the fraction rates of hydrogen resulted in misfiring. The $NO_x$ emission was reduced by increasing the fraction rates of hydrogen, but HC emission was increased.

Effects of the Freeze-thaw Process on the Strength Characteristics of Soils (IV) -Insulation Performance beneath the Freezed Tested Banking by Inclusion of Insulation Material- (동결-융해작용이 흙의 강도특성에 미치는 영향 (IV) - 단열재를 삽입한 동결성토의 단열거동 -)

  • 유능환;박승범;유영선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.39-46
    • /
    • 1990
  • This paper was analized the thermal conductivity of polystylene (TENSAR- GEOGRID) embeding into the subbase through frost penetration depth, frost heave, change of bearing capacity, and soil moisture movement due to freezing, thawing and icing actions, and their results were as follows : 1.The change of temperature into the sub-base was much increased by the Tensar-Geogrid insertion, and the frost penetration and frost heave were decreased as the thinner of the insulation thickness but the thawing velocity of melting period was appeared to be faster in case of non-insulated. 2.The frost heave had a close relationship with the thickness of insulations which was reasonably included anti-frost effects. 3.The moisture content during the freezing period of upper layer of the insulation insertion was increased by 15 per cent but it was returned to initial state of the thawing period, and at the down layer temporarily increased by 10 per cent and returned to the original state at once. 4.The insulation was acted as a function of distribution of surcharge, and the settlement of the sub-base was about 1.5 mm under 15 tonnage of load and which was included within the allowable limits. 5.The sliding resistance due to the icing which was induced by the insulation insertion into the sub-base was appeared as more 40 per cent than noninsulation area, so that the insulations should be restricted on the place such as mountains, curved and cross area which were required the braking power under the traffics.

  • PDF

Effects of the electronic expansion valve and variable velocity compressor on the performance of a refrigeration system

  • Lago, Taynara G.S.;Ismail, Kamal A.R.;Nobrega, Claudia R.E.S.;Moura, Luiz F.M.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.1-19
    • /
    • 2020
  • Energy consumption of air-conditioning and refrigeration systems is responsible for about 25 to 30% of the energy demand especially in hot seasons. This equipment is mostly electricity dependent and their use in principle affects negatively the environment. Enhancing the energy efficiency of the existing equipment is important as one of the measures to reduce environment impacts. This paper reports the results of an experimental study to evaluate the impacts of the use electronic expansion valve and variable velocity compressor on the performance of vapor compression refrigeration system. The experimental rig is composed of two independent circuits one for the vapor compression system and the other is the secondary fluid system. The vapor compression system is composed of a forced air condenser unit, evaporator, hermetic compressor and expansion elements, while the secondary system has a pump for circulating the secondary fluid, and an air conditioning heat exchanger. The manufacturer's data was used to determine the optimal points of operation of the system and consequently tests were done to evaluate the influence of variation of the compressor velocity and the opening of the expansion device on the performance of the refrigeration system. A fuzzy logic model was developed to control the rotational velocity of the compressor and the thermal load. Fuzzy control model was made in LabVIEW software with the objective of improving the system performance, stability and energy saving. The results showed that the use of fuzzy logic as a form of control strategy resulted in a better energy efficiency.

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

Numerical Analysis of Fiber Reinforced Concrete Base Subjected to Environmental Loads (섬유보강 콘크리트 기층의 환경하중에 대한 거동 수치 해석)

  • Cho, Young-Kyo;Kim, Seong-Min;Park, Jong-Sub;Park, Young-Hwan
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.239-249
    • /
    • 2011
  • The behavior of the fiber reinforced concrete (FRC) base under environmental loads was analyzed numerically as a fundamental study to develop a high structural and functional performance composite pavement system in which the base was formed using FRC and the asphalt or cement concrete surface was placed on it. A two-dimensional finite element model of the FRC base was developed and the sensitivity study was performed with the variables including slab thickness of base, thermal expansion coefficient, elastic modulus, and tensile and compressive strengths. The crack spacing and crack width were selected as representatives of the base behavior. The effects of the selected variables on the crack spacing and crack width were analyzed and the sensitive variables were determined. The results of this study could be useful to determine the optimal material properties of the FRC base for combining well with the surface materials.